A method for patient-specific evaluation of vertebral cancellous bone strength: in vitro validation.

BACKGROUND: In the context of osteoporosis, important determinants of the fracture risk are the apparent strength and stiffness of cancellous bone, as well as its brittleness and energy absorption capacity. Standard medical imaging, however, cannot measure these mechanical properties directly. Consequently, an estimation of the risk for fracture is made by correlating relative density or mineral density at a skeletal site with statistics of fracture occurrence, which provides limited and partial indications on fracture risks. A better method for evaluating the patient-specific mechanical properties of cancellous bone is therefore required. METHODS: In order to asses the mechanical properties of vertebral cancellous bone, we developed a finite element parametric model of lattice trabecular architecture that, in the future, will be suitable for use with bone imaging modalities. The model inputs are apparent morphological parameters (trabecular thickness and trabecular separation) and the bone mineral density. We conducted uniaxial compression tests on 36 canine vertebral cancellous bone specimens (C7 and L1) to validate model predictions of strength and stiffness in vitro. FINDINGS: Predictions of strength and stiffness matched the experimental results within relative absolute errors of 17.7% and 12.8%, respectively (average of differences between model-predicted and measured values, divided by the average of measured values). We also employed the model for evaluation of strength and stiffness of human L1 and L5 vertebrae and found mean strength of 1.67 MPa (confidence interval 0.42 MPa) and mean elastic modulus of 190 MPa (confidence interval 50 MPa), which are well within the range of previously reported apparent strength and stiffness properties. INTERPRETATION: The present model can be used to improve medical imaging-based evaluation of the spine in osteoporotic individuals by providing more specific information on the individual bone's susceptibility to fracture once clinical bone scans will be able to provide more reliable measures of trabecular thickness and separation.

Animals↗

Real-time patient-specific finite element analysis of internal stresses in the soft tissues of a residual limb: a new tool for prosthetic fitting.

Fitting of a prosthetic socket is a critical stage in the process of rehabilitation of a trans-tibial amputation (TTA) patient, since a misfit may cause pressure ulcers or a deep tissue injury (DTI: necrosis of the muscle flap under intact skin) in the residual limb. To date, prosthetic fitting typically depends on the subjective skills of the prosthetist, and is not supported by biomedical instrumentation that allows evaluation of the quality of fitting. Specifically, no technology is presently available to provide real-time continuous information on the internal distribution of mechanical stresses in the residual limb during fitting of the prosthesis, or while using it and this severely limits patient evaluations. In this study, a simplified yet clinically oriented patient-specific finite element (FE) model of the residual limb was developed for real-time stress analysis. For this purpose we employed a custom-made FE code that continuously calculates internal stresses in the residual limb, based on boundary conditions acquired in real-time from force sensors, located at the limb-prosthesis interface. Validation of the modeling system was accomplished by means of a synthetic phantom of the residual limb, which allowed simultaneous measurements of interface pressures and internal stresses. Human studies were conducted subsequently in five TTA patients. The dimensions of bones and soft tissues were obtained from X-rays of the residual limb of each patient. An indentation test was performed in order to obtain the effective elastic modulus of the soft tissues of the residual limb. Seven force sensors were placed between the residual limb and the prosthetic liner, and subjects walked on a treadmill during analysis. Generally, stresses under the shinbones were approximately threefold higher than stresses at the soft tissues behind the bones. Usage of a thigh corset decreased the stresses in the residual limb during gait by approximately 80%. Also, the stresses calculated during the trial of a subject who complained about pain and discomfort were the highest, confirming that his socket was not adequately fitted. We conclude that real-time patient-specific FE analysis of internal stresses in deep soft tissues of the residual limb in TTA patients is feasible. This method is promising for improving the fitting of prostheses in the clinical setting and for protecting the residual limb from pressure ulcers and DTI.

Amputees↗

Real-time subject-specific monitoring of internal deformations and stresses in the soft tissues of the foot: a new approach in gait analysis.

No technology is presently available to provide real-time information on internal deformations and stresses in plantar soft tissues of individuals during evaluation of the gait pattern. Because internal deformations and stresses in the plantar pad are critical factors in foot injuries such as diabetic foot ulceration, this severely limits evaluation of patients. To allow such real-time subject-specific analysis, we developed a hierarchal modeling system which integrates a two-dimensional gross structural model of the foot (high-order model) with local finite element (FE) models of the plantar tissue padding the calcaneus and medial metatarsal heads (low-order models). The high-order whole-foot model provides real-time analytical evaluations of the time-dependent plantar fascia tensile forces during the stance phase. These force evaluations are transferred, together with foot-shoe local reaction forces, also measured in real time (under the calcaneus, medial metatarsals and hallux), to the low-order FE models of the plantar pad, where they serve as boundary conditions for analyses of local deformations and stresses in the plantar pad. After careful verification of our custom-made FE solver and of our foot model system with respect to previous literature and against experimental results from a synthetic foot phantom, we conducted human studies in which plantar tissue loading was evaluated in real time during treadmill gait in healthy individuals (N = 4). We concluded that internal deformations and stresses in the plantar pad during gait cannot be predicted from merely measuring the foot-shoe force reactions. Internal loading of the plantar pad is constituted by a complex interaction between the anatomical structure and mechanical behavior of the foot skeleton and soft tissues, the body characteristics, the gait pattern and footwear. Real-time FE monitoring of internal deformations and stresses in the plantar pad is therefore required to identify elevated deformation/stress exposures toward utilizing it in gait laboratories to protect feet that are susceptible to injury.

Adult↗

How to select the elastic modulus for cancellous bone in patient-specific continuum models of the spine.

Patient-specific finite element (FE) modelling is a promising technology that is expected to support clinical assessment of the spine in the near future. To allow rapid, robust and economic patient-specific modelling of the whole spine or of large spine segments, it is practicable to consider vertebral cancellous bone in the spine as a continuum material, but the elastic modulus of that continuum material must reflect the quality of the individual vertebral bone. A numerical parametric model of lattice trabecular architecture has been developed for determining the apparent elastic modulus of cancellous bone Ecb in vertebrae. The model inputs were apparent morphological parameters (trabecular thickness TbTh and trabecular separation TbSp) and the bone mineral density (BMD), which can all be measured in vivo, using the spatial resolution of current clinical quantitative computed tomography (QCT) commercial whole-body scanners. The model predicted that Ecb values between 30 and 110 MPa represent normal morphology and BMD of human spinal cancellous bone. The present Ecb to TbTh, TbSp and BMD relationships pave the way for automatic generation of patient-specific continuum FE spine models that consider the individual's osteoporotic or other degenerative condition of cancellous bone.

Bone Density↗

Contribution of muscular weakness to osteoporosis: computational and animal models.

BACKGROUND: Chronic weakness of the femoral musculature with old age may result in prolonged exposure of bone to critical understressing and, thus, cause osteoporotic changes. This study aims at quantifying long-term changes in thickness and mechanical properties of trabecular bone at the proximal femur due to muscular weakness. METHODS: We utilized computational models of typical planar trabecular lattices at the proximal femur for simulating long-term changes in morphological and mechanical properties of trabecular bone. Incorporating cellular communication network with osteocytes as mechanosensors, the models were able to mimic mechanotransduction and consequent thickening and/or thinning of individual trabeculae in response to altered gluteus muscle and hip joint loads. We also studied a rat model (n=14) in which we surgically detached the gluteus muscle, to approximately 50% or completely. FINDINGS: The computational simulations showed that when the force of the gluteus decreased (with or without simultaneous decrease in hip joint load), the most dramatic degradation in bone density, strength and stiffness occurred at the greater trochanter. Animal studies also demonstrated significant thinning of femoral trabeculae after 19 weeks of adaptation. Specifically, Tukey-Kramer analysis showed that rats subjected to partial surgical detachment of the gluteus had femoral trabeculae that were 22% thinner than controls (P<0.05). INTERPRETATION: The present study showed that in both the computer and animal models, manipulation of muscle loading produced a significant stimulus for bone to adapt, i.e., a stimulus that is beyond its irresponsive 'lazy zone'. Accordingly, the results obtained herein indicate that muscular weakness may be an important factor contributing to osteoporosis.

Adaptation, Physiological↗

Trabecular bone contributes to strength of the proximal femur under mediolateral impact in the avian.

BACKGROUND: Osteoporosis in long bones involves loss of cortical thickness and of the trabecular microarchitecture. Deterioration and weakening of trabecular bone tissue during osteoporosis imposes greater physiological loads on the cortical shell. However, it is unclear whether trabecular bone significantly contributes to the strength of whole bones under non-physiological impact loads. METHOD OF APPROACH: We hypothesize that trabecular tissue in epiphyses of long bones contributes to resisting and distributing impact loads. To test this hypothesis, we caused artificial trabecular bone loss in proximal femora of adult hens but did not alter the bone cortex. Subsequently, we compared the energy required to fracture the proximal part of femora with missing trabecular tissue with the energy required to fracture control femora, by means of a Charpy test. RESULTS: Extensive loss of trabecular bone in hens (over 0.50 grams or approximately 71% weight fraction) significantly reduced the energy required to fracture the whole proximal femur in mediolateral impacts (from approximately 0.37 joule in controls to approximately 0.20 joule after extraction of core trabecular tissue). CONCLUSIONS: These findings indicate that trabecular bone in the proximal femur is important for distributing impact loads applied to the cortex, and support the concept that in treating osteoporosis to prevent hip fractures, it is just as important to prevent trabecular bone loss as it is important to prevent loss of cortical thickness.

Animals↗

In vivo muscle stiffening under bone compression promotes deep pressure sores.

Pressure sores (PS) in deep muscles are potentially fatal and are considered one of the most costly complications in spinal cord injury patients. We hypothesize that continuous compression of the longissimus and gluteus muscles by the sacral and ischial bones during wheelchair sitting increases muscle stiffness around the bone-muscle interface over time, thereby causing muscles to bear intensified stresses in relentlessly widening regions, in a positive-feedback injury spiral. In this study, we measured long-term shear moduli of muscle tissue in vivo in rats after applying compression (35 KPa or 70 KPa for 1/4-2 h, N = 32), and evaluated tissue viability in matched groups (using phosphotungstic acid hematoxylin histology, N = 10). We found significant (1.8-fold to 3.3-fold, p < 0.05) stiffening of muscle tissue in vivo in muscles subjected to 35 KPa for 30 min or over, and in muscles subjected to 70 KPa for 15 min or over. By incorporating this effect into a finite element (FE) model of the buttocks of a wheelchair user we identified a mechanical stress wave which spreads from the bone-muscle interface outward through longissimus muscle tissue. After 4 h of FE simulated motionlessness, 50%-60% of the cross section of the longissimus was exposed to compressive stresses of 35 KPa or over (shown to induce cell death in rat muscle within 15 min). During these 4 h, the mean compressive stress across the transverse cross section of the longissimus increased by 30%-40%. The identification of the stiffening-stress-cell-death injury spiral developing during the initial 30 min of motionless sitting provides new mechanistic insight into deep PS formation and calls for reevaluation of the 1 h repositioning cycle recommended by the U.S. Department of Health.

Animals↗

Mechanical compression-induced pressure sores in rat hindlimb: muscle stiffness, histology, and computational models.

Pressure sores affecting muscles are severe injuries associated with ischemia, impaired metabolic activity, excessive tissue deformation, and insufficient lymph drainage caused by prolonged and intensive mechanical loads. We hypothesize that mechanical properties of muscle tissue change as a result of exposure to prolonged and intensive loads. Such changes may affect the distribution of stresses in soft tissues under bony prominences and potentially expose additional uninjured regions of muscle tissue to intensified stresses. In this study, we characterized changes in tangent elastic moduli and strain energy densities of rat gracilis muscles exposed to pressure in vivo (11.5, 35, or 70 kPa for 2, 4, or 6 h) and incorporated the abnormal properties that were measured in finite element models of the head, shoulders, pelvis, and heels of a recumbent patient. Using in vitro uniaxial tension testing, we found that tangent elastic moduli of muscles exposed to 35 and 70 kPa were 1.6-fold those of controls (P < 0.05, for strains </=5%) and strain energy densities were 1.4-fold those of controls (P < 0.05, for strains >/=5%). Histological (phosphotungstic acid hematoxylin) evaluation showed that this stiffening accompanied extensive necrotic damage. Incorporating these effects into the finite element models, we were able to show that the increased muscle stiffness in widening regions results in elevated tissue stresses that exacerbate the potential for tissue necrosis. Interfacial pressures could not predict deep muscle (e.g., longissimus or gluteus) stresses and injuring conditions. We conclude that information on internal muscle stresses is required to establish new criteria for pressure sore prevention.

Animals↗

Single-trabecula building block for large-scale finite element models of cancellous bone.

Recent development of high-resolution imaging of cancellous bone allows finite element (FE) analysis of bone tissue stresses and strains in individual trabeculae. However, specimen-specific stress/strain analyses can include effects of anatomical variations and local damage that can bias the interpretation of the results from individual specimens with respect to large populations. This study developed a standard (generic) 'building-block' of a trabecula for large-scale FE models. Being parametric and based on statistics of dimensions of ovine trabeculae, this building block can be scaled for trabecular thickness and length and be used in commercial or custom-made FE codes to construct generic, large-scale FE models of bone, using less computer power than that currently required to reproduce the accurate micro-architecture of trabecular bone. Orthogonal lattices constructed with this building block, after it was scaled to trabeculae of the human proximal femur, provided apparent elastic moduli of approximately 150 MPa, in good agreement with experimental data for the stiffness of cancellous bone from this site. Likewise, lattices with thinner, osteoporotic-like trabeculae could predict a reduction of approximately 30% in the apparent elastic modulus, as reported in experimental studies of osteoporotic femora. Based on these comparisons, it is concluded that the single-trabecula element developed in the present study is well-suited for representing cancellous bone in large-scale generic FE simulations.

Animals↗

[Diffusion of ulcers in the diabetic foot is promoted by stiffening of plantar muscular tissue under excessive bone compression].

The abnormally elevated plantar pressures under the bony prominences of the diabetic foot (mainly under the medial metatarsal heads and calcaneus) were associated with intensified internal stresses in the deep soft tissues padding these bones. In this study, we tested changes in mechanical properties of muscular tissue after exposure to the internal stress levels typically developing under the first and second metatarsal heads in the load bearing diabetic foot (40-80 KPa). The gracilis muscles of anesthetized rats were subjected to constant external pressures of 35 and 70 KPa for 2 h, which caused average internal compression stresses of 40 and 80 KPa, respectively, within the living gracilis. The animals were then killed and the tangent elastic moduli of the harvested gracilis were measured in uniaxial tension at strains of 2.5%, 5% and 7.5%. Tangent moduli of gracilis muscles exposed to internal compression of 40-80 KPa in vivo ( n=6) were 1.6-fold stiffer ( p<0.05) than those of controls ( n=6). These abnormally stiff mechanical properties were incorporated into a finite element (FE) model of the plantar tissue under the second ray of the foot, and were shown to increase the magnitude of deep internal stresses and project elevated stresses to larger regions. Hence, the integration of animal model data with FE simulations indicates a mechanism of plantar tissue deterioration in the diabetic foot, where muscles exposed to critical stresses respond with increased stiffness which then further intensifies the deep plantar stresses. This suggests a new positive feedback mechanism for the diffusion of ulcers and the atrophy of intrinsic plantar muscles in the diabetic foot, where the injury spreads from deep muscles to the skin surface by an evolving mechanical stress wave.

Animals↗

Comparison of the trabecular architecture and the isostatic stress flow in the human calcaneus.

It is a common theory that the architecture of trabecular bone follows the principal stress trajectories, as suggested by Wolff's pioneering studies of the proximal femur. Since first published in the late 19th-century, this observation (popularized as "Wolff's law") has been supported by numerous studies, but nearly all of them have been focused on the femoral head and neck. In this study, the manifestation of Wolff's law in the human calcaneus has been analyzed. For this purpose, finite element (FE) analysis of the entire complex of the foot during standing was undertaken. Orientation of the principal stress flow through the calcaneus was compared with the trabecular alignment in a single cadaveric calcaneal specimen, by fitting second-order polynomials to real trabecular paths and FE-predicted isostatics and calculating their angle of inclination with the calcaneal cortex at their insertion points. Four dominant trabecular patterns were identified in the cadaveric sagittal section of the specimen of the calcaneus: one directed primarily in the dorsal-plantar direction, one aligned anteriorly-posteriorly, and two that are strongly oblique. Subsequent numerical simulations showed that the dorsal-plantar oriented and posterior oblique trabecular paths are aimed to support compressive stresses, while the antero-posteriorly directed and anterior oblique groups act to bear tension. Insertion angles of real trabecular paths into the calcaneal cortex were similar to those of the isostatics that were computed under musculoskeletal loading conditions of standing (maximum absolute local difference 13 degrees, maximum local error 60%). This suggests that the trabecular patterns of the calcaneus are mainly shaped by isostatics (static principal stress flow) that are characteristic of the standing posture. The present modeling approach can be utilized to explore effects of abnormal alterations in the isostatic flow on the microarchitecture of the calcaneal trabeculae, as well as for better understanding of the mechanisms of calcaneal fractures.

Adult↗

Biomechanical analysis of fatigue-related foot injury mechanisms in athletes and recruits during intensive marching.

An integrative analysis, comprising radiographic imaging of the foot, plantar pressure measurements, surface electromyography (EMG) and finite element (FE) modelling of the three-dimensional (3D) foot structure, was used to determine the effects of muscular fatigue induced by intensive athletic or military marching on the structural stability of the foot and on its internal stress state during the stance phase. The medial/lateral (M/L) tendency towards instability of the foot structure during marching in fatigue conditions was experimentally characterised by measuring the M/L deviations of the foot-ground centre of pressure (COP) and correlating these data with fatigue of specific lower-limb muscles, as demonstrated by the EMG spectra. The results demonstrated accelerated fatigue of the peroneus longus muscle in marching conditions (treadmill march of 2 km completed by four subjects at an approximately constant velocity of 8 km h-1). Severe fatigue of the peroneus longus is apparently the dominant cause of lack of foot stability, which was manifested by abnormal lateral deviations of the COP during the stance phase. Under these conditions, ankle sprain injuries are likely to occur. The EMG analysis further revealed substantial fatigue of the pre-tibial and triceps surae muscles during intensive marching (averaged decreases of 36% and 40% in the median frequency of their EMG signal spectra, respectively). Incorporation of this information into the 3D FE model of the foot resulted in a substantial rise in the levels of calcaneal and metatarsal stress concentrations, by 50% and 36%, respectively. This may point to the mechanism by which stress fractures develop and provide the biomechanical tools for future clinical investigations.

Adolescent↗

Computational simulations of stress shielding and bone resorption around existing and computer-designed orthopaedic screws.

Failure of an orthopaedic fixation due to stress shielding and consequent screw loosening is a major concern among surgeons: the loosened screws could not only interfere with the healing process but also endanger adjacent anatomical structures. In this study, the effect of the screw's engineering design (dimensions, profile shape and material properties) on the load sharing with adjacent bone and consequent bone resorption was tested, using a set of two-dimensional computational (finite element) models. An algorithm simulating local bone adaptation to strain energy density (SED) mechanical stimuli was developed and used to evaluate the biomechanical performances of different commercial screws. Two new designs, a 'graded-stiffness' composite screw, with a reduced-stiffness titanium core and outer polymeric threads, and an active-compression hollow screw that generates compressive stresses on the surrounding bone, were also evaluated. A dimensionless set of stress transfer parameters (STPs) were utilised for ranking the performances of the different screws according to the expected screw-bone load sharing and its evolution with adaptation of the surrounding tissue. The results indicated that commercial wide (6 mm thread diameter) trapezoidal and rectangular screw profiles have superior biomechanical compatibility with bone (i.e. predicted to be stable after 2 years). The graded-stiffness and active-compression screws provided the best biomechanical performances: bone loading around them was predicted to decrease by no more than 15% after 3 years, compared with a decrease of 55-70% in bone loading around commercially available screws. Computer simulations of bone adaptation around orthopaedic screws are demonstrated to be effective means for objective and quantitative evaluation of the biomechanical aspects of implant-tissue compatibility.

Bone Resorption↗

Optimizing the biomechanical compatibility of orthopedic screws for bone fracture fixation.

Progressive loosening of bone fixation screws is a well-documented phenomenon, induced by stress shielding and subsequent adaptive bone remodeling which results in bone loss around the screw. A set of two-dimensional computational (finite element) models was developed in order to test the effect of various engineering designs of fixation screws on the predicted screw-bone stress transfer, and consequently, on the biomechanical conditions for osteosynthesis. A dimensionless set of stress-transfer parameters (STP) was developed to quantify the screw-bone load sharing, enabling a convenient rating to be given of the biomechanical compatibility of practically any given screw design according to the nature of the simulated mechanical interaction. The results indicated that newly proposed screw designs, i.e. a "graded-stiffness" composite screw with a reduced-stiffness-titanium core and outer polymeric threads and an "active-compression" hollow screw which generates compressive stresses on the surrounding bone, are expected to provide significantly better biomechanical performances in terms of the STP criteria, compared with conservative screw designs. Accordingly, the present work demonstrates that finite element computer simulations can be used as a powerful tool for design and evaluation of bone screws, including geometrical features, material characteristics and even coatings.

Biocompatible Materials↗

Design evaluation of commonly used rigid and levering laryngoscope blades.

BACKGROUND: The shape of a laryngoscope blade affects the exposition of the larynx. This study evaluates and compares some rigid and levering blade designs based on previous investigative X-ray laryngoscopic studies. METHODS: Five rigid laryngoscope blades (Miller #3, Standard Macintosh #3, Classical Macintosh #4 and English-Macintosh #3 and #4) and two levering laryngoscope blades (McCoy in neutral and maximally elevated positions and Flexiblade in three basic positions: straight, neutral, and maximally curved) were evaluated. This study assesses two parameters derived from the depth of insertion: the eye line deviation from the ideal straight view line to the vocal cords, and the space occupied by the blade behind the mandible, which affects the contact of the blade tip with the base of the tongue. RESULTS: The best results on larynx exposition were produced by the English-Macintosh #4 at all insertion depths between 5 and 14 cm. It surpassed the Classical Macintosh #4 and both the English and Standard Macintosh #3. Although the Miller and the Flexiblade in a straight position afford a nearly ideal view line, both blades reduce the space reserved for the tongue behind the mandible. The McCoy with its tip maximally elevated provides limited view, while activation of the Flexiblade provides various ranges of larynx exposition. CONCLUSION: The difference in shape and design of Macintosh blades affects their performance. The distal portion of a large-sized curved blade is more effective than the full length of a shorter blade. The #4 English Macintosh is a better choice for routine clinical use. The Flexiblade performs as a multiblade device and can therefore be used for both routine and difficult intubations.

Equipment Design↗

Biomechanical aspects of Peyronie's disease in development stages and following reconstructive surgeries.

Peyronie's disease is a disorder of the penile connective tissues that leads to development of dense fibrous or ossified plaques in the tunica albuginea, causing penile deformity and painful erection. A biomechanical model of the penis was utilized for analyzing the mechanical stresses that develop within its soft tissues during erection in the presence of Peyronie's plaques. The model's simulations demonstrated stress concentrations around nerve roots and blood vessels due to the plaques. These stresses may irritate nerve endings or compress the vascular bed, and thus cause penile deformity and/or painful erection. The model was further used to elaborate the effects of different biological or artificial materials for reconstruction of the penis following plaque removal. Clinical applications of the present model can range from analysis of the etiology of the disease to assisting in the determination of optimal timing for therapeutic interventions and in the selection of patch material for penile reconstructions.

Biomechanical Phenomena↗

In vivo biomechanical behavior of the human heel pad during the stance phase of gait.

A technique is introduced for simultaneous measurements of the heel pad tissue deformation and the heel-ground contact stresses developing during the stance phase of gait. Subjects walked upon a gait platform integrating the contact pressure display optical method for plantar pressure measurements and a digital radiographic fluoroscopy system for skeletal and soft tissue motion recording. Clear images of the posterior-plantar aspect of the calcaneus and enveloping soft tissues were obtained simultaneously with the pressure distribution under the heel region throughout the stance phase of gait. The heel pad was shown to undergo a rapid compression during initial contact and heel strike, reaching a strain of 0.39 +/- 0.05 in about 150 ms. The stress-strain relation of the heel pad was shown to be highly non-linear, with a compression modulus of 105 +/- 11 kPa initially and 306 +/- 16 kPa at 30% strain. The energy dissipation during heel strike was evaluated to be 17.8+/-0.8%. The present technique is useful for biomechanical as well as clinical evaluation of the stress-strain and energy absorption characteristics of the heel pad in vivo, during natural gait.

Adult↗

Integration of plantar soft tissue stiffness measurements in routine MRI of the diabetic foot.

OBJECTIVE: A method of measuring mechanical properties of plantar soft tissues in vivo by integrating a photoelastic technique into an MRI system is presented. BACKGROUND: Plantar tissue stiffening in the diabetic foot is associated with development of ulcers at the highest-pressure sites. MRI is used as an effective means of demonstrating tissue damage caused by diabetic ulceration. DESIGN: The new measurement method uses the indentation of a sphere into the plantar tissue, which is simultaneously scanned by MRI. The indentation force is obtained using the photoelastic technique while tissue deflection is measured on the MRI scans, to yield a characteristic load-displacement curve. METHODS: Applicability of the proposed method in characterizing the plantar tissue stiffness and indentation patterns of two young normal subjects and two older diabetic patients was tested. RESULTS: Significantly higher effective shear and elastic moduli were measured for the diabetic plantar tissue compared with that of normal. For the diabetic patients, local stiffness in proximity of the 1st metatarsal head was substantially larger than in other sites, and this could be associated with initial tissue ulceration at this location. RELEVANCE: The present method seems applicable as a practical means of identifying regions in the diabetic plantar tissue that are vulnerable to ulceration, and can be easily integrated into routine MRI scans for assessing tissue damage in these patients.

Case-Control Studies↗