PubMed Health⌕ Search

Biomedical subjects

A Geisel

Publications and source records attributed to A Geisel.

11 recordsLinked to original sources

Automated system for infrared spectrometric analysis for total CO2 of plasma contained in capillary tubes.

We describe how to assay plasma total CO2 automatically, discretely, and highly specifically by infrared absorption spectrometry. Plasma, 50 mul, is sampled in disposable capillaries and inserted into a block wherein the specimens are protected from exposure to air. A sequencer advances the block and signals a dispenser to flush the sample into a reaction vessel with 2.6 ml fo 50 mmol/liter H2SO4. After 24 s of incubation, the evolved CO2 is swept into a 1-meter infrared gas cell by a stream of nitrogen. A recorder displays the resulting peak in absorbance units. Operation of all valves controlling gas and liquid flow is regulated by the sequencer. In the present version, the time required for analysis of one sample is 65 s. The sample size may be reduced by at least 10-fold and the time sequence accelerated to assay 70-80 specimens per hour.

Autoanalysis↗

The influence of carbenoxolone on steroid-induced ulcer and mucus secretion in the rat.

In rats, gastric mucus was decreased by starvation. The administration of carbenoxolone sodium, prednisolone, or their combination to starved rats brought the level of gastric mucus to that of nonstarved controls. Concomitant treatment with carbenoxolone sodium did not prevent prednisolone-induced ulceration of the glandular stomach in starved rats. The ulcerations of the prostomach (squamous spithelium)induced by starvation were prevented by carbenoxolone sodium, prednisolone, or the combination of the two.

Animals↗

A new factor in the blood of patients with peptic ulcer. Distribution in blood fractions.

Previous work on a factor in the blood of patients with peptic ulcer which contracts smooth muscle was confirmed and the work extended to investigation of the activity of blood fractions. Whole heparinized blood and its fractions were tested on a strip of guinea pig ileum and height of contraction and latent period were used as criteria of activity. Whole heparinized blood of ulcer patients had significantly higher activity than that of normal controls. Differences between the fractions of ulcer patients and controls were less significant. With the lysed buffy coat, however, while the differences between the height of contraction between the groups did not differ statistically, the speed of the reaction (shorter latent period) was significantly greater in the ulcer patients. The cellular alterations causing this response are unknown.

Animals↗