PubMed Health⌕ Search

Biomedical subjects

A Gh Podoleanu

Publications and source records attributed to A Gh Podoleanu.

2 recordsLinked to original sources

Optical coherence tomography.

A review is presented of different scanning, acquisition and processing techniques used to obtain depth-resolved information in optical-coherence tomography (OCT). The principles and performances of different OCT techniques are discussed and images from different types of tissue are presented. Special attention is devoted to the progress in using the time-domain flying spot OCT technique and combination of the en face OCT imaging with confocal microscopy. Although OCT is based on white light interferometry, which is a well established and an old technology, the quest for higher resolution and faster acquisition of in vivo images has ensured OCT a rapid evolution in the last decade. Highly adventurous avenues to expand the OCT capabilities and trends are presented at the end of the review.

Contrast Media↗

3-D optical coherence tomography of the laryngeal mucosa.

Laryngeal carcinoma is one of the commonest primary head and neck malignancy and the need for early identification is very important for successful treatment. Outpatient fibreoptic examination of the larynx is unreliable in differentiating benign, pre-malignant and malignant lesions, and therefore surgeons have to rely on biopsies for a definitive diagnosis. This is an invasive procedure requiring general anaesthesia and may have a detrimental effect on the patient's voice. Conventional imaging modalities (ultrasound, computed tomography and magnetic resonance imaging) have a limited resolution and hence cannot give sufficient information on the extent or nature of laryngeal lesions. The aim of our study is to investigate the feasibility of optical coherence tomography (OCT) in imaging the normal larynx, to lay the foundations for an investigation of its ability to differentiate between benign and malignant disease. Ten tissue specimens from normal larynges were imaged with an 850 nm OCT system that was capable of providing both B-scan (longitudinal or cross-section) images as well as C-scan (en-face or images at constant depth). The en-face OCT mode allowed us to reconstruct 3-D OCT images of the tissue examined. Imaged specimens were processed with standard histopathological techniques and sectioned in the plane of the B-scan OCT images. Haematoxylin-eosin stained specimens were compared with the OCT images thus collected. Preliminary results showed good correlation between OCT images and histology sections in normal tissue.

Humans↗