PubMed Health⌕ Search

Biomedical subjects

A Ghuran

Publications and source records attributed to A Ghuran.

7 recordsLinked to original sources

Circadian behavior of P-wave duration, P-wave area, and PR interval in healthy subjects.

BACKGROUND: The prolongation of P-wave duration has long been shown to indicate the presence of high risk for atrial fibrillation. The circadian variation of P-wave characteristics and their dynamic adaptation to heart rate changes was not tested before. METHODS: To evaluate the diurnal pattern of P-wave duration, P area, and PR interval and of their linearly fitted relation with RR interval, 50 healthy volunteers (25 men, mean age 34 +/- 10 years) underwent 24-hour ambulatory electrocardiographic (ECG) recording with digital 12-lead Holter recorders. The median P-wave duration, P area, and PR interval were calculated from the average 12-lead ECG constructed from each 10-second ECG recording. Single harmonic regression analysis was performed to reveal the presence of circadian variation in the aforementioned ECG parameters. RESULTS: The P area (P < 0.0001, R(2) = 0.78), the PR interval (P < 0.0001, R(2) = 0.92), the P area / RR slope (P < 0.0001, R(2) = 0.55), and the PR/RR slope (P < 0.0001, R(2) = 0.42) showed a highly significant circadian variation while the periodic nature of P-wave duration (P = 0.016, R(2) = 0.32) and of the P duration / RR slope (P = 0.011, R(2) = 0.18) was only indicated by harmonic regression analysis. CONCLUSIONS: P-wave duration, P area, and PR interval show a significant circadian variation in healthy subjects. The relations between P area/RR,PR/ RR, and P duration/RR also demonstrate a significant diurnal pattern.

Adult↗

New descriptors of homogeneity of the propagation of ventricular repolarization.

Available descriptors of irregularities of ventricular repolarization are of limited clinical value. We studied the effect of autonomic variations on several new descriptors of the three-dimensional T loop. Twelve-lead digital ECGs were recorded continuously in 40 healthy subjects at baseline in the supine position, during postural changes (supine-->sitting-->standing-->supine-->standing), and during Valsalva maneuver performed three times in the supine and three times in the standing positions. A minimum dimensional space was constructed from the 12-lead ECG, using singular value decomposition, on the basis of median ECG beats constructed from 10-second consecutive ECG recordings. Temporal variations (TLA and PL, which measure the T loop area, and LD, the interlead relationship during repolarization) and wavefront direction descriptors (TCRT, the deviation between the QRS and T vectors) were calculated and expressed as normalized values. Values of TLA, PL, and TCRT were significantly lower in the sitting than in the supine position (-38,139 +/- 9099 vs 47,133 +/- 7511, -0.017 +/- 0.005 vs 0.033 +/- 0.005 and -0.032 +/- 0.019 vs 0.071 +/- 0.015, respectively, P < 0.001 for all) and decreased further in the standing position (-88,288 +/- 14,468, -0.067 +/- 0.013, -0.198 +/- 0.025, respectively, P < 0.001 for all). LD increased from supine to sitting (98.7 +/- 29.4 vs -87.5 +/- 15.2, P < 0.001) and increased further, though nonsignificantly in the standing position (118.3 +/- 35.2). TLA, PL, and TCRT decreased from baseline during Valsalva in the supine (-34,118 +/- 11,424 vs 62,234 +/- 12,215, -0.038 +/- 0.014 vs 0.065 +/- 0.010, -0.08 +/- 0.03 vs 0.10 +/- 0.02, respectively, P < 0.001 for all) and standing positions (-108,263 +/- 21,051 vs -68,909 +/- 10,271, -0.109 +/- 0.014 vs -0.048 +/- 0.009, -0.30 +/- 0.035 vs -015 +/- 0.016, respectively, P < 0.05 for all). LD was significantly increased by Valsalva in the supine position (13 +/- 46 vs -153 +/- 30, P < 0.001) and nonsignificantly in the standing position (99 +/- 50 vs 86 +/- 30, P = NS). There were significant correlations among TLA, PL, and LD, and no significant correlation between TCRT and any of the temporal variation descriptors. These new temporal and wavefront direction descriptors are sensitive and rapid detectors of autonomic effects on ventricular repolarization.

Adolescent↗

Reflex autonomic modulation of automatically measured repolarization parameters.

Automatic recognition of repolarization abnormalities from the standard electrocardiogram (ECG) is of considerable clinical importance. This study examined the autonomic variations in automatically measured repolarization parameters, including maximum QT interval (QTmax), global QT dispersion (QTd), T area dispersion (T area D) and principal component analysis ratio 2 (PCA-2). Twelve-lead ECGs were recorded continuously in 40 healthy subjects during supine, sitting and standing positions, and during the Valsalva maneuver. With the exception of PCA-2, the other repolarization parameters correlated either moderately or strongly during the steady-state supine position. QTmax, PCA-2, and T area D decreased significantly between supine and sitting position (P < 0.001, P < 0.001 and P < 0.01, respectively). QTmax, QTD, and T area D decreased significantly between sitting and standing (P < 0.001, P < 0.05 and P < 0.01, respectively). All parameters significantly decreased between supine and standing position: QTmax (P < 0.001), QTD (P < 0.05), PCA-2 (P < 0.05) and T area D (P < 0.001). During Valsalva, only PCA-2 increased significantly (P < 0.001) between supine and standing position. There were no significant changes in QT dispersion and dispersion of T wave area during Valsalva, compared to baseline, in both supine and standing positions. Automatic conventional measures of repolarization heterogeneity have limited practical value in detecting the effects of autonomic changes on ventricular repolarization. Newer concepts evaluating spatial and temporal irregularity of ventricular repolarization are still needed to reliably detect the effects of autonomic activity on ventricular repolarization.

Adolescent↗