Regaining chondrocyte phenotype in thermosensitive gel culture.

Chondrocyte tissue engineering continues to be a challenging problem. When chondrocytes are duplicated in vitro, it is imperative to obtain an adequate number of cells of optimal phenotype. A temperature-sensitive polymer gel, a copolymer of poly(N-isopropylacrylamide) and acrylic acid (PNiPAAm-co-Aac), has the ability of gelling at 37 degrees C (the lower critical solution temperature, LCST) or above and liquefying below that temperature (Vernon and Gutowska, Macromol. Symp. 1996;109:155-167). The hypothesis of this study was that chondrocytes could (1) duplicate in the copolymer gel; (2) regain their chondrocyte phenotype; and (3) be easily recovered from the gel by simply lowering the temperature below 37 degrees C. Chondrocytes from adult rabbit scapular cartilage were harvested and cultured in a monolayer culture until confluency (approximately 2 weeks). Next, the cells were harvested and seeded into the copolymer gel and cultured for 2-4 weeks. The phenotype of the cultured cells was then characterized. Two groups of control cultures, monolayer and agarose gel, were used to compare their ability to maintain chondrocyte phenotype. The results showed that chondrocytes isolated from rabbit scapula can re-express chondrocyte phenotype in agarose culture and polymer gel culture but not in monolayer culture. Also, cultured chondrocytes can be easily recovered from polymer gel culture by simply lowering the temperature. This new in vitro method of chondrocyte culture is recommended for chondrocyte propagation and regaining chondrocyte phenotype before cell seeding or transplantation.

Acrylamide↗

Injectable gels for tissue engineering.

Recently, tissue engineering approaches using injectable, in situ gel forming systems have been reported. In this review, the gelation processes and several injectable systems that exhibit in situ gel formation at physiological conditions are discussed. Applications of selected injectable systems (alginate, chitosan, hyaluronan, polyethylene oxide/polypropylene oxide) in tissue engineering are also described. Injectable polymer formulation can gel in vivo in response to temperature change (thermal gelation), pH change, ionic cross-linking, or solvent exchange. Kinetics of gelation is directly affected by its mechanism. Injectable formulations offer specific advantages over preformed scaffolds such as: possibility of a minimally invasive implantation, an ability to fill a desired shape, and easy incorporation of various therapeutic agents. Several factors need to be considered before an injectable gel can be selected as a candidate for tissue engineering applications. Apart from tissue-specific cell-matrix interactions, the following gel properties need to be considered: gelation kinetics, matrix resorption rate, possible toxicity of degradation products and their elimination routes, and finally possible interference of the gel matrix with histogenesis.

Alginates↗

Bioabsorption qualities of chitosan-absorbable vascular templates(1).

PURPOSE:The scope of endovascular surgical techniques has expanded to include the treatment of diseases considered at one time to be amenable only to surgical treatment. The development of the biodegradable template follows as an extension of current permanent stent technology. The goal of our project is to develop and test chitosan as an absorbable template for the vascular system.Ultrapure chitosan, heparin sodium salt and lysozyme, and contrast agents MD-76R and Oxilan-350 were used to give radioopaque quality. Prototype chitosan vascular templates were obtained by a dip coating method in which alternate layers of chitosan were coagulated with nonsolvents or heparin. The amount of loaded and released heparin was determined using Azure II colorimetric assay. In vitro enzymatic degradation of templates was evaluated using lysozyme solutions in phosphate buffered saline. Mechanical properties were analyzed using the Dynamic Mechanical Analyzer, DMA-7 (Perkin Elmer, Foster City, Calif.). The microstructure of freeze-dried templates was investigated by field emission scanning electron microscopy (FE SEM) using an LEO 982 electron microscope (Zeiss, Thornwood, NY).In vivo deployment of the templates was undertaken in 10 full-sized pigs (Sus scrofa). After open expose and control of the iliac artery, a closed balloon catheter technique was used to advance and place the balloon catheter and template. The balloon was then expanded, deploying a Palmaz stent with a chitosan template anchored distally. Patency and deployment of the stent-template complex was confirmed by an arteriogram. The animals were sacrificed at 1, 2, 3, 4, and 5 weeks poststent placement, and arterial sections were taken for microscopic analysis. The amount of chitosan remaining was estimated to determine an in vivo rate of absorption.On hematoxilyn and eosin staining of the section arterial samples, a marked inflammatory response was noted and progressed with duration of in vivo contact. A giant cell foreign body reaction coupled with intense intimal hyperplasia and organized thrombus was also noted and progressed with duration of time in vivo. Also noted was the degradation of the template material with only small remnants of material noted within the giant cell by week 4. Clinically, none of the pigs developed limb ischemia or evidence of thromboembolic events.In this in vivo study, the chitosan template proved to be biodegradable but elicited an intense thrombotic and foreign body reaction despite heparin bonding. Further investigation is ongoing as to decreasing the thrombogenic and antigenic qualities of the template materials by either alteration of the base material or addition of bioactive side chains.

Journal Article↗

Polymer molecular weight alters properties of pH-/temperature-sensitive polymeric beads.

PURPOSE: To study the physical and release properties of different molecular weight (MW) pH- and temperature-responsive statistical terpolymers and beads of N-isopropylacrylamide (NIPAAm), butylmethacrylate (BMA) and acrylic acid (AA). METHODS: Random terpolymers of varying MW were synthesized with NIPAAm/BMA/AA of feed mol ratio 85/5/10. Polymeric beads were formed by dropping a polymer solution into an oil bath kept at a temperature above the lower critical solution temperature (LCST) of the polymer. The release profile of cytochrome c was investigated as a function of the polymer MW and pH of the release medium at 37 degrees C. RESULTS: The weight average MW ranged between 49,000 and 3 million. The LCST at pH 2.0 and pH 7.4 was 22 degrees C and 60 degrees C respectively. SEM studies showed that the size of the pores decreased as the MW increased. Irrespective of MW, the polymeric beads did not swell or dissolve at pH 2.0 and 37 degrees C and showed minimal drug release. At pH 7.4 and 37 degrees C, the rate of bead dissolution/swelling decreased as the MW of the polymer increased. CONCLUSIONS: By modulating polymer MW, it was possible to vary the physical properties of beads. Dissolution/swelling characteristics were dependent on the MW of the polymer. Such unique dissolution/swelling properties are useful for delivering drugs to different sites in the intestine.

Acrylates↗

Heparin release from thermosensitive polymer coatings: in vivo studies.

Biomer/poly(N-isopropylacrylamide)/[poly(NiPAAm)] thermosensitive polymer blends were prepared and their application as heparin-releasing polymer coatings for the prevention of surface-induced thrombosis was examined. The advantage of using poly (NiPAAm)-based coatings as heparin-releasing polymers is based on the unique temperature-dependent swelling of these materials. At room temperature, i.e., below the lower critical solution temperature (LCST) of poly (NiPAAm), the Biomer/(poly(NiPAAm) coatings are highly swollen. The high swelling enables fast loading of hydrophilic macromolecules (e.g., heparin) into the coating by a solution sorption technique. At a body temperature, i.e., above the LCST of poly (NiPAAm) the coatings are in a deswollen state and the absorbed macromolecules may be slowly released from a dense coating via a diffusion controlled mechanism. Biomer/poly(NiPAAm) coatings were obtained by blending and coprecipitation of the two linear polymers, Biomer and (poly(NiPAAm). The structure and water-swelling properties of the coatings were examined. Significant differences in water swelling at room temperature (RT) and 37 degrees C were observed as a result of the thermosensitivity of poly (NiPAAm). The surface structure of the coatings in dry and swollen states at RT and 37 degrees C was examined by scanning electron microscopy. Heparin was loaded into the coatings via a solution sorption at room temperature. Kinetic studies of heparin loading demonstrated that maximum loading was obtained within 1 h. The in vitro (37 degrees C) release profiles were characterized by a rapid initial release due to the squeezing effect of the collapsing polymer network, followed by a slower release phase controlled by heparin diffusion through the dense coating. The short-term antithrombogenicity of intravenous polyurethane catheters coated with heparin-releasing Biomer/poly(NiPAAm) thermosensitive coating was evaluated in a canine animal model. The results show that the heparin release from Biomer/poly(NiPAAm)-coated surfaces resulted in a significant reduction of thrombus formation on test surfaces in contact with venous blood as compared to control surfaces.