PubMed Health⌕ Search

Biomedical subjects

A H Dachman

Publications and source records attributed to A H Dachman.

At least 19 recordsLinked to original sources

Tumor size on computed tomography scans: is one measurement enough?

BACKGROUND: Bidimensional tumor measurements are used routinely as surrogates for tumor volume. The purpose this study was to determine whether there is any added benefit in bidimensional or tridimensional measurements over a unidimensional measurement. METHODS: Sixty-nine colorectal hepatic metastases on 19 computed tomography scans (1-8 lesions per scan) from 9 patients were analyzed. Five patients contributed 2-4 scans each (mean, 3 scans). The standard volume of these lesions was determined by the "summation of areas" technique. The maximum axial dimension, the product of the greatest axial dimensions, and several volume estimates (based on the volumes of a sphere, an ellipsoid, and a cube) each were correlated with the standard volume. RESULTS: The maximum axial dimension and the product of the greatest axial dimensions correlated equally with tumor volume (correlation coefficient = 0.93). Surrogate measures based on the equations for a sphere and an ellipsoid underestimated tumor volume, whereas the equation for a cube overestimated volume. CONCLUSIONS: When reporting tumor size, there is no significant added benefit in reporting bidimensional or tridimensional measurements over the maximum axial dimension.

Data Interpretation, Statistical↗

Virtual colonoscopy: a novel imaging modality for colorectal cancer.

Advances in computed tomography (CT) technology and computer capabilities have contributed to the development of a new imaging modality for colorectal lesions called CT colonography or virtual colonoscopy. Virtual colonoscopy is a rapid, minimally invasive scan of the cleansed and distended colon. Early work has demonstrated that this test is safe and well tolerated, and that it may be sensitive and specific enough to identify most significant precancerous or cancerous lesions. A number of technical and practical problems remain before virtual colonoscopy can be applied at a population level.

Colonoscopy↗

Portal and mesenteric venous calcification in patients with advanced cirrhosis.

OBJECTIVE: The incidence of calcification in the portal and mesenteric venous system was studied in patients with advanced cirrhosis undergoing evaluation for liver transplantation. The significance of portal and mesenteric calcification on liver transplantation was also investigated. CONCLUSION: An 11% incidence of portal and mesenteric venous calcification was found in patients with cirrhosis, which was much higher than anticipated. Two (29%) of seven patients who had calcification present on CT and underwent liver transplantation died at surgery as a result of portal venous thrombosis. Thus, venous calcification seen on CT is a significant finding in patients undergoing liver transplantation.

Adult↗

Role of chest CT in the follow-up of ovarian adenocarcinoma.

OBJECTIVE: We describe the prevalence of metastatic chest disease in ovarian adenocarcinoma as seen on CT. We sought to determine whether routine chest CT added any pertinent information to the follow-up examination of patients with ovarian adenocarcinoma. MATERIALS AND METHODS: Retrospective review of our tumor registry yielded 96 patients with ovarian adenocarcinoma who had only a single primary malignancy and at least one CT scan of the chest, abdomen, and pelvis. CT scans were reviewed to assess the presence of metastatic chest disease in relation to disease activity in the abdomen and pelvis. Chest CT findings were correlated with the physical examination findings and CA-125 levels and were reviewed in consultation with a gynecologic oncologist to select only those patients with chest abnormalities attributable to metastatic disease. RESULTS: A total of 266 CT scans were obtained. Forty (41.7%) of the 96 patients had abnormalities attributable to metastatic chest disease on one or more scans. In the absence of disease progression in the abdomen and pelvis, chest disease progression was seen in only six (2.7%) of the 226 follow-up CT scans. Five of the six patients had rising CA-125 levels. CONCLUSION: Correlation of the findings of abdominal and pelvic CT with the physical findings and the CA-125 levels serves as effective follow-up in patients with ovarian adenocarcinoma. The contribution of additional chest CT in these patients is small.

Adenocarcinoma↗

Safety and efficacy of mangafodipir trisodium (MnDPDP) injection for hepatic MRI in adults: results of the U.S. multicenter phase III clinical trials (safety).

The short-term safety of mangafodipir trisodium (MnDPDP) injection was studied in 546 adults with known or suspected focal liver lesions. An initial contrast-enhanced computed tomography examination was followed by unenhanced magnetic resonance imaging (MRI), injection of MnDPDP (5 micromol/kg), and enhanced MRI. Adverse events were reported for 23% of the patients; most were mild to moderate in intensity, did not require treatment, and were not drug related. The most commonly reported adverse events were nausea (7%) and headache (4%). The incidence of serious adverse events was low (nine events in six patients) and not drug related. Injection-associated discomfort was reported for 69% of the patients, and the most commonly reported discomforts included heat (49%) and flushing (33%). Changes in laboratory values and vital signs were generally transient, were not clinically significant, and did not require treatment. There were no clinically significant short-term risks from exposure to MnDPDP.

Abdominal Pain↗

Efficacy and safety of mangafodipir trisodium (MnDPDP) injection for hepatic MRI in adults: results of the U.S. Multicenter phase III clinical trials. Efficacy of early imaging.

The efficacy of contrast-enhanced magnetic resonance imaging (MRI) for detecting and characterizing, or excluding, hepatic masses was assessed in 404 patients, following the intravenous administration of mangafodipir trisodium (MnDPDP) injection, a hepatic MRI contrast agent. An initial contrast-enhanced computed tomography (CT) examination was followed by unenhanced MRI, injection of MnDPDP (5 micromol/kg IV), and enhanced MRI at 15 minutes post injection. Agreement of the radiologic diagnoses with the patients' final diagnoses was higher for enhanced MRI and for the combined unenhanced and enhanced MRI evaluations than for unenhanced MRI alone or enhanced CT using the clinical diagnosis as the gold standard. Mangafodipir-enhanced MRI uniquely provided additional diagnostic information in 48% of the patients, and patient management was consequently altered in 6% of the patients. MnDPDP-enhanced MRI was comparable or superior to unenhanced MRI and enhanced CT for the detection, classification, and diagnosis of focal liver lesions in patients with known or suspected focal liver disease.

Adult↗

CT colonography: the next colon screening examination?

Computed tomographic (CT) colonography is a new-generation technique for detecting colorectal neoplasms by using volumetric CT data combined with specialized imaging software. Patient examinations require full colonic preparation, insufflation, and data acquisition with the patient in the supine and prone positions. Current CT technology allows a single image of the colon to be acquired in as little as 20 seconds with a minimum of patient discomfort. Specialized computer software for interpretation usually combines transverse, multiplanar reformation, and three-dimensional endoluminal images for the optimal visualization of the colon and rectum. As of the time this article was written, CT colonography was competitive as a full structural colonic examination for the detection of polyps and cancer. To the authors' knowledge, no study results have yet been reported in a screening population. The unique capabilities of CT colonography include the display of the proximal colon that is inaccessible at colonoscopy because of obstructing colonic lesions or because of incomplete endoscopic examinations and the assessment of extracolonic abdominal and pelvic organs. This abdominopelvic survey potential provides radiologists with an opportunity to discover other potentially life-threatening, asymptomatic conditions. Further technologic developments and validation studies are in progress. CT colonography is an exciting and promising technique with an enormous potential for colorectal screening in the future.

Colon↗

Automated calculation of the centerline of the human colon on CT images.

RATIONALE AND OBJECTIVES: This article presents an evaluation of an automated technique for determining the colon centerline with computed tomographic (CT) data sets. MATERIALS AND METHODS: The technique proceeds as follows. After indication of a voxel in the rectum, voxels corresponding to air were segmented. Points along the colon centerline were estimated on the basis of centers of mass of grown voxels. A second segmentation and centerline calculation was initiated at the cecum. These two centerlines were then averaged. The resulting average was refined by using lumen data obtained perpendicular to the average centerline. The accuracy of the technique was investigated with simulation phantoms. The technique was also evaluated for 40 clinical colon cases. Calculated centerline points were compared with those indicated by radiologists for a randomly selected clinical case. RESULTS: In the simulation studies, the calculated centerline points were, on average, within 2.5 mm of the true centerlines but differed by up to 4 mm in regions of deep folds or sharp turns. In the clinical colon study, 40% of the centerlines were computed with a single seed point and 25% with two seed points. Average centerlines were computed in 1 minute. The root mean square difference between the computed centerline points and those indicated by the radiologists was 4-5 mm (comparable to interobserver variations). CONCLUSION: Accurate centerlines can be determined from colon CT data with this automated technique.

Colon↗

CT findings after laparoscopic repair of ventral hernia.

OBJECTIVE: We describe CT findings after laparoscopic repair of ventral hernia with emphasis on formation of postoperative fluid collections that can mimic recurrent bowel herniation or infected postoperative fluid collections. CONCLUSION: The porous property of the mesh used in laparoscopic repair of ventral hernia allows reaccumulation of fluid in the existing hernia sac or spaces in the subcutaneous tissues that can be created by laparoscopic manipulation. These fluid collections should be expected and are differentiated from infected fluid collections or hernia recurrence by clinical presentation, laboratory data, and lack of ancillary features associated with true hernia such as presence of hernia sac, herniated mesentery, or bowel obstruction.

Body Fluids↗

Primary non-Hodgkin's splenic lymphoma.

OBJECTIVES: To describe the imaging, clinical and pathological features of primary splenic lymphoma using a strict definition. METHODS: Of 21 cases, plain films were available in nine, sonograms in 10 and CT in 16. We categorized the spleen as either normal, enlarged with no focal defects (type 1), studded with miliary masses (type 2), containing multifocal masses of varying size (1-10 cm) (type 3) or containing a solitary large mass >5 cm without (type 4A) or with (type 4B) central hypodensity/anechoic areas. RESULTS: Clinical presentations were left upper quadrant pain, weight loss and/or fever. One case was found incidentally on CT. Fourteen were type 4A, three type 4B, four type 3 and none were type 1 or 2. Nine of 10 cases were hypoechoic. In 11/12 cases with enhanced scans, the lesions are hypodense relative to the splenic parenchyma, and in one case, the lesion was necrotic. Rim enhancement was seen in one case. CONCLUSION: Primary splenic lymphoma usually presents as a mass or masses rather than with splenomegaly alone. Splenectomy may be required for diagnosis.

Adolescent↗

CT imaging in adults with neurofibromatosis-1: frequent asymptomatic plexiform lesions.

OBJECTIVE: The authors examined the incidence and radiologic characteristics of plexiform neurofibromas in neurofibromatosis-1 (NF-1) to define a cohort at greatest risk for malignant nerve-sheath tumors. BACKGROUND: Plexiform neurofibromas are a frequent complication of NF-1. They can impair function, produce disfigurement, and be the site for the development of malignant nerve-sheath tumors. The incidence and natural history of plexiform neurofibromas is unknown. METHODS: CT imaging of the chest, abdomen, and pelvis was performed in 91 of 125 consecutive adults (age, > or = 16 years) with NF-1. RESULTS: Twenty percent of patients had plexiform neurofibromas of the chest in the paraspinal, mediastinal, or supraclavicular area. Approximately 40% of patients had abnormal abdominal/pelvic scans. The paraspinal, sacral plexus, sciatic notch, and perirectal regions were the most common sites. Most plexiform neurofibromas were asymptomatic. Imaging also revealed a number of tumors, including malignant nerve-sheath tumors, adrenal tumors, carcinoids, and schwannomas. CONCLUSIONS: The frequency of plexiform lesions and other tumors in NF-1 indicates that clinicians should monitor young adults carefully; however, imaging characteristics alone cannot reliably distinguish benign from malignant lesions.

Abdominal Neoplasms↗

Imaging of pancreatic transplantation using portal venous and enteric exocrine drainage.

OBJECTIVE: We describe the normal radiologic appearance of pancreatic allografts transplanted using portal venous drainage with enteric drainage of exocrine secretions. We also describe the radiologic appearance of postsurgical complications. MATERIALS AND METHODS: Of 56 patients who received pancreatic transplants using the portal-enteric technique, 24 patients subsequently required radiologic examination for suspected complications involving the pancreatic allograft. Twenty-three patients underwent CT scanning; a total of 58 CT scans were obtained. Nine abdominal sonograms were obtained in five patients, and one patient underwent angiography. The radiologic appearance of each transplant and the complications were analyzed retrospectively and correlated with the clinical course. RESULTS: The most common indications for CT scanning were fever, elevated levels of serum amylase, and evaluation or follow-up of fluid collections. CT showed the normal and abnormal anatomy of the allograft. Abnormal findings seen in the 58 CT scans included fat stranding (30 scans), ascites (21 scans), peripancreatic fluid or pseudocyst (13 scans), and heterogeneity of the allograft (five scans). One patient had pancreatic infarction with pneumatosis and pneumoperitoneum. The allograft was obscured by bowel gas on three sonograms. Four sonograms showed no abnormalities (one Doppler sonogram showed the arterial supply and venous drainage), and one sonogram showed a pseudocyst. In the one patient who underwent angiography, imaging showed no arterial blood flow to the transplant. CONCLUSION: Pancreatic transplantation with portal venous drainage and enteric drainage of exocrine secretions and the complications of such transplantation were revealed with CT, sonography, and angiography. Knowledge of normal anatomic configuration will allow proper interpretation of normal and abnormal findings.

Adult↗

Helical CT examination of potential kidney donors.

OBJECTIVE: The purpose of our study was to evaluate helical CT using axial, coronal, and three-dimensional (3D) reconstruction in the examination of potential kidney donors and to compare the results with angiography and surgery when possible. We also reviewed previously published reports. SUBJECTS AND METHODS: Thirty-six patients underwent unenhanced and enhanced helical CT (3-mm collimation, 150-170 ml of i.v. contrast material injected at 4 ml/sec; pitch 1.5; 17-sec scan delay) with coronal and 3D shaded-surface-display reconstructions made from 1.5-mm overlapping reconstructions. All CT scans were interpreted independently of each other by two observers unaware of other findings. A third observer, who was aware of other findings, also interpreted the images. Results were compared with angiography (24 cases) and surgery (24 cases). Our results are compared with those of other investigators. RESULTS: Axial CT was the best method for detecting accessory arteries (24%) and early branching (10%); it also detected relevant venous and ureteral anatomy and incidental findings. The coronal and 3D images rarely added information that resulted in changed patient treatment. CT findings were concordant with those of digital angiography in 89% of kidneys and were 98% concordant with surgery. CONCLUSION: Helical CT can show arterial, venous, and ureteral anatomy and can also show important incidental findings. If only helical CT is used, a few small accessory vessels and an occasional renal artery stenosis may be missed. Axial images are generally diagnostic and may be supplemented by multiplanar and 3D images read concurrently.

Adult↗

CT colonography with three-dimensional problem solving for detection of colonic polyps.

OBJECTIVE: We performed CT colonography in patients referred for conventional colonoscopy, interpreted the axial images, and used commercially available software to reconstruct endoluminal perspective views to differentiate polyps from folds. SUBJECTS AND METHODS: We prospectively examined 44 patients (27 men and 17 women; mean age, 58 years old) with CT colonography by interpreting the axial images and using three-dimensional rendering for problem solving only. The CT scans were interpreted by two radiologists who were unaware of patients' histories as revealed by colonoscopic findings. The findings on colonography were compared with those of conventional colonoscopy to determine sensitivity, specificity, time spent on interpretation, and confidence of interpretation. RESULTS: Colonoscopy showed normal findings in 28 patients and 22 polyps in the remaining 16 patients. Six polyps were 8 mm or larger, three were 5-7 mm, and 13 were 5 mm or smaller. The findings of the two observers revealed an overall sensitivity of 50% and 38%, respectively, and a specificity of 93% and 86%, respectively. Sensitivity for polyps larger than 8 mm was 83% and specificity was 100% for both observers. The average amount of time spent on interpretation was 28 min 30 sec (range, 14-65 min). Both observers used the endoluminal view for differentiating folds from polyps in 23 (52%) of 44 patients, which had only minimal impact on interpretation time. CONCLUSION: CT colonography can be performed and the images interpreted using currently available hardware and software by initially using the axial images to search for polyps of significant size. Endoluminal views should be used only when necessary to help distinguish normal folds from fixed raised lesions that are suggestive of polyps.

Colonic Polyps↗

Small simulated polyps in pig colon: sensitivity of CT virtual colography.

PURPOSE: The authors evaluated computed tomographic (CT) virtual colography for the detection of simulated polyps under ideal conditions, as well as the effects on lesion conspicuity of (a) collimation, (b) table pitch, and (c) orientation of the colon lumen with respect to the gantry. MATERIALS AND METHODS: Pig colon was resected and cleansed, and polyps with diameters of 3, 7, and 10 mm were created. Each specimen was scanned with collimation of 5 and 7 mm and table pitch of 1.0, 1.6, and 2.0 at angles of 0 degrees, 45 degrees, and 90 degrees to the gantry. The initial two-dimensional (2D) images were reconstructed at 1-mm intervals (2D reconstructions), from which three-dimensional (3D) virtual colography images were generated. Polyp conspicuity on the initial and reconstructed 2D images and the 3D reconstructions was evaluated on a three-point scale: 0 = polyp not depicted, 1 = polyp faintly depicted, and 2 = polyp clearly depicted. RESULTS: The 10-mm-diameter polyp was clearly depicted (grade 2 conspicuity) on every initial and reconstructed 2D image and 3D reconstruction without regard to collimation, table pitch, or angle to the gantry. The 7-mm-diameter polyp was clearly depicted (grade 2 conspicuity) on every initial and reconstructed 2D image, but conspicuity on 3D reconstructions varied as the imaging parameters varied. The 3-mm-diameter polyp was faintly depicted (grade 1 conspicuity) on the initial and reconstructed 2D images and 3D reconstructions, but conspicuity varied on the 3D reconstructions as the imaging parameters varied. CONCLUSION: CT virtual colography helped detection of small mucosal polyps regardless of the angle of the colon lumen to the gantry at which they were obtained.

Animals↗