PubMed Health⌕ Search

Biomedical subjects

A H Engledow

Publications and source records attributed to A H Engledow.

5 recordsLinked to original sources

Day case laparoscopic incisional hernia repair is feasible, acceptable, and cost effective.

BACKGROUND: Day case surgery is increasingly performed in the United Kingdom. Laparoscopic techniques have increased the number of conditions suitable for a day surgical approach. Findings have shown that laparoscopic incisional hernia repair (LIHR) is superior to conventional open techniques. This study aimed to show that day case LIHR is safe, produces a good clinical outcome, and is cost effective. METHODS: Day case laparoscopic repair was performed for 31 consecutive patients (10 men; median age, 67 years; range, 39-80 years). Data were entered prospectively into a database. Patients were discharged within 8 h committed to a 10-day course of oral diclofenac 50 mg three times daily and 2 tablets of codydramol four times daily. Follow-up evaluation was by telephone consultation. Hospital costs for LIHR and open repair were compared. RESULTS: All procedures were completed laparoscopically on a day case basis. Additional unsuspected defects were found in eight cases (25.8%). The median mesh size was 140 cm2 (range, 25-375 cm2), and the median body mass index (BMI) was 28.7 kg/m2 (range, 20-37.1 kg/m2). Operations were performed or supervised by a single consultant surgeon (S.J.W.). Six postoperative seromas resolved spontaneously. Two port-site infections required oral antibiotics, and one diathermy pad burn healed with simple dressings. The median analgesia requirement was 7 days (range, 0-152 days). There were no recurrences during a median follow-up period of 15 months (range, 3-24 months). There was a saving of 616 pounds sterling per procedure. CONCLUSIONS: Day case laparoscopic repair of incisional hernias is feasible and safe and has a good clinical outcome. The hospital costs are less than for open techniques.

Adult↗

Laparoscopic incisional hernia repair with a self-centring suture.

BACKGROUND: Open incisional hernia repair is associated with high morbidity and recurrence rates. Laparoscopic approaches offer improved long-term results with low complication rates. METHODS: Laparoscopic repair was attempted in 117 consecutive patients (median age 68 (range 31-91) years, 50 men) undergoing 122 operations. A novel mesh centralization technique was employed. Data were recorded prospectively. Follow-up was by clinical review or telephone consultation. RESULTS: One hundred and eighteen procedures (96.7 per cent) were completed laparoscopically; four required conversion. Forty-one patients (35.0 per cent) had additional, unsuspected defects. The median mesh size was 225 (range 42-600) cm2. Median follow-up was 42 months. Small bowel enterotomy occurred in six patients. Fourteen postoperative seromas were successfully aspirated. Recurrence was detected in nine patients (7.7 per cent). One patient was readmitted with small bowel obstruction that settled with conservative management. There were no enterocutaneous fistulas. One patient died after operation from myocardial infarction. CONCLUSION: Laparoscopic incisional hernia repair using a self-centring suture provides good long-term results with low complication rates.

Adult↗

Acute lower limb ischaemia.

Salvage of the acutely ischaemic lower limb represents a large proportion of the emergency workload for the vascular surgeon. A successful outcome is dependent upon a careful clinical assessment and a prompt multidisciplinary approach to revascularization.

Acute Disease↗

Audit of a one-stop breast clinic--revisited.

BACKGROUND: A one-stop diagnostic service has been available for women with symptomatic breast disease at St Bartholomew's Hospital for 5 years and was originally audited in May 1993. In re-auditing the one-stop service our aim was to see if our practice had improved following the original audit and to look at the impact which these changes in practice had made to the service offered to the patient. METHODS: A prospective audit of 4 consecutive clinics was undertaken in November 1997. A total of 300 patients (59 new and 241 follow up) were seen in clinic in this time. The primary outcome measure concerned the completeness of triple assessment in the 40 patients who required one stop investigations, including mammography, ultrasonography and fine-needle aspiration cytology. In addition, mean time to initial consultation and level of awareness of the one-stop facility and its attendant time delay were measured. RESULTS: Of the 300 clinic attendees 40 (38 new, 2 follow-up) had one-stop investigations. As a result of the one-stop service being in practice, 36 patients (90%) had a definitive management decision made at their first outpatient visit. Of these 2 were symptomatic cancers, forming 5% of the workload. A total of 86% of the workload was benign. Four patients (10%) had equivocal results. The mean waiting time from designated appointment until surgical consultation was 36.7 minutes and was disappointingly unchanged from that of the previous audit. However this does not take into account the significant reduction in staffing levels which has occurred between the two periods of assessment. CONCLUSIONS: The initial audit identified a significant problem with time constraints, necessitating that a large number of patients with carcinomas return at a later date for further investigations. Booking only new patients at the beginning of clinic has provided a solution. Disappointingly, our figures do not show a significant improvement in mean waiting time compared with the previous audit, despite allowing GPs greater access of referral. Encouragingly, we have been able to maintain a similar standard of provision of care despite lower staffing levels and to implement the changes suggested by the original audit (thereby closing the audit loop).

Adolescent↗