[Quantification of cardiac function with multislice spiral CT using retrospective EKG-gating: comparison with MRI].

PURPOSE: To quantify left ventricular function derived from retrospectively ECG-gated multislice spiral CT (MSCT) data sets in comparison to MRI. MATERIALS AND METHODS: In 16 patients (14 males, 2 females, mean age 56.8 +/- 11.5 years), retrospectively ECG-gated MSCT angiography of the coronary arteries and breath-hold steady state free precession cine MRI were performed. From MSCT data-sets, 20 axial image series were reconstructed every 5 % of the RR interval. Multiplanar images were reformatted in the short axis orientation from axial images. End-systolic and end-diastolic images were selected. From these images end-systolic volume (ESV), end-diastolic volume (EDV) and stroke volume (SV) as well as the ejection fraction (EF) and myocardial mass (MM) were determined using the Simpson's method and compared with MRI. Furthermore, image quality was assessed for both imaging modalities using a four point grading scale. RESULTS: All parameters were found to have an excellent correlation between MSCT and MRI data (Pearson's correlation coefficient 0.95 - 0.99), without clinically relevant differences between both modalities. On average, the difference between both methods was 0.5 ml for ESV, 0.8 ml for EDV, 1.3 ml for SV, 0.9 % for EF and 2.3 g for MM. Image quality was slightly better for MRI (1.5 +/- 0.65) than for MSCT (1.64 +/- 0.74). CONCLUSION: Retrospectively ECG-gated MSCT angiography can not only visualize the coronary arteries but also enables precise quantification of the left ventricular function from the same MSCT data set.

Aged↗

Value of 3D-volume rendering in the assessment of coronary arteries with retrospectively ECG-gated multislice spiral CT.

PURPOSE: To assess the diagnostic value and measurement precision of 3D volume rendering technique (3D-VRT) from retrospectively ECG-gated multislice spiral CT (MSCT) data sets for imaging of the coronary arteries. MATERIAL AND METHODS: In 35 patients, retrospectively ECG-gated MSCT of the heart using a four detector row MSCT scanner with a standardized examination protocol was performed as well as quantitative X-ray coronary angiography (QCA). The MSCT data was assessed on segmental basis using 3D-VRT exclusively. The coronary artery diameters were measured at the origin of each main coronary branch and 1 cm, 3 cm and 5 cm distally. The minimum, maximum and mean diameters were determined from MSCT angiography and compared to QCA. RESULTS: A total of 353 of 525 (67.2%) coronary artery segments were assessable by MSCT angiography. The proximal segments were more often assessable when compared to the distal segments. Stenoses were detected with a sensitivity of 82.6% and a specificity of 92.8%. According to the Bland-Altman method the mean differences between QCA and MSCT ranged from -0.55 to 1.07 mm with limits of agreement from -2.2 mm to -2.7 mm. CONCLUSION: When compared to QCA, the ability of 3D-VRT to quantitatively assess coronary artery diameters and coronary artery stenoses is insufficient for clinical purposes.

Coronary Angiography↗

Detection of coronary calcifications: feasibility of dose reduction with a body weight-adapted examination protocol.

OBJECTIVE: The purpose of this study was to assess the applicability of individual body weight-adapted tube current time settings in multidetector CT for detection of coronary calcifications and to evaluate the effect of reducing the radiation dose on the coronary calcium score. SUBJECTS AND METHODS. One hundred patients underwent retrospectively ECG-gated MDCT for detection of coronary calcifications. First, fixed tube current time settings were used in 50 patients. Second, image noise corresponding to body weight-adapted tube current time settings was added to these images. Finally, body weight-adapted tube current time settings were applied to another 50 patients. For each patient group, the radiation dose was calculated. Coronary calcium scores were compared for the patient groups with the fixed tube current time settings with and without artificially added image noise. In all image series, image noise was assessed by a region-of-interest methodology. Image noise was analyzed using a regression analysis. RESULTS: The effective radiation dose was reduced by 11.6% for men and 24.8% for women using the body weight-adapted tube current time settings. There were no statistically significant changes in the coronary calcium score after the addition of artificial image noise (p = 0.84). Adaptation of the tube current time settings did not lead to a relevant increase in image noise. The radiation doses for the plotted noise-to-body weight (slope, 0.081) and noise-to-body mass index (slope, 0.378) ratios for the standard protocol proved relatively high for patients of lower weight. An improved noise-to-body weight (slope, 0.054) and noise-to-body mass index (slope, 0.190) ratio was achieved by application of the body weight-adapted tube current time settings, resulting in nearly constant image noise related to body weight. CONCLUSION: Individual body weight-adapted current time settings are applicable for coronary calcium scoring without a change of the coronary calcium score or relevant increase of the image noise.

Body Mass Index↗

Aneurysmal bone cyst: value of MR imaging and conventional radiography.

Our objective was to investigate the accuracy and the diagnostic value of different imaging features of primary aneurysmal bone cysts (ABC) in conventional radiographs and MRI. Conventional radiographs and MR images of 34 patients with a suspected aneurysmal bone cyst were reevaluated by six independent radiologists in a blinded fashion. Morphological features, MR signal characteristics, and contrast enhancement patterns were assessed. Diagnoses were correlated with histology. Sensitivity and specificity of the different imaging findings for each imaging technique were calculated. In 24 patients ABC was histologically proven. In 10 cases diagnoses other than ABC were established. Conventional radiography and MRI each demonstrated a sensitivity of 76.4 and 77.8% with a specificity of 55.0 and 66.7%, respectively. With combined use of both imaging modalities sensitivity and specificity increased to 82.6 and 70%, respectively. The ABC was significantly more often seen as circumscribed lesion with bone expansion, lobulation, septa, and pathological cortical bone reaction than those cases with different diagnoses. Septal contrast enhancement proved to be a useful MR imaging finding in suspected ABC. The combined use of conventional radiographs and MRI revealed the highest sensitivity in the diagnosis of ABC in relation to histology. Magnetic resonance imaging provides improved diagnostic specificity and valuable information on soft tissue changes.

Adolescent↗

[Percutaneous radiofrequency ablation of liver malignancies: first experience with a 200-W radiofrequency generator].

PURPOSE: To evaluate the effectiveness of a percutaneous radiofrequency ablation device, consisting of a LeVeen probe and a newly developed 200-W radiofrequency generator. MATERIAL AND METHOD: In 20 patients (9 male, 11 female), 30 primary and secondary liver malignancies were treated by CT-guided percutaneous radiofrequency ablation. The patients were separated in a potentially curable (n = 10) and a palliative (n,= 10) treatment group. The treatment was performed using an umbrella-shaped LeVeen probe with a diameter of 3.5 cm or 4 cm and a 200-W generator (Radiotherapeutics, Mountain View, CA, USA). All interventions were performed under general anesthesia by a standardized treatment protocol. The size of the lesions treated ranged from 2.2 x 2 x 2 cm to 10.8 x 10.1 x 10.5 cm. RESULTS: In all patients, the correct placement of the probe and radiofrequency ablation was technically successful. In two patients more than one treatment session was necessary to achieve the intended treatment result. In all patients of the potentially curable group a complete tumor necrosis could be achieved, whereas in the palliative treatment group complete tumor necrosis was only achievable in one patient. The achieved necrosis size ranged from 2.4 x 2.8 x 2.5 cm to 9.2 x 8 x 10.5 cm. In one patient a colon fistula was observed 4 weeks after treatment. No further complications were observed. The follow-up period ranges from 1 to 15 months (mean 4.5 months). CONCLUSION: By use of a powerful generator in combination with a LeVeen probe percutaneous treatment of even large liver tumors is possible. Radiofrequency ablation is a safe procedure for the minimal-invasive therapy of non resectable liver neoplasms.

Adult↗

[A differentiated approach to the diagnosis of pulmonary embolism and deep venous thrombosis using multi-slice CT].

PURPOSE: To establish a differentiated protocol for multi-slice CT (MSCT) examinations in cases of clinically suspected pulmonary embolism (PE) using pulmonary CT-angiography (CTA) and indirect CT-phlebography (CTP). MATERIALS AND METHODS: 161 patients with suspected PE were examined using an MSCT (SOMATOM Volume Zoom; Siemens, Forchheim, Germany). After intravenous administration of 120 ml of contrast material, a thin collimation chest-CT scan was performed (120 kV, 100 mAs, collimation: 4 x 1 mm). If PE was present, or previous examinations and clinical signs suggested deep venous thrombosis (DVT), a CTP was subsequently completed. CTPs were performed using a 4 x 5 mm protocol (120 kV, 170 mAs). Venous phase scanning, starting from the pelvic crest, was completed in the popliteal fossa three minutes after contrast material injection. In 73 extremities, CTP were compared to the results of ultrasound, phlebography and autopsy. Scan ranges were documented in all patients. Cumulative doses were calculated for male and female subgroups. RESULTS: 62 patients in our series suffered from PE and in 47 of these patients deep venous thrombosis was seen additionally. Of the 99 patients without PE, 47 also received indirect CTP. CTP confirmed the suspicion and extent of DVT in 8 patients. Only in 2 of 39 patients (5.1 %) was previously unknown DVT found, despite the exclusion of PE. Regarding DVT, sensitivity was 94.3 % and specificity was 92.1 % for indirect CTP. Cumulative chest CT doses averaged 3.3 mSv for males and 4.2 mSv for females, the calculated CTP dosage was 9.3 mSv (according to ICRP 60). CONCLUSIONS: The examination protocol presented is suitable for clinical usage in patients with suspected PE. If PE is confirmed, indirect CTP is justified, so that detailed information of the venous system can be obtained. However, the relatively high radiation dosage of an additional CTP requires a strict indication regiment in patients with a negative CTA.

Adult↗

MR signal intensity characteristics in Legg-Calvé-Perthes disease. Value of fat-suppressed (STIR) images and contrast-enhanced T1-weighted images.

PURPOSE: To evaluate the MR signal intensity characteristics in Legg-Calvé-Perthes disease on fat-suppressed (STIR) images and contrast-enhanced T1-weighted spin-echo images, and to develop criteria for the administration of contrast material. MATERIAL AND METHODS: Twenty children with Legg-Calvé-Perthes disease underwent conventional radiography and MR imaging of the hip utilizing fat-suppressed (STIR) sequences and T1-weighted spin-echo sequences before and after i.v. contrast administration. The signal intensity characteristics of the femoral head and the proximal femoral metaphysis were assessed retrospectively by two pediatric radiologists. RESULTS: Evaluation of the MR images revealed six different signal patterns within the femoral head: 1) isointense signal on all images; 2) complete signal void on all images; 3) hyperintense signal on STIR images with; or 4) without contrast enhancement on T1-weighted spin-echo images; 5) isointense signal on STIR images with; or 6) without contrast enhancement on T1-weighted images. Within the metaphysis three different signal patterns were differentiated. CONCLUSION: Combination of fat-suppressed (STIR) sequences and T1-weighted pre- and post-contrast sequences allows an accurate evaluation of Legg-Calvé-Perthes disease. In patients without signal alterations or complete signal loss on fat-suppressed and T1-weighted spin-echo images, administration of i.v. contrast is not necessary. In case of bone marrow edema on fat-supressed images, contrast-enhanced T1-weighted images are required to identify viable osseous fragments.

Adolescent↗

Multidetector CT of the spine in multiple myeloma: comparison with MR imaging and radiography.

OBJECTIVE: The purpose of this study was to compare multidetector CT (MDCT) of the thoracic and lumbar segments of the spine with MR imaging and conventional radiography for bone lesion detection and for evaluating the risk of vertebral fracture in multiple myeloma. SUBJECTS AND METHODS: Eighteen patients with multiple myeloma stage III (according to the criteria of Durie and Salmon) underwent MDCT, conventional radiography, and MR imaging of the lumbar and thoracic spine. MDCT was performed using a standard protocol with no contrast material. Source images were reconstructed using an effective slice thickness of 3 mm with an overlapping reconstruction increment (0.8 mm). Secondary coronal and sagittal multiplanar reformations were exclusively used for establishing the diagnosis. Findings were compared with those of MR imaging and conventional radiography. RESULTS: In all patients, coronal and sagittal multiplanar reformations depicted the extent of osseous destruction and provided detailed information about osseous infiltration and potential bone instability. Compared with conventional radiography, an additional 24 affected vertebrae, 15 additional vertebral fractures, and six vertebrae at further risk of fracture were detected on MDCT. Compared with MR imaging, three additional endangered vertebrae were detected on MDCT. MR imaging alone would have lead to an understaging of five (27.8%) of 18 patients. Using combined radiography and MR imaging, disease in three (16.7%) of 18 patients would have been understaged. CONCLUSION: MDCT seems to be preferable to conventional radiography in evaluating bone destruction in multiple myeloma. In combination with MR imaging, detailed information for staging these tumors is obtained. For the initial staging in patients with multiple myeloma, MDCT in combination with MR imaging seems to be the method of choice.

Aged↗

Cross-sectional imaging of primary osseous hemangiopericytoma.

The aim of this study was to assess cross-sectional imaging features and the value of CT and MRI in primary hemangiopericytoma of bone. In five patients with histologically proven primary osseous hemangiopericytoma CT and MR scans were evaluated retrospectively. Both CT and MRI were available in four patients each. In three patients both imaging techniques were available. On CT primary hemangiopericytoma of bone presents as an expansive lytic lesion with bone destruction and inhomogeneous contrast enhancement. Magnetic resonance imaging depicts osseous hemangiopericytoma as hyperintense lesion on T2-weighted images with intermediate signal intensity on T1-weighted images. Curvilinear tubular structures of signal void in the tumor matrix on T1-weighted images and corresponding hyperintense structures on T2-weighted and on fat-suppressed short tau inversion recovery images were present in three patients. Although cross-sectional imaging findings are non-specific, they add to the diagnosis and provide valuable information about the extent of bone destruction and local tumor spread in patients with primary osseous hemangiopericytoma. While CT demonstrates the extent of bone destruction best, MRI better visualizes medullary and soft tissue extension of the tumor. Curvilinear signal abnormalities support the diagnosis of hemangiopericytoma of bone. This imaging pattern is best visualized on fat-suppressed or contrast enhanced T1-weighted MR images.

Adult↗

Cross-sectional imaging patterns of desmoplastic fibroma.

The aim of this study was to work out the cross-sectional imaging characteristics of desmoplastic fibroma (DF). In 3 patients with histologically proven DF, the imaging characteristics obtained with cross-sectional techniques were reviewed retrospectively. Radiographs and CT scans were available in all patients, and plain and contrast-enhanced MR examinations in 2 patients. Compared with conventional radiographs, CT allowed more accurate assessment of the extent of bone destruction including cortical breakthrough and articular invasion. Intramedullary tumor growth and soft tissue extension was best detected with MRI. Apart from heterogeneity on MR images, DF displayed nonspecific low signal intensity on unenhanced T1-weighted images and an intermediate to high signal intensity including areas of low intensity on T2-weighted images. Desmoplastic fibroma showed a distinct, inhomogeneous gadolinium enhancement. Although cross-sectional imaging features of DF are nonspecific, some MR characteristics, such as inhomogeneous contrast enhancement and the presence of low-intensity regions on T2-weighted images, are helpful in determining the differential diagnosis. Cross-sectional imaging of DF is useful for local staging of the tumor because it provides valuable information about the extent of bone destruction as well as medullary and extraosseous spread.

Adolescent↗

[Automated image analysis of lateral roentgen images of the spine using anatomic models].

PURPOSE: Development of a software for fully automated image analysis of lateral lumbar spine X-rays. MATERIAL AND METHOD: Using the concept of active shape models, we developed a software that produces a form model of the lumbar spine from lateral lumbar spine radiographs and runs an automated image segmentation. This model is able to detect lumbar vertebrae automatically after the filtering of digitized X-ray images. The model was trained with 20 lateral lumbar spine radiographs with no pathological findings before we evaluated the software with 30 further X-ray images which were sorted by image quality ranging from one (best) to three (worst). There were 10 images for each quality. RESULTS: Image recognition strongly depended on image quality. In group one 52 and in group two 51 out of 60 vertebral bodies including the sacrum were recognized, but in group three only 18 vertebral bodies were properly identified. CONCLUSION: Fully automated and reliable recognition of vertebral bodies from lateral spine radiographs using the concept of active shape models is possible. The precision of this technique is limited by the superposition of different structures. Further improvements are necessary. Therefore standardized image quality and enlargement of the training data set are required.

Humans↗

[The influence of motion artifacts conditioned by reconstruction, on the coronary calcium score in multislice spiral CT].

UNLABELLED: The influence of motion artifacts conditioned by reconstruction, on the coronary calcium score in multislice spiral CT. PURPOSE: A major problem of the quantification of coronary calcifications is a high variability of the coronary calcium score between recurrent examinations and different observers. Aim of our study is to evaluate the influence of different RR-intervals on the coronary calcium score utilizing retrospectively gated Multislice Spiral CT (MSCT) data sets. MATERIALS AND METHOD: 50 consecutive patients underwent MSCT examination (Somatom Volume Zoom, Siemens, Forchheim, G) utilizing a standardized scan protocol (4 x 2.5 mm collimation, 3 mm increment, tube current 133 mAs, tube voltage 120 kV). Retrospectively gated image reconstruction was performed every 10 % of the RR interval. Coronary calcification was evaluated by the Agatston score. Coronary risk assessment was performed in all patients with image reconstruction beginning at 80 % of the RR interval. The reconstruction intervals with the least motion artifacts were identified and chosen as reference for a reevaluation of the coronary risk. The results of different reconstruction times were compared. RESULTS: The mean calcium score was 551.6. The calcium score varied between 512.2 (90 %) and 571.7 (70 %), depending on the image reconstruction interval. Compared to the mean calcium score a new classification of the coronary risk was necessary in 7/50 of the patients at 80 % reconstruction interval, and in 2/50 of the patients at 50 % of the RR interval, respectively. CONCLUSION: Movement of the coronary arteries at different image reconstruction intervals has an important influence on the coronary calcium score. Based on our data, we propose image reconstruction at 50 % of the RR interval for evaluation of the coronary calcium score by MSCT.

Adult↗

Individually adapted examination protocols for reduction of radiation exposure in chest CT.

RATIONALE AND OBJECTIVES: To develop a simple directive for the reduction of radiation exposure without loss of diagnostic information in routine chest CT examinations. METHODS: Two hundred fifty adult patients (164 male, 86 female) were entered into a prospective trial. All examinations were performed with a multislice CT technique (Somatom Volume Zoom, Siemens). Four groups of 50 patients each were scanned with patient-related specific parameters: individual mA-s values were derived from the estimated body weight: kilograms + 10, +/- 0, - 10, and - 20 mAs. The results were compared with those of 50 patients who were examined by a standard chest protocol by using the parameters 120 mAs and 140 kV. All other parameters including the tube voltage were kept constant. Subjective image quality was rated on a three-point scale: 1 = excellent, 2 = fair, 3 = nondiagnostic. In addition, objective criteria based on signal-to-noise measurements were assessed by using a region-of-interest methodology. RESULTS: Image quality was sufficient in all cases. Mean subjective gradings of image quality, based on soft-tissue window settings, were 1.1 for the 120-mAs protocol, 1.1 for the (body weight [kg] + 10) mAs protocol, 1.1 for the (body weight [kg] +/- 0) mAs protocol, 1.3 for the (body weight [kg] - 10) mAs protocol, and 1.2 for the (body weight [kg] - 20) mAs protocol. Objective criteria based on noise measurements showed mean +/- standard deviation values of 5.7 +/- 0.8 Hounsfield units (HU) for the 120-mAs protocol. For the reduced-dose protocols, values were calculated as 7.6 +/- 1.2 HU (group + 10), 7.9 +/- 1.3 HU (group +/- 0), 8.7 +/- 1.2 HU (group - 10), and finally 9.1 +/- 1.3 HU (group - 20). The best correlation for an entire subgroup was achieved with the - 10 protocol (body weight [kg] - 10) mAs, with nearly constant noise related to body weight in all patients. CONCLUSIONS: By deriving mAs values from body weight estimation, an individually adapted protocol for chest CT can be recommended and easily employed in a clinical setting. With an adaptation of the tube current-time product based on the estimated body weight of the patient - 10 (body weight [kg] - 10 mAs), a well-balanced examination without significant loss of information, even in soft-tissue window settings, can be performed with this particular scanner. For this adapted mAs protocol, a mean reduction of radiation exposure of 45% was achievable, compared with the standard protocol. A maximum decrease per case down to 31 mAs was obtained, without relevant loss of image quality. Therefore, for other types of CT scanners, analogous protocols may be adapted.

Adult↗

Silicosis-induced pulmonary artery stenosis: demonstration by MR angiography and perfusion MRI.

Silicosis is a common occupational disease. We present a 64-year-old male patient suffering from symptomatic silicosis due to compression of the pulmonary arteries by enlarged hilar lymph nodes. Clinical symptoms and diagnostic imaging modalities are described, with emphasis on cross-sectional imaging. MR angiography and perfusion MRI of the lung in silicosis are described, and their diagnostic value in pneumoconiosis is discussed.

Arterial Occlusive Diseases↗

Congenital pseudarthrosis of the tibia in pediatric patients: MR imaging.

OBJECTIVE: The purpose of this study was to describe the characteristics of congenital pseudarthrosis of the tibia on MR images of infants and children and to assess the value of MR imaging in evaluating this disease. CONCLUSION: MR imaging of congenital pseudarthrosis allows assessment of the type and extension of the disease. It is especially recommended for the evaluation of periosteal and soft-tissue changes near the pseudarthrosis.

Child, Preschool↗