PubMed Health⌕ Search

Biomedical subjects

A H Simpson

Publications and source records attributed to A H Simpson.

At least 19 recordsLinked to original sources

Use of non-degenerate human osteochondral tissue and confocal laser scanning microscopy for the study of chondrocyte death at cartilage surgery.

Although autologous osteochondral grafting has been widely applied in humans, most in vitro work has been on animal models. The aims of this study were to: (i) elaborate a full thickness human femoral condylar model using discard material from knee arthroplasty resections, and (ii) use this model to assess chondrocyte viability in response to surgical trauma. Homogeneous regions of human lateral femoral condyle bone-cartilage were procured from knee arthroplasty resections. These were graded prospectively, firstly by visual inspection, and then by confocal laser scanning microscopy (CLSM). Samples were subjected to tests of tissue hydration, including analysis of water content and swelling after excision from underlying bone. Surgical cuts were made in explants that were macroscopically and microscopically normal (i.e. Grade 0). Associated margins of death were assessed from both transverse and surface perspectives. Thirty-nine samples were obtained from anterior and distal femoral cuts (16 knees from 13 patients) for (1) macroscopic grading, (2) microscopic analysis, (3) analyses of water content as cut and on re-equilibration after excision from bone. Thirteen were Grade 0 on macroscopic viewing--however one showed fibrillation on microscopy and was therefore reassigned Grade 1. Grade 0 tissue had a water content of 73.8+/-0.38%, in agreement with control values from the literature. Tissues of Grades 2 and 3 were significantly (P=0.03, and P=0.004) more hydrated (76.0+/-0.59%, 76.7+/-0.99%) than Grade 0 tissue. Grade 0 tissue from the anterior cut did not swell significantly following excision from subchondral bone. However Grade 0 tissue from the distal cut showed a small but statistically significant (P=0.019) increase in water content (1.68+/-0.39%) following excision. With increasing grade there was increased tendency to swell off the bone (P<0.0001). Transverse imaging showed that the Acufex MP surgical harvester caused a greater margin of cell death (211+/-18.3 microm) in the superficial zone (SZ) than the mid-zone (50.5+/-13.6 microm; P=0.022), or SZ death from a scalpel cut (33.0+/-8.5 microm; P=0.0009). Similarly, in unfixed samples viewed from the surface perspective, the margin of death for the surgical harvester (277+/-7.2 microm) was significantly (P<0.0001) greater than that for the scalpel (38.8+/-7.2 microm). If macroscopically and microscopically non-degenerate, then human lateral femoral condylar cartilage from the anterior cut of knee resections has normal biophysical parameters (water content and lack of swelling on excision). The surgical harvester (Acufex), used in human osteochondral grafting, caused a substantial margin of cell death at the periphery of the graft, and the SZ appeared to be especially vulnerable. This effect may be important in terms of limiting the reparative capacity of the SZ. The harmful effect on viability is likely to impede lateral repair which is fundamental to subsequent structural and functional integrity.

Adult↗

Cutting-edge design to improve cell viability in osteochondral grafts.

INTRODUCTION: Autologous osteochondral grafting is in widespread use for focal defects of articular cartilage. There is major concern over the nature of the tissue bridging graft elements and graft/recipient cartilage. Chondrocyte viability is thought to be an important determinant of the quality of repair. The aim of the current study was to compare the zone of death for osteochondral grafts harvested with the commercially available Acufex, and an osteotome with a specially designed cutting-edge. MATERIALS/METHODS: The circular osteotomes were the Acufex 4.5mm MP (Smith & Nephew) and the Lissimore, which has a different cutting-tip geometry and sharpness. These implements were used to harvest osteochondral plugs from macroscopically non-degenerate human lateral condyle explants obtained from the anterior femoral cuts of knee replacement surgery. Confocal laser scanning microscopy with vital staining was used to quantify the zone of marginal chondrocyte death for the entire perimeter of the plugs. RESULTS: The increase in cartilage plug diameter (reference the osteotome minimal internal diameter) was significantly greater for the Acufex (Mann-Whitney; n=5; P=0.0079), with the diameter (mm) increasing by 0.49+/-0.03 (10.9%), compared with 0.16+/-0.02 (3.3%) for the Lissimore. Osteochondral plugs had a significantly (Mann-Whitney; n=5; P=0.0079) lower mean margin of cell death with the Lissimore osteotome (117.8+/-8.97 microm) than the Acufex MP (315.3+/-5.90 microm). CONCLUSIONS: Cutting-tip profile is an important factor in determining the extent of marginal death in circular osteochondral grafts. We have designed and assessed an alternative cutting-tip, which caused significantly less marginal death than the commercially available Acufex. We conclude that there is scope for improvement of osteochondral harvest techniques.

Aged↗

Elimination of transmissible spongiform encephalopathy infectivity and decontamination of surgical instruments by using radio-frequency gas-plasma treatment.

It has now been established that transmissible spongiform encephalopathy (TSE) infectivity, which is highly resistant to conventional methods of deactivation, can be transmitted iatrogenically by contaminated stainless steel. It is important that new methods are evaluated for effective removal of protein residues from surgical instruments. Here, radio-frequency (RF) gas-plasma treatment was investigated as a method of removing both the protein debris and TSE infectivity. Stainless-steel spheres contaminated with the 263K strain of scrapie and a variety of used surgical instruments, which had been cleaned by a hospital sterile-services department, were examined both before and after treatment by RF gas plasma, using scanning electron microscopy and energy-dispersive X-ray spectroscopic analysis. Transmission of scrapie from the contaminated spheres was examined in hamsters by the peripheral route of infection. RF gas-plasma treatment effectively removed residual organic residues on reprocessed surgical instruments and gross contamination both from orthopaedic blades and from the experimentally contaminated spheres. In vivo testing showed that RF gas-plasma treatment of scrapie-infected spheres eliminated transmission of infectivity. The infectivity of the TSE agent adsorbed on metal spheres could be removed effectively by gas-plasma cleaning with argon/oxygen mixtures. This treatment can effectively remove 'stubborn' residual contamination on surgical instruments.

Animals↗

Chondrocyte death associated with human femoral osteochondral harvest as performed for mosaicplasty.

BACKGROUND: Autologous osteochondral transfer is an option for the treatment of articular defects. However, there are concerns about graft integration and the nature of the tissue forming the cartilage-cartilage bridge. Chondrocyte viability at graft and recipient edges is thought to be an important determinant of the quality of repair. The purpose of the present study was to evaluate early cell viability at the edges of osteochondral grafts from ex vivo human femoral condyles. METHODS: Fresh human tissue was obtained from eleven knees at the time of total knee arthroplasty for the treatment of osteoarthritis. Osteochondral cylinders were harvested with use of a 4.5-mm-diameter mosaicplasty osteotome from regions of the anterolateral aspect of the femoral condyle that were macroscopically nondegenerate and histologically nonfibrillated. Plugs were assessed for marginal cell viability by means of confocal laser scanning microscopy. RESULTS: The diameter of the cartilaginous portion of the osteochondral plugs was a mean (and standard error of the mean) of 4.84 +/- 0.12 mm (as determined on the basis of three plugs). This value was approximately 300 microm greater than the measured internal diameter of the osteotome. There was a substantial margin of superficial zone cell death (mean thickness, 382 +/- 68.2 microm), with >99% cell viability seen more centrally (as determined on the basis of five plugs). Demiplugs were created by splitting the mosaicplasty explants with a fresh number-11 scalpel blade. The margin of superficial zone cell death at the curved edge was significantly greater than that at the site of the scalpel cut (390.3 +/- 18.8 microm compared with 34.8 +/- 3.2 microm; p = 0.0286). Similar findings were observed when the cartilage alone was breached and the bone was left intact, with the margin of superficial zone cell death being significantly greater than that obtained in association with the straight scalpel incision (268 +/- 38.9 microm compared with 41.3 +/- 13.4 microm; p = 0.0286). The margin of superficial zone cell death showed no increase during the time-period between fifteen minutes and two hours after plug harvest. A mathematical approximation of the mosaicplasty region suggested that early cell death of this magnitude affects about one third of the superficial graft area. CONCLUSIONS: The results of the present study suggest that mosaicplasty, while capable of transposing viable hyaline cartilage, is associated with an extensive margin of cell death that is likely to compromise lateral integration and articular reconstruction.

Aged↗

Growth factor expression during the development of atrophic non-union.

The aim of the study was to determine, for the first time, the distribution of expression of several important growth factors during the development of atrophic non-unions using an animal model. The sites of expression of TGFbeta, PDGF, FGFb, and BMP 2/4 were determined at the osteotomy sites of both normally healing bones and within atrophic non-unions at 1 and 8 weeks after operation using immunolocalization techniques. At 1 week after operation, the osteotomy gaps of the control group contained fracture haematoma and surrounding granulation tissue, whereas the osteotomy gaps of the non-union group contained only haematoma. The tissues of both the non-union and control groups demonstrated the same presence and distribution of growth factors. By 8 weeks after the operation, the control group osteotomy gaps were filled with bone within which the active osteoblasts stained positively for each of the growth factors. At 8 weeks, the osteotomy gaps of the non-union group contained only fibrous tissue, which failed to stain positively for any of the factors. These findings suggest that the development of atrophic non-union is not directly due to a lack of these four growth factors.

Animals↗

Toxic effect of rifampicin on human osteoblast-like cells.

We examined the effects of rifampicin on osteoblast-like cells derived from adult human bone in vitro. Cancellous bone was collected from five different individuals during elective orthopaedic operations and cultured in antibiotic-free media. Total DNA, 3H-thymidine incorporation and alkaline phosphatase (ALP) activity were measured after the cells were cultured for 4 days in media containing concentrations of rifampicin ranging from 0 to 1000 microg/ml. Mean total DNA was decreased at concentrations of 10 microg/ml and above in the cultures obtained from four out of five individuals but these decreases were significant in the cultures from only two individuals. 3H-thymidine incorporation, a more sensitive indicator of change in cell proliferation, and ALP activity were significantly decreased (P < 0.05) in all of the cultures containing 3 and 7 microg/ml, respectively. In the clinical setting, serum concentrations of rifampicin often exceed 10 microg/ml after systemic administration. The present study has shown that rifampicin, at these concentrations, can inhibit the proliferation of osteoblast-like cells in vitro. Further studies should be carried out to assess whether rifampicin is detrimental to the bone repair process in vivo.

Adolescent↗

Osteoprogenitor cells of mature human skeletal muscle tissue: an in vitro study.

The presence of osteogenic progenitors in human skeletal muscle is suggested by the formation of ectopic bone in clinical and experimental conditions, but their direct identification has not yet been demonstrated. The aims of this study were to identify osteogenic progenitor cells in human skeletal muscle tissue and to expand and characterize them in culture. Specimens of gracilis and semitendinosus muscle were obtained from young adults and digested to separate the connective tissue and satellite cell fractions. The cells were cultured and characterized morphologically and immunohistochemically using antibodies known to be reactive with primitive osteoprogenitor cells, pericytes, intermediate filaments, and endothelial cells. Alkaline phosphatase activity and osteocalcin gene expression were also determined. In the early stages of culture, the connective tissue cells obtained were highly positive for primitive osteoprogenitor cell and for pericyte markers. Alkaline phosphatase activity was detectable at early stages of culture and rose as a function of time, whereas primitive osteoprogenitor cell markers declined and osteocalcin mRNA expression became detectable by reverse transcriptase-polymerase chain reaction (RT-PCR). It is shown that human skeletal muscle connective tissue contains osteogenic progenitor cells. Their identification as pericytes, perivascular cells with established osteogenic potential, suggests a cellular link between angiogenesis and bone formation in muscle tissue. These cells are easily cultured and expanded in vitro by standard techniques, providing an alternative source of osteogenic progenitor cells for possible cell-based therapeutic use in certain conditions.

Actins↗

Chronic osteomyelitis. The effect of the extent of surgical resection on infection-free survival.

We studied prospectively a consecutive series of 50 patients with chronic osteomyelitis. Patients were allocated to the following treatment groups: 1) wide resection, with a clearance margin of 5 mm or more; 2) marginal resection, with a clearance margin of less than 5 mm; and 3) intralesional biopsy, with debulking of the infected area. All patients had a course of antibiotics, intravenously for six weeks followed by orally for a further six weeks. No patients in group 1 had recurrence. In patients treated by marginal resection (group 2), 8 of 29 (28%) had recurrence. All patients who had debulking had a recurrence within one year of surgery. We performed a survival analysis to determine the time of the recurrence of infection. In group 2 there was a higher rate of recurrence in type-B hosts (p < 0.05); no type-A hosts had recurrence. This information is of use in planning surgery for chronic osteomyelitis.

Adolescent↗

Skin closure after acute shortening.

Z-plasty is used to lengthen scars and wounds. We describe the use of a modified technique to shorten wounds in ten consecutive patients undergoing acute shortening of a limb as part of an Ilizarov procedure. The modified technique gave good exposure, easy closure of the wound and fewer problems with healing than standard incisions.

Bone Lengthening↗

Loss of knee range of motion in leg lengthening.

STUDY DESIGN: Prospective longitudinal study. OBJECTIVE: To determine factors predictive of loss of movement in a cohort of patients undergoing femoral lengthening. BACKGROUND: Loss of joint movement due to poor adaptation of the muscle is a major problem during limb lengthening but remains poorly documented in the literature. METHODS AND MATERIALS: A validated technique using a modified goniometer was used to measure knee motion. Measurements were taken before surgery, prelengthening, during lengthening, and at 6 and 12 months post frame removal. The subjects were 35 patients with a mean age of 22 years (+/-12.8 years), 23 men and 12 women, undergoing femoral lengthening by the Ilizarov method. RESULTS: The pattern of recovery of knee range of movement that was observed showed that 88% of knee flexion was regained by 6 months, 92% of patients regained their knee flexion by 12 months, and 97% by 18 months. Significant loss of knee flexion occurred in the latent period prior to lengthening, mean loss 79 degrees (+/-22.8 degrees). All patients regained full knee extension by the end of lengthening, but 2 patients who had fixed flexion deformities of > 40 degrees developed posterior subluxation of the knee. CONCLUSIONS: The unexpected loss of movement observed in the prelengthening period indicates that physical therapy efforts must be directed to this phase in order to accelerate the recovery of joint range and reduce the muscle-related complications that can occur during limb lengthening.

Adolescent↗

Metabolic activity of a new atrophic nonunion model in rabbits.

The aetiology of atrophic nonunions is not well understood: they are often thought to be nonreactive and metabolically inactive. Investigation of their biological processes is hampered by the lack of a useful animal model. Current models involve either wide segmental excision of the diaphysis or interposition of Silastic to impede the normal healing processes. neither of which resembles the clinical situation. We therefore aimed to establish a model of atrophic nonunion that more closely resembles the clinical situation and to use this model to evaluate the metabolic activity of the gap tissue of the nonunion. A simple and reliable model of atrophic nonunion has been developed in rabbits. It more closely represents the clinical situation by avoiding large segmental excisions and the interposition of foreign materials. Clinical, radiological, and histological data support the diagnosis of atrophic nonunion in the model. The concentration of adenosine triphosphate in the gap tissue of the nonunion served as a marker of metabolic activity. The gap tissue of established atrophic nonunions had a significantly higher concentration of adenosine triphosphate than did the control specimens. In this model, the gap tissue is metabolically active; therefore, under certain conditions, it may be possible to induce union if the correct stimulus is provided.

Adenosine Triphosphate↗

Anatomical effects of periosteal elevation.

Research that involves harvesting the periosteum is common. The exact technique of harvesting is rarely described; however, it may be of vital importance because techniques may vary in their ability to raise the osteogenic cambial layer, which is reported to be tightly adherent to the underlying cortex. This study was performed to define how the cambial and fibrous layers of the periosteum are affected by different techniques of stripping. The periosteum was raised from the tibia and the humerus of adult rabbits with four stripping techniques. The stripped bone surface was examined histologically and with a scanning electron microscope to determine whether the fibrous and cambial layers of the periosteum had been removed and whether there had been damage to the underlying cortex. The results from the two anatomical sites were the same. Raising the periosteum with cortical bone chips (shingling) or with a periosteal elevator removed both layers of the periosteum and caused considerable damage to the surface of the cortex. Raising the periosteum with a sharp scalpel or by simply pulling it off removed the fibrous layer but left the osteogenic layer intact adherent to the cortex. We conclude that some techniques of periosteal elevation fail to harvest the osteogenic layer and therefore may lead to unexpected experimental results. We suggest that authors describe the exact technique of periosteal stripping that was employed.

Animals↗

Tissues formed during distraction osteogenesis in the rabbit are determined by the distraction rate: localization of the cells that express the mRNAs and the distribution of types I and II collagens.

An experimental model of leg lengthening was used to study the morphology of, the collagenous proteins present, and the collagen genes expressed in the regenerating tissue following 20% lengthening at four different distraction rates. At a distraction rate of 0.3 mm/day (8 weeks distraction), the regenerate consists of intramembranous bone and localized areas of fibrocartilage. At rates of 0.7 (4 weeks) and 1.3 mm/day (2 weeks), the bone that grows from the cut ends of the cortical bone is separated by fibrous tissue and cartilage is present. At 2.7 mm/day (1 week), only fibrous tissue and sparse bone are present. Type I collagen is present in the matrices around the cells expressing its mRNA and similarly, type II collagen is located around the chondrocytes. Type I collagen mRNA is expressed predominantly by the fibroblasts in the fibrous tissue, the bone surface cells and to a reduced extent by the osteocytes. Type II collagen mRNA is expressed by chondrocytes. The results suggest that osteoblasts and chondrocytes within the regenerate originate from the same pool of progenitor cells, and the differentiation of these cells and the expression of types I and II collagen genes are altered by different rates of distraction. These observations suggest that the optimal rate of distraction in the model is 0.7 mm/day.

Animals↗

Stiffness, strength and healing assessment in different bone fractures--a simple mathematical model.

External fixators can only be removed safely when fractures have healed sufficiently to restore mechanical integrity to the bone. A bending stiffness of 15 N m/ degrees has been suggested as a means of estimating mechanical integrity. To examine whether this end point stiffness value can be applied to all fractures, the present study examined the degree of variability in predicted stiffness and strength that arises from variations in bone dimensions. Results imply that there is no common value for the end-point of bending stiffness in different bones. At an end point value of 15 N m/degrees, the maturity of the fracture repair tissue (represented by its elastic modulus) can vary 500-fold between an adult femur with a 0.5-mm gap to a child's mid diaphyseal tibia with a 1.0-mm gap. Fortunately, the strength does not vary by as large an extent as the modulus. However, even though two fractures each have reached a stiffness of 15 N m/degrees, a fracture in a bone of 50 mm diameter may exhibit only 60% of the strength of repair in a bone of 30 mm diameter. Therefore, caution should be exercised when using the bending stiffness as an end point indicator for different bones.

Adult↗

Advantages and disadvantages of pinless external fixation.

The AO pinless external fixator (PEF) uses trocar tipped clamps to grip the outer tibial cortex rather than pins to transfix it. Its main advantage is to avoid further contamination of the medullary canal in open tibial fractures where a nail may subsequently be used. We tested the anatomical safety of this device and its effect on plastic surgical procedures compared with a standard unilateral external fixator (UEF).The PEF and UEF were placed on two amputated limbs which were then dissected. Structures at risk were traced on ten cadaver limbs. We found that important anatomical structures were endangered by the PEF and that safe zones could not always be defined. The UEF avoided these structures. Plastic surgical approaches were made more difficult by the PEF which imposed limitations on local flap design and endangered the arterial perforators which supply them. We conclude that safety is compromised by the PEF because margins for error are small. It poses additional problems in soft tissue reconstruction and highlights the need for co-operation between plastic surgical and orthopaedic teams in choice of fixation device.

Cadaver↗

A murine model of distraction osteogenesis.

Distraction osteogenesis is both a valuable clinical technique and a useful tool for investigating the basic mechanisms involved in bone tissue regeneration. Here we describe the development of a murine model of this procedure that can be used in transgenic animals to investigate the role of specific genes in tissue regeneration. Ring fixators were applied to the lower leg of 12 normal adult male mice. An osteotomy was made in the diaphysis of the tibia, and 7 days after the operation the bone fragments were distracted by 0.25 mm twice a day for 10 days. Specimens were examined immediately at the end of distraction and after 14-70 days of consolidation. At the end of distraction, the distraction gap was filled with fibroblast-like cells arranged longitudinally. After 14 days of consolidation, there was radiographical evidence of bone formation in the distraction gap and, after 28 days of consolidation, the bone fragments were fused with regenerated bone. By 70 days of consolidation, the regenerated bone had been almost completely remodeled and the intramedullary canal reestablished. This study is the first to report consolidation of the distraction gap with regenerated bone in a murine model of distraction.

Animals↗

Comparison of fluorescent single-strand conformation polymorphism analysis and denaturing high-performance liquid chromatography for detection of EXT1 and EXT2 mutations in hereditary multiple exostoses.

EXT1 and EXT2 are two genes responsible for the majority of cases of hereditary multiple exostoses (HME), a dominantly inherited bone disorder. In order to develop an efficient screening strategy for mutations in these genes, we performed two independent blind screens of EXT1 and EXT2 in 34 unrelated patients with HME, using denaturing high-performance liquid chromatography (DHPLC) and fluorescent single-strand conformation polymorphism analysis (F-SSCP). The mutation likely to cause HME was found in 29 (85%) of the 34 probands: in 22 of these (76%), the mutation was in EXT1; seven patients (24%) had EXT2 mutations. Nineteen of these disease mutations have not been previously reported. Of the 42 different amplicon variants identified in total in the cohort, 40 were detected by DHPLC and 39 by F-SSCP. This corresponds to mutation detection efficiencies of 95% and 93% respectively. We have also found that we can confidently distinguish between different sequence variants in the same fragment using F-SSCP but not DHPLC. In light of this, and the similarly high sensitivities of the two techniques, we propose to continue screening with F-SSCP.

Chromatography, High Pressure Liquid↗

Fracture after distraction osteogenesis.

We reviewed 173 patients undergoing distraction osteogenesis to determine the incidence, location and timing of fractures occurring as a complication of the procedure. There were 17 fractures in 180 lengthened segments giving an overall rate of fracture of 9.4%. Unexpectedly, the pattern and location of the fractures were very variable; six were within the regenerate itself, six at the junction between the regenerate and the original bone and five at distant sites in the limb. Of those occurring in the regenerate, five were noted to be associated with compression and partial collapse of the regenerate. In three patients collapse and deformity developed gradually in the distracted segment over the six months after removal of the frame. The method of treatment of these fractures should be chosen to take into account multiple factors, which are additional and often different from those to be considered during management of acute traumatic injuries. Internal fixation appears to be most appropriate for displaced fractures, although in small children, or in those in whom there has been, or is, infection of the screw tracks, a new period of treatment using external fixation may be needed. Fixation by intramedullary nailing was associated with a risk of infection, even if screw tracks were assessed as healthy at the time of insertion of the nail. Internal fixation with the use of plates is safe for displaced, unstable fractures in children.

Adult↗