Dartmouth's next generation EIS system: preliminary hardware considerations.

Our previous system covered the frequency range of 0 to 1 MHz. In this new design we propose to cover the range from 0 to 10 MHz. The higher frequencies have forced us to reconsider several design decisions in view of both the physics of the problem and the performance of available electronic components. In this presentation we examine in detail the constraints faced by the designer, starting from wiring consideration to measurement techniques. We will also present the solutions we selected to overcome the limitations we discovered. The problems include phase detection, amplitude measurements, system organization and layout and finally system calibration.

Breast Neoplasms↗

Modeling of retraction and resection for intraoperative updating of images.

OBJECTIVE: Intraoperative tissue deformation that occurs during the course of neurosurgical procedures may compromise patient-to-image registration, which is essential for image guidance. A new approach to account for brain shift, using computational methods driven by sparsely available operating room (OR) data, has been augmented with techniques for modeling tissue retraction and resection. METHODS: Modeling strategies to arbitrarily place and move an intracranial retractor and to excise designated tissue volumes have been implemented within a computationally tractable framework. To illustrate these developments, a surgical case example, which uses OR data and the preoperative neuroanatomic image volume of the patient to generate a highly resolved, heterogeneous, finite-element model, is presented. Surgical procedures involving the retraction of tissue and the resection of a left frontoparietal tumor were simulated computationally, and the simulations were used to update the preoperative image volume to represent the dynamic OR environment. RESULTS: Retraction and resection techniques are demonstrated to accurately reflect intraoperative events, thus providing an approach for near-real-time image-updating in the OR. Information regarding subsurface deformation and, in particular, changing tumor margins is presented. Some of the current limitations of the model, with respect to specific tissue mechanical responses, are highlighted. CONCLUSION: The results presented demonstrate that complex surgical events such as tissue retraction and resection can be incorporated intraoperatively into the model-updating process for brain shift compensation in high-resolution preoperative images.

Brain Neoplasms↗

Electrical impedance imaging at multiple frequencies in phantoms.

We have recently built and tested a 32 channel, multi-frequency (1 kHz to 1 MHz) voltage mode system to investigate electrical impedance spectroscopy (EIS) imaging. We completed a series of phantom experiments to define the baseline imaging performance of our system. Our phantom consisted of a plastic circular tank (20 cm diameter) filled with 0.9% aqueous NaCl solution. Conductors and nonconductors of decreasing width (W5: 3.4 cm, W4: 2.54 cm, W3: 0.95 cm, W2: 0.64 cm and WI: 0.32 cm) were positioned at various distances from the tank edge (1 cm, 2 cm, 4 cm and 8 cm). The results suggest that the detection of objects less than 1 cm in width is limited to the first 1 to 2 cm from the tank edge for absolute images, but this depth can extend to 8 cm in difference images. Larger 3.4 cm wide objects can be detected in absolute images at depths up to 8 cm from the tank edge. Generally, conductor images were clearer than their nonconductor counterparts. Not only did electrode artefacts lessen as the frequency increased, but the system's maximum resolution was attained at the highest operating frequencies. Although the system recovered the value of the electrical conductivity at the correct order of magnitude, it tended to smooth out large property discontinuities. The calculated electrical permittivity in these phantom studies was inconclusive due to the presence of electrode artefacts.

Electric Impedance↗

Multifrequency electrical impedance imaging: preliminary in vivo experience in breast.

We have deployed a recently completed spectroscopic electrical impedance tomography (EITS) imaging system in a small series of women (13 participants accrued to date) in order to investigate the feasibility of delivering EITS breast examinations on a routine basis. Hardware is driven with sinusoidally varying spatial patterns of applied voltage delivered to 16 electrodes over the 10 kHz to 1 MHz spectral range using a radially translating interface which couples the electrodes to the breast through direct contact. Imaging examinations have consisted of the acquisition of multi-channel measurements at ten frequencies on both breasts. Participants lie prone on an examination table with the breast to be imaged pendant in the electrode array that is located below the table. Examinations were comfortable and easy to deliver (about 10 minutes per breast including electrode-positioning time). Although localized near-surface electrode artefacts are evident in the acquired images, several findings have emerged. Permittivity images have generally been more informative than their conductivity counterparts, except in the case of fluid-filled cysts. Specifically, the mammographically normal breast appears to have characteristic absolute EITS permittivity and conductivity images that emerge across subjects. Structural features in the EITS images have correlated with limited clinical information available on participants with benign and malignant abnormality, cysts and scarring from previous lumpectomy and follow-up radiation therapy. Several cases from this preliminary experience are described.

Breast↗

Trauma and inflammation modulate lymphocyte localization in vivo: quantitation of tissue entry and retention using indium-111-labeled lymphocytes.

OBJECTIVE: Determine the in vivo localization pattern of indium-111-labeled lymphocytes after a standardized extremity injury or standardized laparotomy and after sterile inflammation of the central nervous system. DESIGN: Prospective animal study with concurrent controls. SETTING: Animal research laboratory. SUBJECTS: Male Lewis rats weighing 150-175 g. INTERVENTIONS: Indium-111-labeled splenic lymphocytes were injected into animals after a standardized hind limb trauma or laparotomy and after induction of sterile central nervous system inflammation. MEASUREMENTS AND MAIN RESULTS: Lymphoid and non-lymphoid organs were removed at fixed intervals after lymphocyte injection and the proportion of injected lymphocytes/gram of tissue was determined using a quantitative radionuclide calculation. Results from treated animals were compared with results from untreated control animals. Muscle injury caused early localization of lymphocytes to injured hind limbs, liver, and spleen compared with controls, whereas laparotomy decreased lymphocyte localization in the thymus and colon. Encephalitis increased localization to the central nervous system with no effect on other tissues. CONCLUSIONS: These results identify a sensitive method to track in vivo leukocyte localization and specifically demonstrate that lymphocyte localization is altered in both traumatic and nontraumatic models of inflammation.

Animals↗

A multichannel continuously selectable multifrequency electrical impedance spectroscopy measurement system.

There is increasing evidence that alterations in the electrical property spectrum of tissues below 10 MHz is diagnostic for tissue pathology and/or pathophysiology. Yet, the complexity associated with constructing a high-fidelity multichannel, multifrequency data acquisition instrument has limited widespread development of spectroscopic electrical impedance imaging concepts. To contribute to the relatively sparse experience with multichannel spectroscopy systems this paper reports on the design, realization and evaluation of a prototype 32-channel instrument. The salient features of the system include a continuously selectable driving frequency up to 1 MHz, either voltage or current source modes of operation and simultaneous measurement of both voltage and current on each channel in either of these driving configurations. Comparisons of performance with recently reported fixed-frequency systems is favorable. Volts dc (VDC) signal-to-noise ratios of 75-80 dB are achieved and the noise floor for ac signals is near 100 dB below the signal strength of interest at 10 kHz and 60 dB down at 1 MHz. The added benefit of being able to record multispectral information on source and sense signal amplitudes and phases has also been realized. Phase-sensitive detection schemes and multiperiod undersampling techniques have been deployed to ensure measurement fidelity over the full bandwidth of system operation.

Calibration↗

In vivo quantification of a homogeneous brain deformation model for updating preoperative images during surgery.

Clinicians using image-guidance for neurosurgical procedures have recently recognized that intraoperative deformation from surgical loading can compromise the accuracy of patient registration in the operating room. While whole brain intraoperative imaging is conceptually appealing it presents significant practical limitations. Alternatively, a promising approach may be to combine incomplete intraoperatively acquired data with a computational model of brain deformation to update high resolution preoperative images during surgery. The success of such an approach is critically dependent on identifying a valid model of brain deformation physics. Towards this end, we evaluate a three-dimensional finite element consolidation theory model for predicting brain deformation in vivo through a series of controlled repeat-experiments. This database is used to construct an interstitial pressure boundary condition calibration curve which is prospectively tested in a fourth validation experiment. The computational model is found to recover 75%-85% of brain motion occurring under loads comparable to clinical conditions. Additionally, the updating of preoperative images using the model calculations is presented and demonstrates that model-updated image-guided neurosurgery may be a viable option for addressing registration errors related to intraoperative tissue motion.

Animals↗

In vivo modeling of interstitial pressure in the brain under surgical load using finite elements.

Current brain deformation models have predominantly reflected solid constitutive relationships generated from empirical ex vivo data and have largely overlooked interstitial hydrodynamic effects. In the context of a technique to update images intraoperatively for image-guided neuronavigation, we have developed and quantified the deformation characteristics of a three-dimensional porous media finite element model of brain deformation in vivo. Results have demonstrated at least 75-85 percent predictive capability, but have also indicated that interstitial hydrodynamics are important. In this paper we investigate interstitial pressure transient behavior in brain tissue when subjected to an acute surgical load consistent with neurosurgical events. Data are presented from three in vivo porcine experiments where subsurface tissue deformation and interhemispheric pressure gradients were measured under conditions of an applied mechanical deformation and then compared to calculations with our three-dimensional brain model. Results demonstrate that porous-media consolidation captures the hydraulic behavior of brain tissue subjected to comparable surgical loads and that the experimental protocol causes minimal trauma to porcine brain tissue. Working values for hydraulic conductivity of white and gray matter are also reported and an assessment of transient pressure gradient effects with respect to deformation is provided.

Animals↗

A computational model for tracking subsurface tissue deformation during stereotactic neurosurgery.

Recent advances in the field of stereotactic neurosurgery have made it possible to coregister preoperative computed tomography (CT) and magnetic resonance (MR) images with instrument locations in the operating field. However, accounting for intraoperative movement of brain tissue remains a challenging problem. While intraoperative CT and MR scanners record concurrent tissue motion, there is motivation to develop methodologies which would be significantly lower in cost and more widely available. The approach we present is a computational model of brain tissue deformation that could be used in conjunction with a limited amount of concurrently obtained operative data to estimate subsurface tissue motion. Specifically, we report on the initial development of a finite element model of brain tissue adapted from consolidation theory. Validations of the computational mathematics in two and three dimensions are shown with errors of 1%-2% for the discretizations used. Experience with the computational strategy for estimating surgically induced brain tissue motion in vivo is also presented. While the predicted tissue displacements differ from measured values by about 15%, they suggest that exploiting a physics-based computational framework for updating preoperative imaging databases during the course of surgery has considerable merit. However, additional model and computational developments are needed before this approach can become a clinical reality.

Animals↗

Nonactive antenna compensation for fixed-array microwave imaging: Part II--Imaging results.

Model-based imaging techniques utilizing microwave signal illumination rely heavily on the ability to accurately represent the wave propagation with a suitable numerical model. To date, the highest quality images from our prototype system have been achieved utilizing a single transmitter/single receiver measurement system where both antennas are manually repositioned to facilitate multiple illuminations of the imaging region, thus requiring long data acquisition times. In an effort to develop a system that can acquire data in a real time manner, a 32-channel network has been fabricated with all ports capable of being electronically selected for either transmit or receive mode. The presence of a complete array of antenna elements at data collection time perturbs the field distributions being measured, which can subsequently degrade the image reconstruction due to increased data-model mismatch. Incorporating the nonactive antenna-compensation model from Part I of this paper into our hybrid element near field image reconstruction algorithm is shown to restore image quality when fixed antenna-array data acquisition is used. Improvements are most dramatic for inclusions located in near proximity to the antenna array itself, although cases of improvement in the recovery of centered heterogeneities are also illustrated. Increases in the frequency of illumination are found to warrant an increased need for nonactive antenna compensation. Quantitative measures of recovered inclusion shape and position reveal a systematic improvement in image reconstruction quality when the nonactive antenna-compensation model is employed. Improvements in electrical property value recovery of localized heterogeneities are also observed. Image reconstructions in freshly excised breast tissue illustrate the applicability of the approach when used with our two-dimensional microwave imaging system.

Algorithms↗

Model-updated image guidance: initial clinical experiences with gravity-induced brain deformation.

Image-guided neurosurgery relies on accurate registration of the patient, the preoperative image series, and the surgical instruments in the same coordinate space. Recent clinical reports have documented the magnitude of gravity-induced brain deformation in the operating room and suggest these levels of tissue motion may compromise the integrity of such systems. We are investigating a model-based strategy which exploits the wealth of readily-available preoperative information in conjunction with intraoperatively acquired data to construct and drive a three dimensional (3-D) computational model which estimates volumetric displacements in order to update the neuronavigational image set. Using model calculations, the preoperative image database can be deformed to generate a more accurate representation of the surgical focus during an operation. In this paper, we present a preliminary study of four patients that experienced substantial brain deformation from gravity and correlate cortical shift measurements with model predictions. Additionally, we illustrate our image deforming algorithm and demonstrate that preoperative image resolution is maintained. Results over the four cases show that the brain shifted, on average, 5.7 mm in the direction of gravity and that model predictions could reduce this misregistration error to an average of 1.2 mm.

Adolescent↗

Updated neuroimaging using intraoperative brain modeling and sparse data.

A strategy to update preoperative imaging for image-guided surgery using readily available intraoperative information has been developed and implemented. A patient-specific three-dimensional finite element model of the brain is generated from preoperative MRI and used to simulate deformation resulting from multiple surgical processes. Intraoperatively obtained sparse imaging data, such as from digital cameras or ultrasonography, is then used to prescribe the displacement of selected points within the model. Interpolation to the resolution of preoperative imaging may then be performed based upon the model. The algorithms for generation of the finite element model and for its subsequent deformation have been successfully validated using a pig brain model, and preliminary clinical application in the operating room has demonstrated feasibility.

Algorithms↗

Coregistered ultrasound as a neurosurgical guide.

INTRODUCTION: The dynamic nature and three dimensionality of ultrasound data can be utilized to enhance the capabilities of image guidance systems. METHODS: Coregistration of ultrasound data was done using an electromagnetic digitizer, and subsequent ultrasound images were correlated with preoperative MRI studies. Thirty-two patients undergoing craniotomy were investigated in this manner. RESULTS: Phantom testing done with a rigid stylus and 3D ultrasound tracker demonstrated an accuracy of 1.36 +/- 1.67 mm in determining the location of a point. Thirty-two clinical cases were coregistered without difficulty. CONCLUSION: Coregistered ultrasound is a useful methodology that can aid in neuronavigation.

Brain↗

Intraoperatively updated neuroimaging using brain modeling and sparse data.

OBJECTIVE: Image-guided neurosurgery incorporating preoperatively obtained imaging information is subject to spatial error resulting from intraoperative brain displacement and deformation. A strategy to update preoperative imaging using readily available intraoperative information has been developed and implemented. METHODS: Preoperative magnetic resonance imaging is used to generate a patient-specific three-dimensional finite element model of the brain by which deformation resulting from multiple surgical processes may be simulated. Sparse imaging data obtained subsequently, such as from digital cameras or ultrasound, are then used to prescribe the displacement of selected points within the model. Based on the model, interpolation to the resolution of preoperative imaging may then be performed. RESULTS: The algorithms for generation of the finite element model and for its subsequent deformation were successfully validated using a pig brain model. In these experiments, the method recovered 84% of the intraoperative shift resulting from surgically induced tissue motion. Preliminary clinical application in the operating room has demonstrated feasibility. CONCLUSION: A strategy by which intraoperative brain deformation may be accounted for has been developed, validated in an animal model, and demonstrated clinically.

Adult↗

Intraoperative brain shift and deformation: a quantitative analysis of cortical displacement in 28 cases.

OBJECTIVE: A quantitative analysis of intraoperative cortical shift and deformation was performed to gain a better understanding of the nature and extent of this problem and the resultant loss of spatial accuracy in surgical procedures coregistered to preoperative imaging studies. METHODS: Three-dimensional feature tracking and two-dimensional image analysis of the cortical surface were used to quantify the observed motion. Data acquisition was facilitated by a ceiling-mounted robotic platform, which provided a number of precision tracking capabilities. The patient's head position and the size and orientation of the craniotomy were recorded at the start of surgery. Error analysis demonstrated that the surface displacement measuring methodology was accurate to 1 to 2 mm. Statistical tests were performed to examine correlations between the amount of displacement and the type of surgery, the nature of the cranial opening, the region of the brain involved, the duration of surgery, and the degree of invasiveness. RESULTS: The results showed that a displacement of an average of 1 cm occurred, with the dominant directional component being associated with gravity. The mean displacement was determined to be independent of the size and orientation of the cranial opening. CONCLUSION: These data suggest that loss of spatial registration with preoperative images is gravity-dominated and of sufficient extent that attention to errors resulting from misregistration during the course of surgery is warranted.

Adult↗

Microwave imaging for tissue assessment: initial evaluation in multitarget tissue-equivalent phantoms.

A prototype microwave imaging system is evaluated for its ability to recover two-dimensional (2-D) electrical property distributions under transverse magnetic (TM) illumination using multitarget tissue equivalent phantoms. Experiments conducted in a surrounding lossy saline tank demonstrate that simultaneous recovery of both the real and imaginary components of the electrical property distribution is possible using absolute imaging procedures over a frequency range of 300-700 MHz. Further, image reconstructions of embedded tissue-equivalent targets are found to be quantitative not only with respect to geometrical factors such as object size and location but also electrical composition. Quantitative assessments based on full-width half-height criteria reveal that errors in diameter estimates of reconstructed targets are less than 10 mm in all cases, whereas, positioning errors are less than 1 mm in single object experiments but degrade to 4-10 mm when multiple targets are present. Recovery of actual electrical properties is found to be frequency dependent for the real and imaginary components with background values being typically within 10-20% of their correct size and embedded object having similar accuracies as a percentage of the electrical contrast, although errors as high as 50% can occur. The quantitative evaluation of imaging performance has revealed potential advantages in a two-tiered receiver antenna configuration whose measured field values are more sensitive to target region changes than the typical tomographic type of approach which uses reception sites around the full target region perimeter. This measurement strategy has important implications for both the image reconstruction algorithm where there is a premium on minimizing problem size without sacrificing image quality and the hardware system design which seeks to economize on the amount of measured data required for quantitative image reconstruction while maximizing its sensitivity to target perturbations.

Algorithms↗

An active microwave imaging system for reconstruction of 2-D electrical property distributions.

The goal of this work is to develop a microwave-based imaging system for hyperthermia treatment monitoring and assessment. Toward this end, a four transmit channel and four receive channel hardware device and concomitant image reconstruction algorithm have been realized. The hardware is designed to measure electric fields (i.e., amplitude and phase) at various locations in a phantom tank with and without the presence of various heterogeneities using standard heterodyning principles. Particular attention has been paid to designing a receiver with better than 115 dB of linear dynamic range which is necessary for imaging biological tissue which often has very high conductivity, especially for tissues with high water content. A calibration procedure has been developed to compensate for signal loss due to three-dimensional radiation in the measured data, since the reconstruction process is only two-dimensional at the present time. Results are shown which demonstrate the stability and accuracy of the measurement system, the extent to which the forward computational model agrees with the measured field distribution when the electrical properties are known, and image reconstructions of electrically unknown targets of varying diameter. In the latter case, images of both the reactive and resistive component of the electrical property distribution have been recoverable. Quantitative information on object location, size, and electrical properties results when the target is approximately one-half wavelength in size. Images of smaller objects lack the same level of quantitative information, but remain qualitatively correct.

Algorithms↗

Further development and clinical application of the stereotactic operating microscope.

Implementation of a Vicom-VME image processing workstation for the frameless stereotactic operating microscope system has allowed an improved interpolation algorithm for more accurate reconstruction of three-dimensional data, the integration graphically of multimodality imaging information, an additional stereotactic graphics display outside of the microscope optics and optional three-dimensional displays through communication with a Convex mini-supercomputer. A precision-milled coupling for reproducible attachment of the spark gap bracket to the microscope has eliminated the need for that transformation calculation during each case. Clinical utility has been greatest in providing navigational guidance to small subcortical or deep lesions and in defining the extent of preoperatively planned resection of larger, infiltrating tumors. Mean accuracy in the past 17 cases has been 3.5-6.5 mm. The frameless methodology has also enabled extracranial stereotactic surgical procedures in 7 patients.

Brain Neoplasms↗