PubMed Health⌕ Search

Biomedical subjects

A Haushofer

Publications and source records attributed to A Haushofer.

22 records · Page 2Linked to original sources

Indications for the presence of antibodies cross-reactive with HTLV-I/II, but not HIV, in patients with myelodysplastic syndrome.

Serological evidence is presented for the fact that patients with the myelodysplastic syndrome exhibit a statistically significant reactivity in confirmatory assays for antibodies to human T-lymphotropic viruses types I and II (HTLV-I/II). This antibody reactivity, evident by indirect immunofluorescence and Western blot, was not confined to HTLV core antigens but extended to native and recombinant envelope glycoproteins. The effect was also observed in cases of acute myeloic leukemia, albeit to a lesser degree. It was essentially absent from patients with chronic myeloic leukemia or lymphocytic leukemias and healthy or multitransfused controls. No antibodies to human immunodeficiency viruses types 1 or 2 were detected in any of the specimens. The investigated clinical population had no known risk factor for retroviral infection other than a history of multiple platelet transfusions, and none of the specimens was seropositive for HTLV-I or HTLV-II according to recommended criteria. The cause of this cross-reactivity remains to be determined.

Antibodies, Viral↗

[Automation in the modern coagulation laboratory. Exemplified by the integration of the Microanalyser ACL 300].

We report on the organisation of our coagulation laboratory which had to meet the requirements of both, the large routine operations and those of a special laboratory for specific blood coagulation problems. A valuable support for the routine activities of our coagulation laboratory was the installation of 2 automated coagulation analysers, type ACL 300. Due to the selective (diagnosis/therapy) patient-related allotment of samples and the establishment of a final diagnosis according to a step-wise method it was possible to integrate the 2 ACL 300 analysers into our existing system and consequently to take full advantage of the savings in staff time. Moreover we report on the evaluation of the 1st ACL 300 (810) analyser and the specific characteristics of the ACL series.

Autoanalysis↗

[Clinical study comparing the effectiveness and tolerance of 2 current and one new glibenclamide formulation].

In a clinical study efficacy and tolerance of Neogluconin (2.5 mg) a new galenical form of glibenclamide were compared with a conventional preparation (Euglucon 5). Neogluconin showed an improved absorption and comparable blood sugar levels at a dosage reduced by 25%. 25 outpatients suffering from Type II diabetes in a well balanced metabolic state and previously under Euglucon therapy for at least one year were changed to the new product. After 2 months of Neogluconin therapy blood sugar profiles, HbA1, C-peptide and cholesterin levels were unchanged in comparison to values determined during the previous Euglucon treatment. This confirms that Neogluconin produces a comparable favorable blood glucose lowering effect despite a 25% reduction in dosage.

Aged↗

Comparison of a new automated kinetically determined fibrinogen assay with the 3 most used fibrinogen assays (functional, derived and nephelometric) in Austrian laboratories in several clinical populations and healthy controls.

A new automated kinetically determined fibrinogen assay was measured in plasmas of healthy subjects and three clinical cohorts (acute-phase reaction, liver cirrhosis and fibrinolytic therapy) that were expected to show normal, high and low levels of fibrinogen. The results were compared with the results of fibrinogen measurement using the derived method, the method according to Clauss and an immunological-nephelometric method. Altogether, the best correlation was achieved between the kinetic and the derived method. However, results from the derived method were generally higher than values obtained through the kinetic method. This was particularly true for high concentration levels above 400 mg/dl (patients with acute phase reaction) as well as for plasmas containing fibrin(ogen) degradation products and low concentrations of fibrinogen (below 150 mg/dl). Fibrinogen determinations in several commercial plasma pools with declared fibrinogen levels show remarkable heterogeneity when different methods were applied. To improve the discernment of fibrinogen determinations we suggest adjustment of standard preparations to international reference materials and the specification of the method used. Furthermore the attending physician is asked to cast a critical eye on fibrinogen values with regard to the used method of determination.

Acute-Phase Reaction↗