PubMed Health⌕ Search

Biomedical subjects

A Hierlemann

Publications and source records attributed to A Hierlemann.

8 recordsLinked to original sources

Nanochemical surface analyzer in CMOS technology.

We have developed an atomic force microscopy (AFM) cantilever system, fabricated using a standard CMOS process and a few post-processing steps, capable of detecting the difference between hydrophilic and hydrophobic samples for the purpose of nanochemical surface analysis. The fully integrated cantilever comprises a thermal actuator for cantilever deflection and a Wheatstone bridge to sense cantilever bending, thus obviating the need for cumbersome laser detection and external piezoelectric drives. Glass microspheres have been affixed to the cantilevers and, were either modified with a self-assembled monolayer to form hydrophobic tips, or left unmodified for hydrophilic tips. Force-distance curves have been used to measure the force between the functionalized/unfunctionalized tips and hydrophobic/hydrophilic sample surfaces. In an optimization step three different Wheatstone bridge sensors have been designed and characterized; best Wheatstone bridge sensitivity is 8.0 microV/nm with a 713 nm/mW actuator efficiency.

Journal Article↗

Smart single-chip gas sensor microsystem.

Research activity in chemical gas sensing is currently directed towards the search for highly selective (bio)chemical layer materials, and to the design of arrays consisting of different partially selective sensors that permit subsequent pattern recognition and multi-component analysis. Simultaneous use of various transduction platforms has been demonstrated, and the rapid development of integrated-circuit technology has facilitated the fabrication of planar chemical sensors and sensors based on three-dimensional microelectromechanical systems. Complementary metal-oxide silicon processes have previously been used to develop gas sensors based on metal oxides and acoustic-wave-based sensor devices. Here we combine several of these developments to fabricate a smart single-chip chemical microsensor system that incorporates three different transducers (mass-sensitive, capacitive and calorimetric), all of which rely on sensitive polymeric layers to detect airborne volatile organic compounds. Full integration of the microelectronic and micromechanical components on one chip permits control and monitoring of the sensor functions, and enables on-chip signal amplification and conditioning that notably improves the overall sensor performance. The circuitry also includes analog-to-digital converters, and an on-chip interface to transmit the data to off-chip recording units. We expect that our approach will provide a basis for the further development and optimization of gas microsystems.

Journal Article↗

Use of linear solvation energy relationships for modeling responses from polymer-coated acoustic-wave vapor sensors.

The applicability and performance of linear solvation energy relationships (LSERs) as models of responses from polymer-coated acoustic-wave vapor sensors are critically examined. Criteria for the use of these thermodynamic models with thickness-shear-mode resonator (TSMR) and surface-acoustic-wave (SAW) vapor sensors are clarified. Published partition coefficient values derived from gas-liquid chromatography (GLC) are found to be consistently lower than those obtained gravimetrically, in accordance with previous reports, suggesting that LSERs based on GLC-derived partition coefficients will not provide accurate estimates of acoustic-wave sensor responses. The development of LSER models directly from polymer-coated TSMR vapor sensor response data is demonstrated and a revised model developed from SAW vapor sensor response data, which takes account of viscoelastic changes in polymeric coating films, is presented and compared to those developed by other methods.

Chromatography, Gas↗

Search for extraterrestrial enantioenrichment by using chemical microsensors.

The use of enantioselective chemical microsensors is proposed for the search of extraterrestrial homochirality in space. The already established enantiomer-discrimination-capability of chemical sensors and the feasibility of quantitatively determining the enantiomeric composition of a target analyte are demonstrated. The benefits of applying modern microsensor technology are presented followed by some concepts and scenarios including how chemical microsensors could be used in space.

Journal Article↗

Conferring selectivity to chemical sensors via polymer side-chain selection: thermodynamics of vapor sorption by a set of polysiloxanes on thickness-shear mode resonators

Entropy of mixing is shown to be the driving interaction for the endothermic physisorption process of organic vapor partitioning into seven systematically side-chain-modified (polar, acidic, basic, polarizable side groups and groups interacting via H-bridges) polysiloxanes on thickness-shear mode resonators. Each sensor was exposed to seven analytes, selected for their diversity of functional groups. This systematic investigation of sorption yields benchmarking data on physisorption selectivity: response data and modeling reveal a direct correlation of partition coefficients with interactions between specific polymer side chains and analyte functional groups. Partition coefficients were determined for every polymer/analyte pairing over the 273-343 K range at 10 K intervals; from partition coefficient temperature dependence, overall absorption enthalpies and entropies were calculated. By subtracting the enthalpy and entropy of condensation for a given pure analyte, its mixing entropy (primarily combinatorial) and mixing enthalpy (associated with intermolecular interactions) with each polymer matrix were determined. These two crucial thermodynamic parameters determine the chemical selectivity patterns of the polymers for the analytes. Simple molecular modeling based on the polymer contact surface share of the modified side group or the introduced functional group reveals a direct correlation between the partition coefficients and the side-group variation.

Journal Article↗

Effective use of molecular recognition in gas sensing: results from acoustic wave and in situ FT-IR measurements.

To probe directly the analyte/film interactions that characterize molecular recognition in gas sensors, we recorded changes to the in situ surface vibrational spectra of specifically functionalized surface acoustic wave (SAW) devices concurrently with analyte exposure and SAW measurement of the extent of sorption. Fourier transform infrared external-reflectance spectra (FT-IR-ERS) were collected from operating 97-MHz SAW delay lines during exposure to a range of analytes as they interacted with thin-film coatings previously shown to be selective: cyclodextrins for chiral recognition, nickel camphorates for Lewis bases such as pyridine or organophosphonates, and phthalocyanines for aromatic compounds. In most cases where specific chemical interactions--metal coordination, "cage" compound inclusion, or pi-stacking--were expected, analyte dosing caused distinctive changes in the IR spectra, together with anomalously large SAW sensor responses. In contrast, control experiments involving the physisorption of the same analytes by conventional organic polymers did not cause similar changes in the IR spectra, and the SAW responses were smaller. For a given conventional polymer, the partition coefficients (or SAW sensor signals) roughly followed the analyte fraction of saturation vapor pressure. These SAW/FT-IR results support earlier conclusions derived from thickness-shear mode resonator data.

Acoustics↗

Chiral discrimination of inhalation anesthetics and methyl propionates by thickness shear mode resonators: new insights into the mechanisms of enantioselectivity by cyclodextrins.

The discrimination of the enantiomers of methyl lactate, methyl 2-chloropropionate, and the inhalation anesthetics enflurane, isoflurane, and desflurane in the gas phase has been performed using thickness shear mode resonators. The selective coating was a modified perpentylated gamma-cyclodextrin derivative dissolved in a polysiloxane matrix. A new model for the sorption of the chiral compounds into the cyclodextrin cavities and into the polymer matrix was established for the purpose of characterizing the sensor responses. This characterization included the fitting of the sensor responses (preferential and nonpreferential sorption) according to the model and extracting the characteristic parameters. In particular we attempted to explain the observed variation of the chiral discrimination factor alpha with changing analyte or cyclodextrin concentrations and search for an invariable parameter, characteristic for a certain analyte-cyclodextrin combination. The process of chiral or "molecular" recognition was thoroughly investigated.

Anesthetics, Inhalation↗

Chiral discrimination using piezoelectric and optical gas sensors.

Odour perception in humans can sometimes discriminate different enantiomers of a chiral compound, such as limonene. Chiral discrimination represents one of the greatest challenges in attempts to devise selective and sensitive gas sensors. The importance of such discrimination for pharmacology is dear, as the physiological effect of enantiomers of drugs and other biologically active molecules may differ significantly. Here we describe two different sensor systems that are capable of recognizing different enantiomers and of qualitatively monitoring the enantiomeric composition of amino-acid derivatives and lactates in the gas phase. One sensor detects changes in mass, owing to binding of the compound being analysed (the 'analyte'), by thickness shear-mode resonance; the other detects changes in the thickness of a surface layer by reflectometric interference spectroscopys. Both devices use the two enantiomers of a chiral polymeric receptor, and offer rapid on-line detection of chiral species with high selectivity.

Alanine↗