PubMed Health⌕ Search

Biomedical subjects

A Hopt

Publications and source records attributed to A Hopt.

3 recordsLinked to original sources

Early-onset ALS with long-term survival associated with spastin gene mutation.

The authors report a 73-year-old patient with a natural history of early-onset ALS for 49 years presenting with limb and bulbar amyotrophy and a pyramidal syndrome. Analysis of the locus SPG4 identified a heterozygous duplication mutation (c.304_309dupGCCTCG) within exon 1 of the spastin gene. We propose that sequence alterations of spastin may comprise a genetic risk factor in a greater spectrum of motor neuron disorders including clinical variants of ALS.

Adenosine Triphosphatases↗

Highly nonlinear photodamage in two-photon fluorescence microscopy.

Two-photon fluorescence excitation is being increasingly used in laser scan microscopy due to very low photodamage induced by this technique under normal operation. However, excitation intensity has to be kept low, because nonlinear photodamage sets in when laser power is increased above a certain threshold. We studied this kind of damage in bovine adrenal chromaffin cells, using two different indicators of damage: changes in resting [Ca(2+)] level and the degranulation reaction. In agreement with previous studies, we found that, for both criteria, damage is proportional to the integral (over space and time) of light intensity raised to a power approximately 2.5. Thus, widening the laser pulse shape at constant average intensity both in time and in focal volume is beneficial for avoiding this kind of damage. Both measures, of course, reduce the two-photon fluorescence excitation. However, loss of signal can be compensated by increasing excitation power, such that, at constant damaging potential, signals may be even larger with long pulses and large focal volumes, because the exponent of the power law of damage is higher (mu approximately 2.5) than that of the two-photon signal (mu approximately 2).

Adrenal Glands↗

Fast scanning and efficient photodetection in a simple two-photon microscope.

Two-photon laser scan microscopy carries many advantages for work on brain slices and bulk tissue. However, it has very low signal levels compared to conventional fluorescence microscopy. This is disadvantageous in fast imaging applications when photon shot noise is limiting. Working on brain slices with excitation powers of 8-10 mW at the specimen plane, the resting signal from cerebellar Purkinje cell somas loaded with 10 microM Oregon Green 488 BAPTA-1 averaged 4 detected photons/micros; axons of interneurons loaded with 200 microM of this indicator yielded about 1 photon/micros. To obtain satisfactory images at high time resolution, long pixel dwell times are required and data collection should be restricted to as few pixels as necessary. Furthermore, a large proportion of total measurement time (duty cycle) should be available for data collection. We therefore developed a method for scanning small regions of interest with line repetition rates two to four times higher than conventional ones and a duty cycle of 70%. We also compared the performance of several photodetectors and found the optimum choice to depend strongly on the photon flux during a given application. For fluxes smaller than 5 photons/micros, the photon counting avalanche photodiode shows the best signal to noise ratio. At larger fluxes, photomultipliers or intensified photodiodes are superior.

Animals↗