Electroencephalogram-based scaling of multifocal visual evoked potentials: effect on intersubject amplitude variability.

PURPOSE: The interindividual variability of the visual evoked potential (VEP) has been recognized as a problem for interpretation of clinical results. This study examines whether VEP variability can be reduced by scaling responses according to underlying electroencephalogram (EEG) activity. METHODS: A multifocal objective perimeter provided different random check patterns to each of 58 points extending out to 32 degrees nasally. A multichannel VEP was recorded (bipolar occipital cross electrodes, 7 min/eye). One hundred normal subjects (age 58.9 +/- 10.7 years) were tested. The amplitude and inter-eye asymmetry coefficient for each point of the field was calculated. VEP signals were then normalized according to underlying EEG activity recorded using Fourier transform to quantify EEG levels. High alpha-rhythm and electrocardiogram contamination were removed before scaling. RESULTS: High intersubject variability was present in the multifocal VEP, with amplitude in women on average 33% larger than in men. The variability for all left eyes was 42.2% +/- 3.9%, for right eyes 41.7% +/- 4.4% (coefficient of variability [CV]). There was a strong correlation between EEG activity and the amplitude of the VEP (left eye, r = 0.83; P < 0.001; right eye, r = 0.82; P < 0.001). When this was used to normalize VEP results, the CVs dropped to 24.6% +/- 3.1% (P < 0.0001) and 24.0% +/- 3.2% (P < 0.0001), respectively. The gender difference was effectively removed. CONCLUSIONS: Using underlying EEG amplitudes to normalize an individual's VEP substantially reduces intersubject variability, including differences between men and women. This renders the use of a normal database more reliable when applying the multifocal VEP in the clinical detection of visual field changes.

Adult↗

Multifocal pattern electroretinogram does not demonstrate localised field defects in glaucoma.

PURPOSE: To determine if a multifocal PERG could be recorded in normals, and to examine changes in the multifocal PERG in glaucoma patients. To compare the ability of multifocal PERG and multifocal VEP responses in the same individuals to identify localised field defects in glaucoma. METHODS: Using the VERIS Scientific system multifocal PERGs were recorded from 19 sites of the visual field according to pseudo-random binary m-sequence. Twenty normals and 15 glaucoma subjects were tested. Multifocal pattern VEPs were also recorded in the glaucoma cases using a cortically scaled stimulus. RESULTS: The second order kernel of the PERG shows a consistent signal. The overall PERG amplitude decreases with age in normals. In glaucoma the PERG amplitude was reduced across the field, but reductions did not correspond to the area of the scotoma. The VEP showed localised signal reductions in all 15 cases of glaucoma. CONCLUSION: A multifocal PERG can be recorded in normals. However it did not reflect localised ganglion cell losses, whereas the multifocal pattern VEP recorded to a very similar stimulus in the same individual did show losses in the scotoma area.

Adult↗

Objective VEP perimetry in glaucoma: asymmetry analysis to identify early deficits.

PURPOSE: The multifocal visual evoked potential (VEP) shows markedly symmetrical responses between the two eyes of control subjects. Patients with glaucoma and patients considered at high risk for glaucoma were examined to determine if VEP asymmetry could be identified and used for diagnosis and detection of early damage. METHODS: Multifocal pattern VEP recordings were performed using a single channel bipolar occipital electrode position and the Visual Evoked Response Imaging System (VERIS). There were 125 subjects: 24 control subjects, 70 patients with glaucoma, and 31 patients considered at high risk for glaucoma. A between-eye relative asymmetry coefficient (RAC) was determined for each of the 60 test points in the VEP field. The RAC for patients with glaucoma and patients considered at risk for glaucoma were compared with values from control subjects. Correlation between Humphrey thresholds and RAC scores was performed. RESULTS: Patients with glaucoma and patients considered at risk for glaucoma both showed significantly larger mean quadrant RAC values. When point by point analysis was performed, 69 out of 70 scotomas were identified with a cluster of at least 3 points of P < 0.05. For those considered at high risk for glaucoma, 10 out of 31 patients had abnormal areas in the VEP field. There was a strong correlation (r = 0.82) between quadrantic RAC mean values and Humphrey quadrant threshold scores in an asymmetric glaucoma subgroup. Abnormal VEP responses were identified in parts of the visual field that were still normal on perimetry. CONCLUSIONS: Asymmetry analysis correctly identifies patients with glaucomatous field loss and shows abnormalities in many patients considered at high risk for glaucoma who still have normal fields. Asymmetry analysis is able to identify objectively the extent of glaucomatous damage and may be able to detect changes before subjective field loss occurs.

Adolescent↗

Multifocal pattern VEP perimetry: analysis of sectoral waveforms.

PURPOSE: The objective detection of local visual field defects using multi-focal pattern visual evoked potentials (VEP) has recently been described. The individual waveforms show variable polarity in different parts of the visual field due to underlying cortical convolutions. Normal trace arrays were examined to determine if certain areas of similar waveform could be grouped for analysis, while minimising cancellation of data. METHOD: The VEP was assessed using multi-focal pseudo-randomly alternated pattern stimuli which were cortically scaled in size. Bipolar occipital electrodes were used for recording. Waveforms were compared for different locations within the field up to 25 degrees of eccentricity. Analysis of sectors showing similarly shaped waveforms was performed. Twelve normal subjects were studied. RESULT: Grouping waveforms by sectors of similar waveform increased the total calculated upper hemifield amplitude by 60%, compared with simple summations of responses for the whole hemifield. The inferior hemifield showed more consistent waveforms throughout, with the amplitude only increasing by 11% with sectoral summation. Intra-subject variability (10.6%) is less for sectors than for individual points (17.3%). Inter-subject amplitude differences are high, calculated at 56% for individual points and 45% for sectors. CONCLUSIONS: Due to differences in waveform as a result of underlying cortical anatomy, individual VEP responses from multifocal recordings should be grouped as sectors along the vertical meridian and above and below the horizontal, rather than by hemifields or quadrants. This finding is significant if one is considering within-field grouping strategies similar to the glaucoma hemifield test used in conventional perimetry, or reporting derived overall VEP amplitudes and latencies from a multifocal recording. Large amplitude variations between individuals and small signals from horizontal and upper field seen in single channel recording, still limit the application of this technique as a form of objective perimetry.

Evoked Potentials, Visual↗

Early magnocellular loss in glaucoma demonstrated using the pseudorandomly stimulated flash visual evoked potential.

PURPOSE: Components of the pseudorandomly stimulated flash visual evoked potential (VEP) have now been identified that appear to arise predominantly from each of the magnocellular (M-cell) and parvocellular (P-cell) systems. In this study, the relative damage to magnocellular and parvocellular systems at different stages of glaucoma using pseudorandomly stimulated flash VEP was investigated. METHODS: Pseudorandomly stimulated flash VEP was recorded in 15 normal eyes and 28 eyes with different stages of glaucoma using the VERIS-3 recording system (Electro-Diagnostic Imaging, San Francisco, CA). Two levels of luminance contrast of the stimulus (32% and 99%) were tested. The first slice of the second-order kernel from only the central (8 degrees) stimulated area was extracted for analysis. RESULTS: Data recorded from normal eyes demonstrated early saturation of the response/contrast function of the first slice of the second-order kernel. The ratio of the VEP amplitude recorded at 32% and 99% of the luminance contrast was close to unity. In eyes with early glaucoma, although the amplitude of the responses to both low- and high-contrast stimulation decreased, the relative reduction of the low-contrast VEP (M-cell) was more prominent. However, the amplitude of the high-contrast response (P-cell) declined more rapidly later in the disease. CONCLUSION: These results are consistent with relatively earlier damage of the magnocellular pathway in glaucoma.

Adult↗

Electrode position and the multi-focal visual-evoked potential: role in objective visual field assessment.

PURPOSE/METHODS: To improve the performance of visual-evoked potentials (VEP) in the assessment of the human visual field, the multi-focal cortically scaled pattern VEP was recorded up to 250 of eccentricity in normal subjects. Monopolar and varying bipolar electrode positions were used. RESULTS: The monopolar response was strongly biased towards the lower hemifield. Bipolar leads straddling the inion (2 cm above and below) achieved approximately equal signals from the upper and lower visual field. Division into sectors of similar wave-form augments the analysis compared with summed full-field responses. CONCLUSION: With this technique, the multi-focal VEP can be used to objectively assess the visual field.

Cerebral Cortex↗

Multifocal topographic visual evoked potential: improving objective detection of local visual field defects.

PURPOSE: To investigate the relationships between the pattern stimulation of different parts of the visual field (up to 25 degrees of eccentricity), the electrode position, and the cortical response to improve objective detection of local visual field defects. METHODS: The human visual evoked potential (VEP) was assessed using multifocal pseudorandomly alternated pattern stimuli that were cortically scaled in size. Monopolar and bipolar electrode positions were used. The visual field was investigated up to 26 degrees of eccentricity. Twelve normal subjects and seven subjects with visual field defects of different nature were studied. RESULTS: Although the monopolar response is heavily biased toward the lower hemifield, bipolar leads overlying the active occipital cortex (straddling the inion) demonstrate good signals from all areas of the visual field tested. The amplitude is almost equal for the averaged upper and lower hemifields, but the polarity is opposite, causing partial cancellation of the full-field VEP. The degree of cancellation depends mainly on latency differences between the vertical hemifields. The bipolar VEP corresponded well with Humphrey visual field defects, and it showed a loss of signal in the scotoma area. CONCLUSIONS: The multifocal VEP demonstrates good correspondence with the topography of the visual field. Recording with occipital bipolar electrode placement is superior to standard monopolar recording. To avoid a full-field cancellation effect, a separate evaluation of upper and lower hemifields should be used for the best assessment of retinocortical pathways. This technique represents a significant step toward the possible application of the multifocal VEP to objective detection of local defects in the visual field.

Adult↗