Carpentier-Edwards standard and supra-annular porcine bioprostheses: 10 year comparison of structural valve deterioration.

From 1975 to 1986 the Carpentier-Edwards standard (CE-S) and supra-annular (CE-SAV) porcine bioprostheses were implanted in 1213 and 1000 patients, respectively. The mean age of the standard group was 57.6 years (range 8 to 85 years) while in the supra-annular group it was 60.7 years (range 13 to 85 years). The freedom from structural valve deterioration (SVD) at 10 years for the entire patient population was 79.4% +/- 3.1% with CE-SAV and 76.1% +/- 1.6% with CE-S (p < 0.05). The overall freedom from SVD for those patients undergoing mitral valve replacement (MVR) was 74.5% +/- 4.6% for CE-SAV and 68.7% +/- 2.8% for CE-S (p = NS), while for those undergoing aortic valve replacement (AVR) it was 86.5% +/- 4.3% for CE-SAV and 84.1% +/- 2.0% for CE-S (p = NS). In those patients under 35 years of age undergoing MVR, the freedom from SVD for CE-SAV and CE-S was 94.4% +/- 5.4% and 62.9% +/- 8.6%, respectively (p < 0.05 at 8 years); for those aged 36-50 years, it was 75.6% +/- 7.4% and 61.7% +/- 6.0%; for those aged 51-65 years, it was 76.2% +/- 7.4% and 69.6% +/- 4.2%; for those over 65 years, it was 74.1% +/- 7.1% and 82.2% +/- 5.2%; for those aged 65-69 years, it was 70.2% +/- 8.7% and 63.7% +/- 8.1%; and for those over 70 years of age, it was 79.2% +/- 8.7% and 95.3% +/- 3.2%, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Structural valve deterioration in elderly patient populations with the Carpentier-Edwards standard and supra-annular porcine bioprostheses: a comparative study.

From 1975 to 1989, over 1400 patients in the elderly population and over 1700 patients under 65 years of age received the Carpentier-Edwards standard (CE-Standard) and supra-annular porcine (CE-SAV) bioprotheses. The mean ages of the patients receiving the two protheses within the three subgroups of the elderly population-65-69 years, 70-79 years, and 80 years and over-were relatively similar. There was no statistically significant difference in the performance of the prostheses regarding structural valve deterioration (SVD) at seven years. The freedom from SVD for aortic valve replacement in the 65-69 years group at seven years was 98.7% +/- 1.3% for the CE-Standard and 98.7% +/- 1.0% for the CE-SAV, for both the 70-79 years group and the 80 years and over group the figure was 100% for both prostheses (p = NS). The freedom from SVD after mitral valve replacement in the 65-69 years group at seven years was 90.0% +/- 4.3% for the CE-Standard and 84.8% +/- 7.5% for the CE-SAV, for the 70-79 years group it was 95.3% +/- 3.2% and 95.5% +/- 3.6% respectively and for the 80 years and over group the figure was 100% for both prostheses (p = NS within groups). The long term freedom from SVD after aortic valve replacement was 98.4% +/- 3% at 15 years for the CE-Standard in the 65-69 years group, 94.9% +/- 5% at 13 years for the 70-79 years group and 100% at 13 years for the 80 years and over group.(ABSTRACT TRUNCATED AT 250 WORDS)

Age Distribution↗

The Carpentier-Edwards standard porcine bioprosthesis: clinical performance to 15 years.

The Carpentier-Edwards standard porcine bioprosthesis was implanted in 1,195 patients in 1,213 operative procedures between 1975 and 1987, with the majority of implants performed prior to 1982 at the University of British Columbia. The mean age of the patient population was 57.2 years (range 8 to 85 years). The mean follow-up was 7.4 years per patient. The freedom from the combination of thromboembolism and antithromboembolic therapy-related hemorrhage at 15 years was 79.5% for aortic valve replacement (AVR), 72% for mitral valve replacement (MVR), and 84% for multiple valve replacement (MR) (p less than 0.05, AVR greater than MR greater than MVR). The freedom from structural valve deterioration at 15 years was 71% for AVR, 41% for MVR, and 41% for MR (14 years) (p less than 0.05, AVR greater than MVR greater than MR). The freedom from nonstructural dysfunction and prosthetic valve endocarditis did not distinguish the valve positions (p = NS). The freedom from valve-related mortality from all causes including reoperation was 92% for AVR, 78% for MVR, and 77% for MR at 15 years (p less than 0.05, AVR greater than MVR greater than MR). The freedom from residual morbidity was not significantly different between valve positions (p = NS). The freedom from treatment failure (valve-related mortality and residual morbidity) at 15 years was 87% for AVR, 72% for MVR, and 75% for MR (p less than 0.05, AVR greater than MR greater than MVR). The freedom from all complications at 14 years was 50% for AVR, 25% for MVR, and 27% for MR (p less than 0.05, AVR greater than MR greater than MVR).(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

The Carpentier-Edwards supra-annular porcine bioprosthesis: clinical performance to 8 years of a new generation porcine bioprosthesis.

The Carpentier-Edwards supra-annular porcine bioprosthesis has been utilized at the University of British Columbia since its introduction in 1982. The prosthesis was designed to improve hemodynamics with the supra-annular configuration and to reduce tissue failure with low-pressure glutaraldehyde preservation of the porcine aortic tissue. The prosthesis was inserted in 1,956 patients with 2,129 prostheses between 1982 and 1989. The mean age of the patient population was 62.7 years (range 13 to 87 years). The mean follow-up was 3.7 years per patient. The freedom from thromboembolism and antithromboembolic therapy-related hemorrhage at 8 years was 92% for aortic valve replacement (AVR), 83% for mitral valve replacement (MVR), and 92% for multiple valve replacement (MR) (p less than 0.05, AVR greater than MR greater than MVR). The freedom from structural valve deterioration was 86% for AVR, 73% for MVR, and 96% for MR at 8 years (p less than 0.05, AVR greater than MR greater than MVR). The freedom from nonstructural valve dysfunction and prosthetic valve endocarditis was not different between positions (p = NS). The freedom from valve-related mortality at 8 years was 98% for AVR, 94% for MVR, and 98% for MR (p less than 0.05, AVR greater than MR greater than MVR). The freedom from residual morbidity was not different at 8 years (p = NS). The freedom from treatment failure (valve-related mortality and residual morbidity) was 96% for AVR, 89% for MVR, and 94% for MR (p less than 0.05, AVR greater than MVR greater than MR).(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Pregnancy and childbearing in a population with biologic valvular prostheses.

Long-term performance of biological prostheses and course of pregnancy, labor, and delivery were evaluated in women less than 35 years of age. Between 1975 and 1987, 87 female patients received a porcine (n = 86) or pericardial valve (n = 1); the mean patient age was 26.8 years, with a range of 8 to 35 years. A total of 17 of these patients experienced 37 pregnancies. A total of 25 babies were delivered, of which 19 were babies of normal birth weight born at term and six were born prematurely (two of these were stillborn). There were six spontaneous abortions and five therapeutic abortions. The mean time from primary operation to first delivery was 29 months. Of the 17 pregnant patients, 14 were in normal sinus rhythm and three were in atrial fibrillation. One of those in fibrillation had a therapeutic abortion while receiving warfarin therapy, and another was successfully delivered of her neonate after 7 months of warfarin therapy. The remaining 15 patients were treated through 35 pregnancies without anticoagulants or antiplatelet agents. Of the total population of 87 patients, 32 (36.8%) were treated for valve-related complications. Structural valve deterioration occurred in eight patients (47.1%) of the pregnancy group and 10 patients (14.3%) of the nonpregnancy group (p less than 0.05). The freedom from structural valve deterioration at 10 years was 23.3% +/- 14% for the pregnancy group and 74.2% +/- 8.5% for the nonpregnancy group (p less than 0.05, age as a determinant, p not significant). There were eight valve-related deaths (1.5%/patient-year). Reoperation was performed in 59% of the pregnancy group and 19% of the nonpregnancy group, primarily for structural valve deterioration manifested as valvular obstruction from aggressive calcification (p less than 0.05). The freedom from reoperation at 10 years parallels freedom from structural valve deterioration (20.3% +/- 12.4% and 64.3 +/- 9.1% for the pregnancy and nonpregnancy groups, respectively, with p less than 0.05; with age added as a determinant, p not significant). The overall reoperative mortality was 8.7% (two patients). The biologic prostheses afforded successful pregnancy without fetal wastage or congenital anomalies and without significant maternal morbidity or mortality.

Adult↗

Age as a determinant for selection of porcine bioprostheses for cardiac valve replacement: experience with Carpentier-Edwards standard bioprosthesis.

Almost exclusive use of Carpentier-Edwards porcine bioprostheses for cardiac valve replacement in 1194 patients between 1975 and 1987 at the authors' institutions has afforded the opportunity for a more scientific basis for prosthesis selection for subsets of patients, with regard to age and valve-related complications. The present study, performed according to previously established guidelines, investigated the influence of patient age and valve position as determinants of durability of 1315 porcine implants in terms of the following valve-related complications: structural valve deterioration, nonstructural dysfunction, thromboembolism, antithromboembolic therapy-related hemorrhage and prosthetic valve endocarditis. Age groups were as follows: 35 years and younger, 36 to 50 years, 51 to 65 years, and 66 years or older. Thromboembolism was found to be less common in the younger age groups, and significantly less common in patients following aortic compared to mitral valve replacement. The age group assessment for antithromboembolic therapy-related hemorrhage, nonstructural dysfunction and prosthetic valve endocarditis revealed no difference between positions or age groups. Patient age was found to be the major predictor of, and inversely related to, structural valve deterioration. In addition, porcine bioprostheses in the aortic position were shown to have durability superior to that of similar valves in the mitral position. Structural valve deterioration has very little influence on valve-related mortality and residual morbidity. This study thus supports the implantation of porcine bioprostheses in somewhat younger patients than would be advisable for mitral prostheses. The authors now recommend the selective implantation of porcine bioprostheses in the aortic position in patients over 65 years of age, and in the mitral position in patients over 70 years of age.

Adolescent↗

Aortic dissection: current expectations and treatment. Experience with 258 patients over 20 years.

Aortic dissection, the most common acute disease of the thoracic aorta, is associated with high mortality and morbidity. The authors reviewed their experience over the last 20 years with 258 patients who had aortic dissection (259 dissections). The diagnosis was made at autopsy in 69 (27%) patients (59 type A, 10 type B). Of the remainder, 97 patients had type A dissection (78 acute, 19 chronic) and 93 had type B dissection (56 acute, 37 chronic). The sudden onset of severe, unremitting chest pain associated with hyper- or hypotension or a history of hypertension are suggestive of acute aortic dissection. The diagnosis should be followed by prompt investigation and treatment. The 30-day survival rate for patients with type A dissection who underwent surgical treatment was 62%; survival rates for patients with type B dissection, acute and chronic, were 70% and 86% respectively with pharmacotherapy and 66% and 91% with surgery. The authors stress the importance of early, accurate diagnosis and immediate surgical treatment for all patients who have type A dissection and complicated or unresponsive (carefully monitored pharmacologic control of blood pressure) type B dissection.

Adult↗

The Carpentier-Edwards standard porcine bioprosthesis. A first-generation tissue valve with excellent long-term clinical performance.

The Carpentier-Edwards standard porcine bioprosthesis was implanted in 1190 patients (1201 operations, 1303 valves) between January 1975 and June 1986; most implants were before 1982. The mean age of the patients was 57.2 years (range 8 to 85 years). The early mortality was 7.6% (aortic valve replacement 5.1%, mitral valve replacement 8.8%, and multiple valve replacement 15.3%). Late mortality was 3.9% per patient-year (aortic valve replacement 3.6%, mitral valve replacement 4.2%, and multiple valve replacement 3.8%). The total cumulative follow-up period was 6737 years. Thromboembolism was 1.5% per patient-year (fatal 0.4% per patient-year) (minor 0.6%, major 0.9%); antithromboembolic therapy-related hemorrhage was 0.5% (fatal 0.1%); prosthetic valve endocarditis was 0.6% (fatal 0.2%); nonstructural dysfunction was 0.5% (fatal 0.2%); and structural valve deterioration and/or primary tissue failure was 1.5% per patient-year (fatal, 0.2% per patient-year). Thromboembolism and structural valve deterioration were the significant complications, structural valve deterioration occurring primarily between the sixth and 10th year of evaluation. The overall patient survival was 65.0% for aortic valve replacement and 54.8% for mitral valve replacement (p less than 0.05) at 10 years. The patients were classified as 92.9% New York Heart Association functional classes III and IV preoperatively and 92.3% classes I and II postoperatively. Freedom at 10 years from thromboembolism was 84.3% for aortic valve replacement and 76.5% for mitral valve replacement (p = 0.05); structural valve deterioration was 78.6% for aortic valve replacement and 71.6% for mitral valve replacement (p less than 0.05); reoperation was 74.4% for aortic valve replacement and 67.1% for mitral valve replacement (p less than 0.05). Freedom from all valve-related complications at 10 years was 58.9% for aortic valve replacement and 46.8% for mitral valve replacement (p less than 0.05); valve-related mortality was 89.5% for aortic valve replacement and 82.6% for mitral valve replacement (p = not significant); mortality and reoperation was 58.9% for aortic valve replacement and 46.8% for mitral valve replacement (p less than 0.05); mortality and residual morbidity (treatment failure) was 87.2% for aortic valve replacement and 75.1% for mitral valve replacement (p = not significant); mortality, residual morbidity, and reoperation were 66.3% for aortic valve replacement and 54.9% for mitral valve replacement (p less than 0.05). The standard Carpentier-Edwards porcine bioprosthesis has provided satisfactory clinical performance and has afforded patients excellent quality of life.

Adolescent↗

Cardiac valve replacement in the elderly: clinical performance of biological prostheses.

From 1975 to 1987, 1,127 elderly patients underwent 1,223 valve replacements with the Carpentier-Edwards standard or supraannular porcine bioprostheses in 1,147 operations. Of the total patient population seen during these years, 33.5% receiving a standard porcine bioprosthesis and 48.6% receiving a supraannular bioprosthesis were 65 years of age or older. Of this elderly patient population, 465 patients were between 65 and 69 years old; 618 patients, 70 and 79 years old; and 52 patients, 80 years old and older. Aortic valve replacement was performed in 635 patients, mitral valve replacement in 417 patients, tricuspid valve replacement in 2 patients, and multiple-valve replacement in 80 patients. The cumulative follow-up was 3,957 patient-years. Early mortality was 9.5%: 7.3% for the 65- to 69-year-old group, 10.7% for the 70- to 79-year-old group, and 15.4% for the group 80 years old and older. Late mortality was 5.5% per patient-year: 4.2% per patient-year for the 65- to 69-year-old group, 6.3% per patient-year for the 70- to 79-year-old group, and 14.1% per patient-year for the group 80 years old and older. Valve-related causes contributed to 7 early deaths and 33 late deaths. The overall patient survival, including operative deaths, was 70.7% +/- 1.6% at 5 years and 47.8% +/- 3.7% at 10 and 12 years. The freedom from all valve-related complications was 52.1% +/- 6.1% at 10 and 12 years. The overall rate of valve-related complications was 5.0% per patient-year (fatal complications, 1.13% per patient-year). The overall rate of thromboembolism was 2.3% per patient-year and the freedom from thromboembolism, 69.6% +/- 5.2% at 10 and 12 years. The freedom from structural valve deterioration was 80.8% +/- 8.1% at 10 and 12 years: 71.7% +/- 11.0% at 10 and 12 years for the 65- to 69-year-old group, 97.9% +/- 1.2% at 10 years for the 70- to 79-year-old group, and 100% at 12 years for the group 80 years old and older. At 10 and 12 years, the freedom from valve-related death was 83.7% +/- 4.3% and the freedom from reoperation, 73.3% +/- 8.6%. The freedom from valve-related death, residual morbidity from thromboembolism and anticoagulant-related hemorrhage, and reoperation was 61.7% +/- 7.0% at 10 and 12 years. The clinical performance of porcine bioprostheses in the elderly patient population has been excellent. The early mortality increases in patients 70 years old or older.(ABSTRACT TRUNCATED AT 400 WORDS)

Age Factors↗

Aortic dissection. A six year experience with 117 patients.

Acute aortic dissection is a medical emergency that demands immediate recognition and early precise angiographic diagnosis. One hundred seventeen patients were found to have aortic dissection between 1980 and 1986. Clinical presentation is of importance since hypertension favors the presence of type B dissection, whereas normotension or hypotension is usually indicative of a type A lesion. Supportive treatment should allow stabilization for diagnosis by angiography or computerized tomography in order to proceed with early surgical repair of all type A dissections. Management of the acute type B patient should initially be medical, but immediate surgical treatment should be carried out if there is failure to control the hypertension, continued pain, expansion or rupture of the aneurysm (including appearance of a pleural collection), development of a neurologic deficit, or evidence of compromise of a major infradiaphragmatic aortic branch. Any delay in surgical treatment once an indicative complication is identified will have an early adverse effect on prognosis. By applying these guidelines, an overall 65 to 75 percent hospital survival rate should be achieved.

Acute Disease↗

Carpentier-Edwards standard porcine bioprosthesis: primary tissue failure (structural valve deterioration) by age groups.

Primary tissue failure (structural valve deterioration) has been documented as the most prominent complication of porcine bioprostheses. The influence of age on primary tissue failure has received limited consideration. From 1975 to 1986, 1,301 Carpentier-Edwards standard porcine bioprostheses were implanted in 1,183 patients in 1,201 operations. Of the total number of prostheses, 97.7% were implanted prior to 1983. The mean follow-up was 5.6 years and was 97.5% complete. Primary tissue failure was identified in 96 patients (98 operations) at reoperation (95) or autopsy (3). One hundred four (104) prostheses were involved. Thirty-one failed after aortic valve replacement (AVR), 49 after mitral valve replacement (MVR), and 24 after multiple-valve replacement (18 patients). There were 47 male and 49 female patients. The mean age at implantation was 47 years (range, 8 to 72 years). The mean implantation time was 74.0 months. The freedom from primary tissue failure at 10 years is 77.0 +/- 2.9% overall; for AVR, 83.1 +/- 3.7%; for MVR, 72.1 +/- 4.9%; and for multiple-valve replacement, 65.5 +/- 7.8%. The freedom from deterioration for patients less than 20 years of age is significantly less than that for other age groups. The freedom from deterioration increased by decades; the greatest freedom was noted in patients 70 to 80 years old and 80 years old or older. The freedom from deterioration at 10 years for patients less than 30 years of age is 26.8 +/- 17.2%; 30 to 59 years, 77.4 +/- 3.0%; and 60 years and older, 83.1 +/- 4.2%.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

The Carpentier-Edwards supra-annular porcine bioprosthesis: new generation low pressure glutaraldehyde fixed prosthesis.

The Carpentier-Edwards supra-annular porcine bioprosthesis was implanted in 1,576 operations (1,536 patients with 1,704 valves) between 1981 and 1987. The mean age of the patients was 61.9 years (range 13 to 87 years). During the years 1981 and 1987, approximately 90% of the total valvular surgery population received the prosthesis. The early mortality was 7.0% (included patients with concomitant procedures including coronary artery bypass and ascending aortic aneurysm resection). Late mortality was 4.0% per patient-year. The total cumulative follow-up was 4,237 years. Thromboembolism (TE) was 2.4% per patient-year (fatal 0.4% per patient-year) (minor 1.2%; major 1.3%); antithromboembolic therapy-related hemorrhage (ATH) 0.5% (fatal 0.07%); prosthetic valve endocarditis (PVE) 0.5% (fatal 0.2%); periprosthetic leak (PPL) 0.3% (fatal 0%); clinical valve dysfunction (CVD) 0.3% (fatal 0.02%); and structural valve deterioration/primary tissue failure (SVD) 0.2%/patient-year (fatal 0%). Thromboembolism and structural valve deterioration were the significant complications, SVD occurring primarily between the fourth and fifth year of evaluation. The overall patient survival was 77.1% +/- 1.4% at five years. The patients were classified as 89.6% NYHA functional Class III and IV preoperatively and 96.1% Class I and II postoperatively. The freedom at five years from TE was 90.6% +/- 1.0%; SVD 98.9% +/- 0.5%; and reoperation 95.9% +/- 0.9%. Freedom from all valve-related complications at five years was 84.1% +/- 1.3%; valve-related mortality 96.8% +/- 0.7%; mortality and reoperation (valve failure) 92.9% +/- 1.1%; mortality and residual morbidity (treatment failure) 93.7% +/- 0.9%; and mortality, residual morbidity, and reoperation (valve failure and dysfunction) 90.0% +/- 1.2%. There were 28 valve-related deaths of a total 280 deaths (early 4, late 24) (TE 17; ATH 3; CVD 1; PVE 7; PPL 0; and SVD 0). Valve-related reoperations were performed in 32 patients (TE 2; CVD 4; PVE 7; PPL 11; and SVD 8). The supra-annular Carpentier-Edwards porcine bioprosthesis has provided very satisfactory clinical performance and afforded patients an excellent quality of life. The long-term durability of this low pressure glutaraldehyde fixed prosthesis will be determined by observation over the next five to seven years.

Adolescent↗

The Carpentier-Edwards standard porcine bioprosthesis: long-term evaluation of the high pressure glutaraldehyde fixed prosthesis.

The Carpentier-Edwards standard porcine bioprosthesis was implanted in 1,000 operations (988 patients with 1,092 valves) between 1975 and 1981. The mean age of the patients was 56.8 years (range 8 to 85 years). During the years 1975 and 1981, approximately 97% of the total valvular surgery population received the prosthesis. The early mortality was 7.8% (including patients with concomitant procedures including coronary artery bypass and ascending aortic aneurysm resection). Late mortality was 3.8% per patient-year. The total cumulative follow-up was 5,937 years. Thromboembolism (TE) was 1.3% per patient-year (fatal 0.4%/patient-year) (minor 0.4%; major 0.9%); antithromboembolic therapy-related hemorrhage (ATH) 0.5% (fatal 0.1%); prosthetic valve endocarditis (PVE) 0.5% (fatal 0.2%); periprosthetic leak (PPL) 0.4% (fatal 0.2%); clinical valve dysfunction (CVD) 0.2% (fatal 0.02%); and structural valve deterioration (SVD)/primary tissue failure 1.6% per patient-year (fatal 0.2%/pt-yr). Thromboembolism and SVD occurring primarily between the sixth and tenth year of evaluation, were the significant complications. The overall patient survival was 60.5% +/- 2.4% at 10 years. The patients were classified as 93.5% NYHA functional Class III and IV, preoperatively and 93.1% Class I and II, postoperatively. The freedom at 10 years from TE was 82.9% +/- 2.7%; SVD 76.9% +/- 2.9%; and reoperation 70.8% +/- 3.1%. Freedom from all valve-related complications at 10 years was 54.3% +/- 3.1%; valve-related mortality 86.4% +/- 2.3%; mortality and reoperation (valve failure) 64.0% +/- 3.2%; mortality and residual morbidity (treatment failure) 82.3% +/- 2.6%; and mortality, residual morbidity, and reoperation (valve failure and dysfunction) 60.6% +/- 3.2%. There were 61 valve-related deaths of a total 352 deaths (early 7, late 54) (TE 21; ATH 7; CVD 1; PVE 12; PPL 9; and SVD 11). Valve-related reoperations were performed in 128 patients (TE 3; CVD 4; PVE 14; PPL 17; and SVD 90). The standard Carpentier-Edwards porcine bioprosthesis has provided very satisfactory clinical performance and afforded patients excellent quality of life. Primary tissue failure is the significant long-term complication.

Adolescent↗

The Carpentier-Edwards supraannular porcine bioprosthesis. A new generation tissue valve with excellent intermediate clinical performance.

The Carpentier-Edwards supraannular porcine bioprosthesis, an investigational valve, was implanted in 1167 patients (1174 operations, 1274 valves) between November 1981 and December 1985 (age range 13 to 85 years, mean 61 years). The early mortality rate was 7.2% (with concomitant procedures 10.9%, without 4.8%; with previous operation 10.5%, without 6.6%). The late mortality rate was 4.5% per patient-year (aortic valve replacement, 4.0%; mitral valve replacement, 4.8%; multiple valve replacement, 5.6%). Total cumulative follow-up was 2272.3 years. The prevalence of thromboembolism was 2.6% per patient-year (fatal 0.4% per patient-year, major 1.4%, minor 1.2%); hemorrhage related to antithromboembolic therapy, 0.7% (fatal 0.1%); prosthetic valve endocarditis, 0.4% (fatal 0.2%); periprosthetic leak, 0.4% (fatal 0%); structural valve deterioration (primary tissue failure/structural failure), 0.1% per patient-year; and clinical valve dysfunction, 0.4%. The reoperation rate was 0.8% per patient-year (thromboembolism, 0.1%; clinical valve dysfunction, 0.1%; prosthetic valve endocarditis, 0.1%; periprosthetic leak, 0.4%; structural valve deterioration, 0.1%). Thromboembolism occurred throughout the observation period but with decreasing frequency, hemorrhage throughout the period in no predictable fashion, prosthetic valve endocarditis within 2 years, periprosthetic leak within 2 years, and structural valve deterioration occurred during the fourth year of assessment. The overall survival rate was 79.8% +/- 1.7% (4 years). Freedom (at 4 years) from thromboembolism was 92.2% +/- 1.2%; from structural valve deterioration, 98.8% +/- 0.8%; and from reoperation, 95.8% +/- 1.3%. Freedom from all complications (4 years) was 85.9% +/- 1.7%; from complication mortality, 98.4% +/- 0.4%; and from valve failure (mortality and reoperation), 94.3% +/- 1.3%. This investigational Carpentier-Edwards supraannular porcine bioprosthetic valve has provided excellent clinical performance and remains our overall prosthesis of choice.

Aged↗

Carpentier-Edwards supra-annular porcine bioprosthesis. Clinical experience and implantation characteristics.

The investigational Carpentier-Edwards supra-annular valve was implanted in 592 patients from November, 1981, to February, 1984 (aortic valve replacement in 286, mitral valve replacement in 259, and multiple valve replacement in 47, for a total of 638 prostheses). A previous cardiac operation had been performed in 77 patients (13%). Concomitant procedures were performed in 202 patients (34.1%), including coronary artery bypass in 163 patients. The patient evaluation was 98.6% complete. The early mortality was 7.4% (44 patients) and the late mortality was 6.2% per patient-year (41 patients). The valve-related causes of late mortality were thromboembolism (five), anticoagulant-related hemorrhage (one), and prosthetic valve endocarditis (one). The overall patient survival, including operative death, was 85% at 2 years. The linearized occurrence rate for valve-related complications was 5.6% per patient-year (37 events)--thromboembolism 2.7% per patient-year (18) anticoagulant-related hemorrhage 1.2% (eight), prosthetic valve endocarditis 0.8% (five), and periprosthetic leak 0.9% per patient-year (six). There were no cases of primary tissue failure or structural failure. At 2 years, the freedom from valve-related complications was 86.9%, from valve-related mortality, 98.7%, and from valve-related mortality and reoperation, 97.7%. This valve is fixed in glutaraldehyde at low pressure and is designed to improve durability. It has provided a low incidence of valve-related complications without structural failure. The structural design of the prosthesis does not always conform to the anatomy of bicuspid aortic valves.

Bioprosthesis↗

Coronary artery bypass in patients over 65 years of age.

At the Vancouver General Hospital 235 consecutive patients (172 men, 63 women) aged 65 years or older underwent aortocoronary bypass grafting between January 1974 and December 1979; 168 were 65 to 69 years of age and 67 were 70 years or older. Concomitant cardiac procedures were carried out in 65 (valve surgery in 53, resection of ventricular aneurysm in 10, repair of ventricular septal defect in 1, excision of left atrial tumour in 1). A mean of 2.6 vessels per patient were grafted. Early mortality was 7.7%. For patients who underwent bypass grafting alone, the mortality for those 65 to 69 years was 5.1% and for those 70 years or older it was 5.9%. For patients who underwent bypass grafting and a concomitant procedure, the mortality for those 65 to 69 years of age was 3.1% and for those 70 years or older 24.2%. At follow-up (mean 30 months) there were 23 late deaths. The 5-year survival (life-table method) for the whole group was 77% including early deaths and 83% excluding early deaths. Late survival in those aged 70 years or older was similar to that in patients aged 65 to 69 years. Improvement in function was good; 92% of patients were in New York Heart Association functional class I or II at follow-up, where 94% had been in class III or IV before operation. Acceptable operative mortality with good long-term survival and lessening of symptoms support the use of aortocoronary bypass grafting in patients over 65 years of age. Complex procedures in those 70 years of age or older carry a high risk.

Age Factors↗