Interpretation and quantification of immunostains.

Despite the fact that immunohistochemistry is widely used in routine diagnostic work and is a very common part of scientific reports in pathology and cytology, its standardization still lags behind. Interpretation of immunostains should be based on microanatomic distribution of the staining, proportion of positively stained cells, staining intensity, if relevant, and cutoff levels. These parameters should be shown to be reasonably reproducible and should be clearly defined in publications. Uniformity in the setting of thresholds could probably benefit from interlaboratory control materials containing defined amounts of the target antigen. Reliable and precise quantitative immunohistochemistry requires the use of control materials containing defined amounts of the target antigen and processed alongside the specimen combined with automated computer-assisted microspectrophotometry. Application of these suggestions is hoped to improve standardization and to facilitate communication in the field of immunohistochemistry.

Humans↗

Study of interlaboratory reliability and reproducibility of estrogen and progesterone receptor assays in Europe. Documentation of poor reliability and identification of insufficient microwave antigen retrieval time as a major contributory element of unreliable assays.

Immunohistochemical assays for estrogen receptors (ERs) and progesterone receptors (PRs) have not been surveyed for technical validity. In the present study, the reliability of the immunohistochemical assay for ER and PR was evaluated using data from 105 laboratories participating in external quality assessment (EQA) during a 2-year period. Technical variables associated with reliable immunostaining were analyzed. The efficiency of the antigen retrieval step was identified as the single most important contributory factor influencing the overall reproducibility of the assays. Reliable assays were found in 24 (36%) of 66 laboratories participating in continual EQA, including the majority of centers known to have clinically validated results. Inadequate assay sensitivity, with subsequent weak staining, was the main cause of poor and variable results by laboratories using microwave antigen retrieval; too short a heating time was identified as the principal contributory factor. Extension of the heating time resulted in significant improvement regardless of all other variables in the immunohistochemical protocol. Continual participation in EQA is an effective means for identifying and ameliorating variables that influence the reliability of immunohistochemical assays for predictive markers, thereby assisting in technical validation and standardization.

Antigens↗

Immunohistochemical demonstration of oestrogen and progesterone receptors: correlation of standards achieved on in house tumours with that achieved on external quality assessment material in over 150 laboratories from 26 countries.

AIMS: To investigate the sensitivity of immunohistochemical (IHC) assays for oestrogen receptors (ER) and progesterone receptors (PR) achieved by laboratories on breast tumours fixed and processed in their own department, and to compare this with the degree of sensitivity they achieve on tumours circulated as part of an external quality assessment (EQA) programme. METHODS: On 10 occasions between April 1994 and June 1998, histological sections from breast cancers showing various degrees of expression of ER and PR were circulated for IHC staining to laboratories participating in the UK national external quality assessment scheme for immunocytochemistry (UK NEQAS-ICC). The staining of these tumours, in addition to that of tumours fixed and processed in the participants own laboratories (in house tumours), was assessed by a panel of four assessors, using the established UK NEQAS-ICC scoring system. For a selected assessment run, the degree of expression of participants in house tumours was evaluated by means of the semiquantitative quick score method. RESULTS: Although the scores awarded for the staining of in house tumours were generally higher than those awarded for the staining of UK NEQAS tumours, there was also a significant positive correlation between the two sets of scores. Using the quick score method of evaluation for one of the assessment runs, 47% of in house tumours were classified as having a high degree of ER expression. Of the remaining cases, a significant proportion initially classified as having only low or medium expression of ER were found to have higher expression when stained by the organising laboratory. The UK NEQAS-ICC centre's routine assay for hormonal receptors was found to be 90-100% efficient in achieving optimal demonstration of breast tumours from over 150 different laboratories. CONCLUSIONS: The significant positive correlation between the results obtained on the UK NEQAS tumours and the in house tumours provides evidence for the view that results achieved on EQA material are accurate indicators of in house laboratory performance. Although most laboratories adequately detected tumours with high receptor expression, a large proportion of in house tumours classified initially by participants' staining as being of low or medium ER expression had a higher degree of expression when stained by the UK NEQAS-ICC centre. The efficiency of the organising centre's routine IHC method for ER and PR in optimally demonstrating participants in house breast tumours shows that variations in fixation and tissue preparation are not limiting factors preventing a different laboratory achieving optimal demonstration.

Breast Neoplasms↗

Frequency of oestrogen and progesterone receptor positivity by immunohistochemical analysis in 7016 breast carcinomas: correlation with patient age, assay sensitivity, threshold value, and mammographic screening.

AIMS: A routine immunohistochemical (IHC) assay is now commonly used for determining the oestrogen receptor (ER) and progesterone receptor (PR) status of women with breast cancer. To date, no large studies have been conducted that report the expected frequency of receptor positivity in relation to patient age and sensitivity of the IHC assay. Data on 7016 breast carcinomas from 71 laboratories were analysed to determine the frequency of receptor positivity and investigate possible causes of the observed variation in detection rates. METHODS: Members of UK NEQAS-ICC (UK National External Quality Assessment Scheme for Immunocytochemistry) provided data on the receptor status of cases routinely assayed in their departments over a period of two to 26 months between June 1996 and September 1998. Data on 7016 breast carcinomas were stratified according to patient age and receptor status. Frequency of receptor positivity was correlated with IHC assay sensitivity, the threshold value used to determine receptor positivity, and the presence or absence of mammographic screening in the hospitals or clinics served by the laboratories. RESULTS: The highest proportion of receptor positive cases occurred in patients in the age ranges > 65 years for ER and 41-50 years for PR. There was a significant positive correlation between frequency of receptor positivity and the sensitivity of the IHC assay, for both ER (rs = 0.346; p = 0.019; two tailed) and PR (rs = 0.561; p = 0.003; two tailed). The mean frequency of receptor positivity for laboratories using the same 10% threshold value was 77% for ER (95% confidence interval (CI), 74% to 80%) in laboratories with high sensitivity and 72% (95% CI, 68% to 76%) for those with low assay sensitivity (p = 0.025). For PR, the mean frequency of receptor positivity for laboratories using the same 10% threshold value and having high assay sensitivity was 63% (95% CI, 57% to 69%), and 51% (95% CI, 38% to 65%) for laboratories with assays of low sensitivity (p = 0.022). The mean frequency of ER positivity for laboratories serving hospitals and clinics where mammographic screening does and does not take place was 73.4% and 75.7%, respectively (p = 0.302; two tailed). CONCLUSIONS: Of the parameters investigated, patient age and IHC assay sensitivity were found to be the main variables influencing the frequency of receptor positivity. We recommend the range of receptor values obtained by laboratories achieving high assay sensitivity as a useful guide against which all laboratories can gauge their own results.

Adult↗

[Monoclonal antibodies in oncology: applications in diagnosis, prognosis and prediction of response to therapy on tissue specimens].

Immunohistochemistry (IHC) is the application of antibody methods to slide-based material i.e. cells and tissues. No other technique has so revolutionised the field for the past 50 to date. IHC has become a staple of the histopathology laboratory. The advantages of this technique are obvious: it is simple, fast and cost-effective. IHC is of great help in oncology: to classify a tumor in its category, to identify the origin of a metastasis and in some cases to establish the malignancy of a lesion. The implications of IHC in the determination of prognostic and predictive factors in oncology are still limited, but start to develop, particularly in the field of the detection of hormon receptors and of the overexpression of HER2/neu in breast cancer. Although IHC lacks of reproducibility, the development of quality assurance programs will contribute to the development of IHC in predictive oncology.

Antibodies, Monoclonal↗

[Digitization and image reconstruction: application to iconography of surgical pathology specimens].

A simple method for obtaining imaging documents of surgical specimens is reported. the method uses a scanner and a personal computer with printer. It provides rapid, low-cost high-quality images on paper or transparencies. The document can be used to illustrate a pathology report or discussion between clinicians and pathologists. The computers facilities already present in most Pathology laboratories is sufficient. The scanner with software cost slightly more than a camera.

Humans↗

[Antigenic retrieval using a pressure cooker].

This technical note describes antigen retrieval procedures using a pressure cooker. These procedures are perfectly adapted to routine immunohistochemistry and improve the overall quality of immunostaining.

Antigens↗

[Immunohistochemical evaluation of estrogen and progesterone receptors on paraffin sections of breast carcinomas. Practical thoughts based on the study of 368 cases].

368 formalin-fixed and paraffin-embedded carcinomas of the breast were studied by immunohistochemistry using antibodies to estrogen and progesterone receptors. The results, which are comparable to the results published in the literature, are discussed with particular emphasis on quality assurance parameters.

Breast Neoplasms↗

[Small intestinal tumors with skeinoid fibers. Report of 3 cases with immunohistochemical and ultrastructural study].

Three cases of small intestinal stromal tumors with skeinoid fibers are presented and are confronted to the 15 cases found in the literature. These tumors are characterized by the presence of intercellular eosinophilic globules that stain positively on periodic acid-Schiff stain. Ultrastructurally, these structures are composed of tangles of curved banded (45 nm) fibers simulating an appearance of skeins. By immunohistochemistry, tumor cells express vimentin only. These tumors seem to be derived from the enteric plexus.

Aged↗

Autoimmune pemphigus. A distinct staining pattern with an anti-desmoglein antibody.

BACKGROUND AND DESIGN: Diagnosis of autoimmune pemphigus is based on the immunodetection of IgG deposits in the epidermal intercellular spaces. Desmoglein is a desmosomal component that has been assumed to be the antigen of pemphigus foliaceus. We investigated the use of one monoclonal antibody (32-2B) to desmoglein 1 on paraffin sections. Twenty-nine pemphigus samples were studied (22 pemphigus vulgaris, seven pemphigus foliaceus). RESULTS: In 29 patients suffering from autoimmune pemphigus, the staining for desmoglein was represented by coarse granules along the cytoplasmic borders of epithelial cells in lesional and perilesional skin and in mucous membranes. This peculiar staining is different from the fine dots along the cytoplasmic membrane observed in normal skin. This abnormal staining seems to be specific for pemphigus. Hereditary acantholytic diseases and other diseases such as bullous pemphigoid, intraepidermal IgA dermatosis, eczema, herpes, and transient acantholytic dermatosis show a similar pattern to normal skin. CONCLUSION: The use of 32-2B on biopsy specimens in cases of autoimmune pemphigus demonstrated a specific staining pattern. It could be used on paraffin sections as a diagnostic test of autoimmune pemphigus. It can even be done retrospectively.

Antibodies, Monoclonal↗