PubMed HealthSearch

Biomedical subjects

A J Berry

Publications and source records attributed to A J Berry.

At least 19 recordsLinked to original sources

Tuberculosis makes a comeback.

Tuberculosis (TB) has plagued mankind for many centuries. In the past, the number of people affected with this potentially deadly disease declined, but there has been a recent dramatic increase in TB incidence. This increase is attributed largely to people who are coinfected with TB and HIV and to the development of resistant strains of Mycobacterium tuberculosis during the last decade. The US social infrastructure also has contributed to a rapid rise in TB cases due to adverse socioeconomic factors and an increase in the number of immigrants and people infected with HIV. This article gives a historical overview of TB; discusses its diagnosis, transmission and prevention modalities; and provides a case study about a TB-infected patient who required emergent surgical intervention.

Aged

Percutaneous injuries in anesthesia personnel.

Anesthesia personnel are at risk for occupationally acquired blood-borne infections from human immunodeficiency virus, hepatitis viruses, and others after percutaneous exposures to infected blood or body fluids. The risk is greater after an infected, blood-contaminated, percutaneous injury, especially from a hollow-bore blood-filled needle, than from other types of exposures. Few data are available on the specific occupational hazards to anesthesia personnel from needles and other sharp devices. Fifty-eight percutaneous injuries (PIs) from anesthesia personnel in nine hospitals were analyzed. Thirty-nine of 58 PIs were from contaminated devices (all needles), and 19 were from uncontaminated devices or of unknown contamination status. Forty-three percent of contaminated percutaneous injuries (CPI) were classified as moderate (some bleeding) or severe (deep injury with profuse bleeding), and most were to health-care workers' hands. Fifty-nine percent of CPI were potentially preventable. Eighty-seven percent of CPI were from hollow-bore needles, and 68% of these were potentially preventable. The largest categories of devices causing CPI were needle on syringe, intravenous (i.v.) or arterial catheter needle-stylet, suture needle, and standard hollow-bore needle for secondary i.v. infusion. Most CPI occurred between steps of a multistep procedure (8%), were recapping related (13%), or occurred at other times after use (41%). No CPI were reported from use of needlestick-prevention safety devices. The devices and mechanisms of injury identified in this study provide specific data that may lead to prevention strategies to reduce the risk of PI.

Anesthesiology

Injury prevention in anesthesiology.

Anesthesia personnel routinely perform procedures that put them at risk for contact with blood and body fluids. Some of these exposures are to skin and mucous membranes; many are percutaneous injuries associated with the frequent use of needled devices. The high risk in anesthesia procedures for contact with infected body fluids is associated with a high incidence rate of actual infection with bloodborne pathogens.

Accidents, Occupational

Work hours of residents in seven anesthesiology training programs.

Medical educators and credentialing organizations recently have called attention to the long hours that some house staff are required to spend in the hospital during training. To determine the average duration of in-hospital work hours of anesthesiology residents, 148 residents at seven, university-affiliated training programs kept daily logs of their activities for one week. Residents in clinical anesthesia years 1, 2, and 3 spent an average of 66, 65, and 64 hours per week, respectively, in the hospital with a range of 43 to 104 hours per week. Although there was not a difference in in-hospital work time among years of training, there was a statistical difference between two of the seven programs studied. The largest portion of the in-hospital time was devoted to patient care activities in the operating room. Residents had time for educational activities, conferences, and reading while in the hospital. The overall work hours of the residents in the anesthesiology training programs included in this survey appeared to be within current guidelines.

Anesthesiology

The use of needles in the practice of anesthesiology and the effect of a needleless intravenous administration system.

Anesthesia personnel are at risk for occupationally acquired blood-borne infections transmitted through needlestick injuries. To formulate strategies for the prevention of needlestick injuries, it is necessary to identify the types of needles used by anesthesia personnel and the devices associated with injuries. The introduction of a needleless intravenous (i.v.) administration system provided an opportunity to assess its effect on needle usage in the practice of anesthesiology. The contents of needle disposal containers placed in the preoperative holding area and five operating rooms before (control) and after the introduction of a needleless administration system (study) were categorized by needle type. The information on needles used by anesthesia personnel was compared with that on needles purchased for the entire hospital. During the control period, most of the needles used were 18-23-gauge hollow needles (51.6%), i.c. catheter stylets (23%), and 25-26-gauge small-bore hollow needles (17.1%). There was no difference in the total number of needles collected after the introduction of the needleless administration system, but there was an increase in capped 18-23-gauge hollow needles. Anesthesia personnel used a relatively greater number of small-bore hollow needles (25-26 gauge), i.v. catheters, and spinal and epidural needles, but fewer hollow needles (18-23 gauge) than were purchased for hospital-wide use. Small-bore hollow needles (25-26 gauge) were responsible for 31.6% of the 19 needlestick injuries reported by anesthesia personnel to the Employee Health Service.(ABSTRACT TRUNCATED AT 250 WORDS)

Anesthesiology

Initiating a crystallographic study of a class II fructose-1,6-bisphosphate aldolase.

We have reproducibly crystallized the metal-dependent Class II fructose-1,6-bisphosphate aldolase from Escherichia coli. Crystals in the shape of truncated hexagonal bipyramids have unit cell dimensions of a = b = 78.4 A, c = 290.6 A and are suitable for a detailed structural analysis. The space group has been identified as P6(1)22 or enantiomorph. Data sets to approximately 2.9 A resolution have been recorded using both the Rigaku R-AXIS IIc image plate area detector coupled to a copper target rotating anode X-ray source and using the MAR image plate systems with synchrotron radiation at the EMBL outstation DESY in Hamburg, and at S.R.S. Daresbury. Diffraction beyond 2.5 A has been observed when large freshly grown crystals are used with the synchrotron beam. A data set to this resolution has been collected. Several putative heavy-atom derivative data sets have also been measured using synchrotron radiation facilities and analysis of these data sets is in progress.

Crystallization

The risk of needlestick injuries and needlestick-transmitted diseases in the practice of anesthesiology.

Anesthesiologists are at risk for acquiring blood-borne infections through contact with blood or body fluids. From prospective studies, the greatest risk of transmission is through a percutaneous exposure such as needlestick injury. Personal protective equipment such as gloves and gowns do not completely prevent these exposures. Although educational efforts can reduce the frequency of recapping of needles, they generally have not decreased the incidence of needlesticks. Therefore, in addition to practicing universal precautions, anesthesiologists can attempt to reduce their risk of needlestick injuries by eliminating nonessential unprotected needle use, through the use of needleless or protected needle devices (engineering controls) and by modifying anesthetic procedures requiring needles (work practice controls). Needleless or protected needle products are commercially available for use in many procedures performed by anesthesiologists. For tasks that require the use of needled devices, the practitioner should use safe techniques for handling (i.e., one-handed recapping if recapping is needed) and disposal (i.e., puncture-resistant containers) of these devices. Evaluation of the efficacy, cost, and safety of needleless or protected needle products should be continued as they are introduced into wider use. Additionally, anesthesiologists should be encouraged to report needlestick injuries so that appropriate postexposure treatment can be given and so that the incident can be studied to permit design of a work protocol or device to prevent similar accidents in the future.

Anesthesiology

Use of high-dose fluconazole as salvage therapy for cryptococcal meningitis in patients with AIDS.

Eight patients with AIDS were treated orally with 800 mg of fluconazole daily for cryptococcal meningitis for a mean duration of 4.5 months. Previous antifungal treatment had failed for all of the patients. No major toxicity was observed. Three patients died from cryptococcal infection. High-dose fluconazole may be effective salvage therapy for cryptococcal meningitis.

Acquired Immunodeficiency Syndrome

Lack of polymorphism on the Drosophila fourth chromosome resulting from selection.

Evolutionary processes can be inferred from comparisons of intraspecific polymorphism and interspecific divergence. We sequenced a 1.1-kb fragment of the cubitus interruptus Dominant (ciD) locus located on the nonrecombining fourth chromosome for ten natural lines of Drosophila melanogaster and nine of Drosophila simulans. We found no polymorphism within D. melanogaster and a single polymorphism within D. simulans; divergence between the species was about 5%. Comparison with the alcohol dehydrogenase gene and its two flanking regions in D. melanogaster, for which comparable data are available, revealed a statistically significant departure from neutrality in all three tests. This lack of polymorphism in the ciD locus may reflect recent positive selective sweeps on the fourth chromosome with extreme hitchhiking generated by the lack of recombination. By simulation, we estimate there to be a 50% chance that the selective sweeps occurred within the past 30,000 years in D. melanogaster and 75,000 in D. simulans.

Alcohol Dehydrogenase

An alternative strategy for infection control of anesthesia breathing circuits: a laboratory assessment of the Pall HME Filter.

Contaminated breathing systems have been responsible for nosocomial upper respiratory tract and pulmonary infections in patients undergoing general anesthesia. The current infection control guidelines for anesthesia breathing circuits require single-patient use or high-level disinfection of breathing tubes, y-connector, and reservoir bag. An alternative infection control strategy has been suggested that incorporates placement of a microbial filter downstream from the y-connector between the circuit and the patient. This laboratory study assessed the capacity of the Pall HME Filter as a bidirectional barrier to transmission of bacteria between the y-connector of an anesthesia circle breathing system and a test lung. The investigators modified a sterile circle system to allow aerosolization of a suspension of 10(9) Micrococcus luteus over 5 h into the inspiratory limb proximal to the y-connector or downstream from the filter into the test lung. Cultures indicated that the Pall HME Filter placed between the y-connector and the test lung completely prevented transmission of bacteria in both directions. The results of this study suggest that the Pall HME Filter could be used as an effective microbial barrier between the anesthesia circle breathing system and the patient as part of an alternative strategy for infection control.

Anesthesia, Closed-Circuit

The value of pulmonary artery and central venous monitoring in patients undergoing abdominal aortic reconstructive surgery: a comparative study of two selected, randomized groups.

One hundred two patients undergoing abdominal aortic reconstructive surgery were prospectively, randomly allocated to two groups, one of which was monitored with a central venous catheter and the other with a pulmonary artery catheter. Patients with uncompensated cardiopulmonary or renal disease were excluded from the study. General anesthesia was administered for the surgical procedure, and the patients were followed through hospital discharge. No statistically significant differences occurred between the two groups with regard to morbidity (perioperative cardiac, pulmonary or renal sequelae), mortality rate, duration of intensive care, postoperative hospital stay, or cost of hospitalization. The one statistically significant difference between groups was the professional fee charged for anesthetic care, which was higher for patients with pulmonary artery catheters than for those with central venous catheters. In conclusion, we prospectively gathered data from most patients presented for abdominal aortic reconstructive surgery. Our data seem to indicate that the choice of central venous catheter or pulmonary artery catheter monitoring makes little difference in outcome after abdominal aortic reconstructive surgery, and that for many patients pulmonary artery catheters are not necessary to give appropriate, adequate care. Because of the size of the sample, however, declarations of epidemiologic significance would be unfounded. Therefore large-scale, multicenter studies addressing such outcomes remain necessary.

Anesthesia, General

Eflornithine for the treatment of Pneumocystis carinii pneumonia in patients with the acquired immunodeficiency syndrome: a preliminary review.

Pneumocystis carinii pneumonia (PCP) is the most common opportunistic infection in patients with acquired immunodeficiency syndrome (AIDS). Eflornithine is an antiprotozoal agent active against P. carinii. It acts by inhibiting ornithine decarboxylase, an enzyme that is essential for cellular function. The drug is initially administered intravenously, followed by oral therapy. Eflornithine has been used on a compassionate basis in AIDS patients with PCP who were intolerant of or unresponsive to traditional agents. Overall, the response rate has been about 35%; however, conclusions are difficult to make since patients had different stages of disease and received treatment for varying periods of time. Side effects include depression of bone marrow function, diarrhea, hearing loss, seizures, alterations in liver function tests, and rash. While the need for safer and more efficacious antipneumocystis drugs grows, widespread use of seemingly promising agents should be based on well-conducted clinical trials.

Acquired Immunodeficiency Syndrome