PubMed Health⌕ Search

Biomedical subjects

A J Dempsey

Publications and source records attributed to A J Dempsey.

2 recordsLinked to original sources

Evaluation of linear finite-element analysis models' assumptions for external fixation devices.

Linear finite-element models (FEMs) have enjoyed an increased use in orthopaedic research, including the use for modeling external fixation devices. These fixator FEMs depend on a number of basic assumptions concerning the overall fixation frame stability and the components' rigidity. Among the more important ones are: (i) rigid fixation at both ends of the pin and sidebar; (ii) that the sidebar can be treated essentially as a rigid entity, with all bending occurring in the bone pins; and (iii) that the system can be treated as linearly elastic. Prior work done by the authors questions some of these assumptions. Thus, this study sought an empirical evaluation of the validity of some of these a priori assumptions. A Hoffmann single half-frame was tested in its standard form and then according to a stepwise protocol wherein the frame was welded to eliminate any possible points of instability. These tests looked at the stability and rigidity in various modes (axial compression, torsion, and medial-lateral and anterior-posterior four-point bending). The basic assumptions concerning the frame stability, frame rigidity and the frame's response to loads were found to be erroneous. Component failure was common under minimal loads and statistically significant differences (p less than 0.05) of up to 75% were noted in frame rigidity among the various frame forms tested. Thus, considerable caution must be exercised when employing the FEM technique for evaluating the fixator properties.

Biomechanical Phenomena↗

Stability and anchorage considerations for cementless tibial components.

The ability of several idealized tibial anchorage systems to resist distractive relative motion between the substrate and the component when subjected to eccentric loads was assessed using mechanical tests employing a urethane foam as a bone substitute and finite element models. Eccentric loads had to be placed within 30-35% of the edge of the tibial plate for separation to occur between an unanchored plate and the substrate. The finite element model predicted that a 90%/10% medial/lateral load distribution was required to maintain compressive vertical stresses beneath the unanchored plate. An anchorage system with four pegs each 10 mm in diameter and 20 mm long and an anchorage system with four cancellous bone screws each 6.5 mm in diameter were loaded eccentrically, and both systems prevented distraction of greater than 76 microns when mounted on urethane foam. Shorter pegs (10 mm) or a single central peg allowed distractions of 150 microns or greater to occur. These data are relevant to the design and testing of tibial components for total knee arthroplasty.

Biomechanical Phenomena↗