PubMed Health⌕ Search

Biomedical subjects

A J Dent

Publications and source records attributed to A J Dent.

7 recordsLinked to original sources

A wide-aperture dynamically focusing sagittal monochromator for X-ray spectroscopy and diffraction.

A scanning dynamically focusing sagittal X-ray monochromator accepting 7 mrad of the fan from a 6 T wiggler is in routine use on beamline 16.5 (ultra-dilute spectroscopy) of the SRS at CCLRC Daresbury Laboratory, UK. The energy range covered is 7-27 keV, with a horizontal spot size of <1.1 mm FWHM. Measured monochromatic flux from a Si 220 crystal pair is 1 x 10(11) photons s(-1) (100 mA)(-1) at 9 keV. This level of flux, usually associated with an insertion device on a third-generation source, permits collection of EXAFS data on concentrations at or below 10 ppm.

Equipment Design↗

The new materials processing beamline at the SRS Daresbury, MPW6.2.

A new beamline (MPW6.2) has been designed and built for the study of materials during processing where three synchrotron techniques, SAXS, WAXS and XAS, are available simultaneously. It has been demonstrated that Rietveld refinable data can be collected from silicon SRM 640b over a 60 degrees range in a time scale of 1 s. The data have been refined to a chi(2) of 2.4, the peaks fitting best to a Pearson VII function or with fundamental parameters. The peak halfwidths have been found to be approximately constant at 0.06 degrees over a 120 degrees angular range indicating that the instrumental resolution function has matched its design specification. A quantitative comparison of data sets collected on the same isotactic polypropylene system on MPW6.2 and DUBBLE at the ESRF shows a 17% improvement in angular resolution and a 1.8 improvement in peak-to-background ratio with the RAPID2 system; the ESRF data vary more smoothly across detector channels. The time-dependent wide-angle XRD was tested by comparing a hydration reaction of gypsum-bassanite-anhydrite with energy-dispersive data collected on the same system on the same time scale. Three sample data sets from the reaction were selected for analysis and gave an average chi(2) of 3.8. The Rietveld-refined lattice parameters are a good match with published values and the corresponding errors show a mean value of 3.3 x 10(-4). The data have also been analysed by the Pawley decomposition phase-modelling technique demonstrating the ability of the station to quickly and accurately identify new phases. The combined SAXS/WAXS capability of the station was tested with the crystallization and spinodal decomposition of a very dilute polymer system. Our measurements show that the crystallization of a high-density co-polymer (E76B38) as low as 0.5% by weight can be observed in solution in hexane. The WAXS and SAXS data sets were collected on the same time scale. The SAXS detector was calibrated using a collagen sample that gave 30 orders of diffraction in 1 s of data collection. The combined XRD and XAS measurement capability of the station was tested by observing the collapse and re-crystallization of zinc-exchanged zeolite A (zeolite Zn/Na-A). Previous studies of this material on station 9.3 at the SRS were compared with those from the new station. A time improvement of 38 was observed with better quality counting statistics. The improved angular resolution from the WAXS detector enabled new peaks to be identified.

Equipment Design↗

Effect of Si(IV) substitution on the stability of microporous ZnAPSO-44 solid acid catalysts: a combined XAS/XRD study.

The combined XAS/XRD technique has been used to investigate the stability of the microporous structure during calcination process for a series of ZnAPSO-44 materials. Incorporation of large amounts of Zn is found to produce materials that are unstable upon removal of the structure directing organic template molecule. However, simultaneous incorporation of Si is found to increase the thermal stability of the materials, yielding catalysts that are well suited for acid catalysed reactions.

Journal Article↗

In situ EXAFS, X-ray diffraction and photoluminescence for high-pressure studies.

A new facility for simultaneous extended X-ray absorption of fine structure (EXAFS), X-ray diffraction and photoluminescence measurements under high pressures has been developed for use on station 9.3 at the Daresbury Laboratory Synchrotron Radiation Source. This high-pressure facility can be used at any suitable beamline at a synchrotron source. Full remote operation of the rig allows simultaneous collection of optical and structural data while varying the pressure. The set-up is very flexible and can be tailored for a particular experiment, such as time- or temperature-dependent measurements. A new approach to the collection of high-pressure EXAFS data is also presented. The approach significantly shortens the experimental times and allows a dramatic increase in the quality of EXAFS data collected. It also opens up the possibility for EXAFS data collection at any pressure which can be generated using a diamond cell. The high quality of data collected is demonstrated with a GaN case study. Particular attention will be paid to the use of energy-dispersive EXAFS and quick-scanning EXAFS techniques under pressure.

Journal Article↗

Initial data from the 30-element ORTEC HPGe detector array and the XSPRESS pulse-processing electronics at the SRS, Daresbury Laboratory.

Following the completion of the collaborative project between CLRC Daresbury Laboratory and EG&G ORTEC to develop the world's first 30-element HPGe detector for fluorescence XAFS, it has now been tested and commissioned at the SRS. The system was commissioned with the XSPRESS digital pulse-processing electronics and this has demonstrated processed count rates in excess of 10 MHz. Initial data have been recorded and are presented.

Journal Article↗

Two different zinc sites in bovine 5-aminolevulinate dehydratase distinguished by extended X-ray absorption fine structure.

The zinc coordination in 5-aminolevulinate dehydratase was investigated by extended X-ray absorption fine structure (EXAFS) associated with the zinc K-edge. The enzyme binds 8 mol of zinc/mol of octameric protein, but only four zinc ions seem sufficient for full activity. We have undertaken a study on four forms of the enzyme: (a) the eight-zinc native enzyme; (b) the enzyme with only the four zinc sites necessary for full activation occupied; (c) the enzyme with the vacant sites of (b) occupied by four lead ions; (d) the product complex between (b) and porphobilinogen. We have shown that two structurally distinct types of zinc sites are available in the enzyme. The site necessary for activity has an average zinc environment best described by two/three histidines and one/zero oxygen from a group such as tyrosine or a solvent molecule at 2.06 +/- 0.02 A, one tyrosine or aspartate at 1.91 +/- 0.03 A, and one cysteine sulfur at 2.32 +/- 0.03 A with a total coordination of five ligands. The unoccupied site in (b), obtained by taking the difference spectrum between the spectra from samples (a) and (b), is dominated by a single contribution of four cysteinyl sulfur atoms at 2.28 +/- 0.02 A. Spectra from samples (c) and (d) show only small changes from that of (b), reflecting a slight rearrangement of the ligands around the zinc atom.

Animals↗