PubMed Health⌕ Search

Biomedical subjects

A J Fenn

Publications and source records attributed to A J Fenn.

6 recordsLinked to original sources

Success of sentinel lymph node mapping after breast cancer ablation with focused microwave phased array thermotherapy.

BACKGROUND: Breast cancer tumor ablation as part of a multimodality approach in the treatment of breast cancer is the subject of recent interest. This study was conducted to determine if the ability to perform sentinel node biopsy was impaired after thermal-induced ablation of breast cancer. METHODS: We studied patients who had sentinel node biopsy after preoperative focused microwave phased array for breast cancer ablation. RESULTS: Twenty-one patients with T1-T2 breast cancer and clinically negative axilla underwent wide local excision and sentinel node biopsy guided by blue dye and sulfur colloid. Surgery was done an average of 17 days after microwave ablation. Fifteen of 22 patients (68%) had histologic evidence of tumor necrosis. Sentinel lymph node mapping was successful in 19 of 21 patients (91%). Axillary metastases were detected in 42% of cases. CONCLUSIONS: This study documents successful sentinel lymph node mapping for patients treated with antecedent local tumor ablation using focused microwave phased array ablation.

Axilla↗

Experimental investigation of an adaptive feedback algorithm for hot spot reduction in radio-frequency phased-array hyperthermia.

A computer-controlled adaptive phased array radiofrequency hyperthermia system for improved therapeutic tumor heating is experimentally investigated. Adaptive array feedback techniques are used to modify the electric-field in hyperthermia experiments with a homogeneous saline phantom target. A hyperthermia phased-array antenna system has been modified to implement adaptive nulling and adaptive focusing algorithms. The hyperthermia system is a ring phased-array antenna applicator with four independently controlled RF transmitter channels operating at a CW frequency of 100 MHz. The hyperthermia phased array is made adaptive by software modifications which invoke a gradient-search feedback algorithm that controls the amplitude and phase of each transmitter channel. The gradient-search algorithm implements the method of steepest descent for adaptive nulling (power minimization) and the method of steepest ascent for adaptive focusing (power maximization). The feedback signals are measured by electric-field short-dipole probe antennas. The measured data indicate that with an adaptive hyperthermia array it may be possible to maximize the applied electric field at a tumor position in a complex scattering target body and simultaneously minimize or reduce the electric field at target positions where undesired high-temperature regions (hot spots) occur.

Algorithms↗

Pre-clinical evaluation of a two-channel microwave hyperthermia system with adaptive phase control in a large animal.

A pre-clinical assessment of the heating capabilities of a two-channel 915 MHz Microfocus-1000 hyperthermia system, with adaptive phase control, was carried out in a series of experiments using a large animal model. The results of the experimental measurements of specific absorption rate (SAR) and tissue temperature show that when muscle tissue of the hind legs of pigs was compressed to 6.5-7 cm, then a pair of parallel opposed, coherently driven, transverse electromagnetic wave applicators could elevate the temperature in deep tissue to therapeutic levels without overheating superficial tissues when the phase difference between applicators was determined by the adaptive phase control algorithm.

Animals↗

An adaptive microwave phased array for targeted heating of deep tumours in intact breast: animal study results.

It has previously been reported in phantoms, that an adaptive radiofrequency phased array can generate deep focused heating distributions without overheating the skin and superficial healthy tissues. The present study involves adaptive microwave phased array hyperthermia tests in animals (rabbits) with and without tumours. The design of the adaptive phased array as applied to the treatment of tumours in intact breast, is described. The adaptive phased array concept uses breast compression and dual-opposing 915 MHz air-cooled waveguide applicators with electronic phase shifters and electric-field feedback, to focus automatically by computer control the microwave radiation in deep tissue. Temperature measurements for a clinical adaptive phased array hyperthermia system demonstrate tissue heating at depth with reduced skin heating.

Animals↗

Adaptive radiofrequency hyperthermia-phased array system for improved cancer therapy: phantom target measurements.

A computer-controlled adaptive radio-frequency hyperthermia system for improved therapeutic tumour heating is experimentally investigated. Adaptive array feedback techniques are used to modify the electric-field and temperature distribution in hyperthermia experiments with homogeneous and heterogeneous phantom targets. A commercial hyperthermia phased-array antenna system at the SUNY Health Science Center in Syracuse, New York, has been modified to implement adaptive nulling and adaptive focusing algorithms. The hyperthermia system is the BSD Medical Corporation Model BSD-2000 with Sigma-60 annular phased-array antenna applicator. The transmit phased array system is made adaptive by software modifications which invoke a gradient-search feedback algorithm. The gradient-search algorithm implements the method of steepest descent for adaptive nulling (power minimization) and the method of steepest ascent for adaptive focusing (power maximization). The feedback signals are provided by electric-field short-dipole probe antennas. With an adaptive hyperthermia array using real-time measured data, it may be possible to maximize the applied electric field at a tumour position in a complex scattering target body and simultaneously minimize or reduce the electric field at target positions where undesired high-temperature regions (hot spots) occur. The measured phantom-target data indicate that adaptive nulling can reduce the electric field at one or more target positions while simultaneously focusing the electric field at a deep-seated position within the target.

Algorithms↗