Creatinine biosensors: principles and designs.

Creatinine biosensors, based on both potentiometric and amperometric devices, have been created. However, there are significant problems still to be addressed, including the balance between sensitivity and selectivity, interference rejection and sensor stability. In addition, many devices still rely on a dual-sensor approach for creatine and creatinine subtractive measurements. However, creatinine biosensors appear close to attaining the performance goals necessary for their widespread application. This article looks at the operating principle and design of both potentiometric and amperometric creatinine biosensors, and shows how the design of these devices affects their performance.

Aminohydrolases↗

Rapid antibody biosensor assays for environmental analysis.

Traditionally, biosensor development has focused on molecules with a defined metabolic role that can be exploited by enzyme-based systems. Antibodies have the ability to move beyond this range of analytes, and are particularly useful in detecting small, hapten molecules. Electrochemically based biosensor developments have been less fruitful in this regard, as enzyme labelling is required, and such assays require the separation from bound and unbound species. These separations and the removal of background signals result in the increased complexity of the assay format, making it unsuitable for rapid sensor analysis. We have developed an electrochemical sensor based on antibodies that does not require the separation of bound and unbound molecules in a competition immunoassay format. This removes the need for several washing and separation steps as is normally employed in this type of assay. This allows single-step immunoassays to be performed using this system, and also allows for the real-time monitoring of antibody-antigen interactions. We have shown that such assays are possible in both batch and flow-injection formats and we are currently developing an assay for the pesticide atrazine. Tentative results show that analysis with this system is possible in the p.p.m. to p.p.b. range.

Aniline Compounds↗

Analysis of the glucuronidation of 7-hydroxycoumarin by HPLC.

The in-vitro metabolism of 7-hydroxycoumarin to 7-hydroxycoumarin-glucuronide was investigated in bovine liver homogenate. A metabolic reaction mixture was prepared that included a crude preparation of uridine diphosphate (UDP) glucuronyl transferase, 7-hydroxycoumarin and UDP-glucuronic acid. A HPLC method was developed to separate coumarin, 7-hydroxycoumarin, 7-hydroxycoumarin-glucuronide and an internal standard, 4-hydroxycoumarin. Samples were separated by reverse-phase HPLC, on a C18 column, with a 1 ml min-1 gradient elution with UV detection at 320 nm. The limit of quantification of the method, for 7-hydroxycoumarin-glucuronide, was 1.47 microM, and the linear range was from 0-295.7 microM. Concentrations of 7-hydroxycoumarin-glucuronide produced were calculated from a plot of 7-hydroxycoumarin-glucuronide concentration versus the mean absorbance ratio (n = 4) (7-hydroxycoumarin-glucuronide absorbance/4-hydroxycoumarin absorbance). It was possible to monitor the decrease in the 7-hydroxycoumarin content as it was metabolised as well as the increase in 7-hydroxycoumarin-glucuronide as it was produced enzymatically. The identity of the compound produced was confirmed by photodiode array spectral analysis. A plot of time versus 7-hydroxycoumarin-glucuronide produced indicates that the metabolism is linear for the first 90 min and reached a plateau at 150 min. The rate of reaction in the first 90 min was 2.96 +/- 0.06 (RSD 1.7%, n = 3) nmol of 7-hydroxycoumarin-glucuronide produced per minute per milligram of protein. After 150 min 0.34 +/- 0.005 mM (RSD 1.4%) 7-hydroxycoumarin-glucuronide was produced, from 0.77 mM 7-hydroxycoumarin introduced into the reaction mixture and 58.0% +/- 5.3% (or 0.44 +/- 0.02 mM) of the 7-hydroxycoumarin remained. These results show that it is possible to monitor the production of the phase II metabolite of coumarin with minimal sample clean-up and without the need for deconjugation of the glucuronide moiety. The method was very reliable and applicable for the direct determination of 7-hydroxycoumarin-glucuronide in an in-vitro metabolic assay.

Animals↗

The use of capillary electrophoresis for studying the in vitro glucuronidation of 7-hydroxycoumarin.

An assay utilizing CE, has been developed for studying the in vitro metabolism of 7-hydroxycoumarin to 7-hydroxycoumarin-glucuronide. A reaction mixture containing a crude preparation of bovine uridine diphosphate (UDP) glucuronyl transferase (UDPGT) and the substrates uridine diphosphate glucuronic acid (UDPGA) and 7-hydroxycoumarin was prepared. Aliquots were removed from the reaction mixture at specific time intervals and analyzed on a 57-cm untreated silica capillary for the presence of 7-hydroxycoumarin-glucuronide. Samples were electrophoresed in a 100 mM phosphate/11 mM deoxycholic acid (sodium salt)/acetonitrile electrolyte buffer, pH 7.0, at 30 kV, with detection at 320 nm. The method allowed the determination of 7-hydroxycoumarin-glucuronide without sample cleanup, with a limit of detection of 2 micrograms/mL, and a linear detection range of 0 microgram/mL to 100 micrograms/mL. The 7-hydroxycoumarin-glucuronide, concentrations were calculated from calibration curves of standards prepared in enzyme solution. The initial rate of production of 7-hydroxycoumarin-glucuronide, in the first 70 min, was 3.1 +/- 0.13 nmol/mL/min/mg protein. The method was fast and reliable with percentage relative standard deviations for concentration of 7-hydroxycoumarin-glucuronide, over time, of less than 10%.