PubMed Health⌕ Search

Biomedical subjects

A J Marshall

Publications and source records attributed to A J Marshall.

At least 19 recordsLinked to original sources

16-detector row computed tomographic coronary angiography in patients undergoing evaluation for aortic valve replacement: comparison with catheter angiography.

AIM: To evaluate the diagnostic accuracy of 16-detector row computed tomography (CT) in assessing haemodynamically significant coronary artery stenoses in patients under evaluation for aortic stenosis pre-aortic valve replacement. SUBJECTS AND METHODS: Forty consecutive patients under evaluation for severe aortic stenosis and listed for cardiac catheterization before potential aortic valve replacement underwent coronary artery calcium (CAC) scoring and retrospective electrocardiogram (ECG)-gated multi-detector row computed tomographic coronary angiography (MDCTA) using a GE Lightspeed 16-detector row CT within 1 month of invasive coronary angiography (ICA) for comparative purposes. All 13 major coronary artery segments of the American Heart Association model were evaluated for the presence of > or =50% stenosis and compared to the reference standard. Data were analysed on a segment-by-segment basis and also in "whole patient" terms. RESULTS: A total of 412/450 segments from 35 patients were suitable for analysis. The overall accuracy of MDCTA for detection of segments with > or =50% stenosis was high, with a sensitivity of 81.3%, specificity 95.0%, positive predictive value (PPV) 57.8%, and negative predictive value (NPV) 98.4%. On a "whole-patient" basis, 100% (19/19) of patients with significant coronary disease were correctly identified and there were no false-negatives. Excluding patients with CAC >1000 from the analysis improved the accuracy of MDCTA to: sensitivity 90%, specificity 98.1%, PPV 60%, NPV 99.7%. CONCLUSION: Non-invasive 16-detector row MDCTA accurately excludes significant coronary disease in patients with severe aortic stenosis undergoing evaluation before aortic valve replacement and in whom ICA can therefore be avoided. Its segment-by-segment accuracy is improved further if CAC>1000 is used as a gatekeeper to MDCTA.

Adult↗

Multi-detector row computed tomography: imaging the coronary arteries.

Over the last 2 years, multi-detector row computed tomographic (MDCT) cardiac imaging has continued to rapidly develop and evolve from the experimental research setting to become a useful clinical tool. The increasing availability of MDCT presents today's clinicians with an additional non-invasive diagnostic cardiac imaging method, in particular for the coronary arteries. With the advent and increasing clinical use of 16-detector row machines, and now with the imminent clinical emergence of 64-channel machines, the improvements in spatial and temporal resolution and sophisticated ECG-gating are allowing motion-free, fast, accurate, detailed, contrast-enhanced cardiac imaging that begins to approach the accuracy of traditional invasive diagnostic techniques. Additional diagnostic information may also be provided.

Algorithms↗

Highly accurate coronary angiography with submillimetre, 16 slice computed tomography.

OBJECTIVE: To assess submillimetre coronary computed tomographic angiography (CTA) in comparison with invasive quantitative coronary angiography as the gold standard and to examine the effect of significant coronary artery calcification (CAC), which is known to impede lumen visualisation, on the accuracy of the examination. METHODS: After invasive coronary angiography, 58 patients underwent coronary imaging with a GE Lightspeed 16 computed tomography (CT) system. CAC was quantified after an ECG triggered acquisition with a low tube current. Coronary CTA was performed with retrospective ECG gating and a 16 x 0.63 mm collimation and was reconstructed with an effective 65-250 ms temporal resolution. All 13 major coronary artery segments were evaluated for the presence of > or = 50% stenosis, and compared with the gold standard. RESULTS: One patient moved and could not be evaluated. All segments (except occluded segments) were evaluated for 57 patients. Overall the accuracy of coronary CTA for detection of > or = 50% stenosis was: sensitivity 83%, specificity 97%, positive predictive value 80%, and negative predictive value 97%. The number of diseased coronary arteries was correctly diagnosed in 34 of 38 (89%) patients overall. Altogether 21 of 57 (37%) patients had a CAC score > or = 400, which was predefined as representing significant CAC. Excluding these patients from the analysis improved the accuracy of coronary CTA to a sensitivity of 89%, specificity 98%, positive predictive value 79%, and negative predictive value 99%. CONCLUSIONS: Non-invasive coronary angiography with submillimetre CT is reliable and accurate. It appears that a subgroup of patients may be selected based on CAC score in whom the investigation has even higher accuracy. Coronary CTA has reached the stage where it should be considered for a clinical role. Further research is required to define this role.

Calcinosis↗

Multidetector row computed tomography: imaging congenital coronary artery anomalies in adults.

The quality of the imaging of the main coronary arteries and side branches provided by multidetector row computed tomography (MDCT) may have importance when assessing congenital coronary artery anomalies. This review discusses the rationale for using MDCT for this indication and examines the advantages and disadvantages of the technique. Examples of MDCT imaging of congenital coronary artery anomalies are presented. These images provide persuasive evidence to support clinical use of MDCT cardiac imaging in the context of suspected congenital coronary artery anomalies as a first line investigation.

Adult↗

Multislice computed tomographic coronary angiography: experience in a UK centre.

AIM: To evaluate the technique of coronary angiography with retrospectively electrocardiogram (ECG)-gated four-slice helical computed tomography (CT). MATERIALS AND METHODS: Within 1 month of undergoing routine day-case diagnostic coronary angiography, 30 consecutive patients also underwent retrospectively ECG-gated multislice CT coronary angiography. This enabled direct comparison of seven segments of proximal and mid-coronary artery for each patient by two blinded assessors. Each segment of coronary artery from the multislice CT image was evaluated initially for "assessability" and those segments deemed assessable were subsequently investigated for the presence or absence of a significantly (n=70%) stenotic lesion. RESULTS: Overall 68% of proximal and mid-coronary artery segments were assessable. The sensitivity and specificity of four-slice CT coronary angiography in assessable segments for detecting the presence or absence (n=70%) of stenoses were 72 and 86%, respectively. These results correspond to a positive predictive value of 53% and a 93% negative predictive value. If the 32% of non-assessable segments are added into the calculation then the sensitivity and specificity fall to 49 and 66%, respectively. CONCLUSION: Although multislice CT coronary angiography is a promising technique, the overall assessability and diagnostic accuracy of four-slice CT acquisition is not sufficient to justify routine clinical use. Further, evaluation should investigate the benefit of the reduction in temporal and spatial resolution offered by 16 and 32 slice acquisition.

Coronary Angiography↗

Refined computed tomography of the thoracic aorta: the impact of electrocardiographic assistance.

There have been a number of advances in helical computed tomography (CT) in recent years, which have had a beneficial impact on the quality of imaging of the thoracic aorta. These advances include sub-second gantry rotation, multislice acquisition, and the use of electrocardiographic (ECG) assistance. We examine these techniques with emphasis on the principles behind ECG assistance and its use to reduce aortic motion artefact. We highlight examples of ECG-assisted multislice CT in a spectrum of pathologies of the thoracic aorta.

Aorta, Thoracic↗

Three dimensional volume quantification of aortic valve calcification using multislice computed tomography.

OBJECTIVE: To assess a new multislice computed tomography (CT) technique for three dimensional quantification of aortic valve calcification volume (3D AVCV) and to study the relation between stenosis and calcification of the aortic valve. METHODS: 50 patients with echocardiographic calcification of the aortic valve underwent two separate ECG triggered multislice CT for quantification of 3D AVCV. The agreement between the two 3D AVCV scores was assessed and 3D AVCV was compared with echocardiographic markers of severity of aortic stenosis. RESULTS: Overall the level of agreement between the two 3D AVCV scores was excellent (median interscan variability 7.9% (interquartile range 10.1); correlation coefficient, r = 0.99; repeatability coefficient 237.8 mm3 (limits of agreement -393 to 559 mm3)). However, the magnitude of the 3D AVCV did influence the interscan variability. The 3D AVCV correlated closely with the maximal predicted transvalvar gradient (r2 = 0.77) and aortic valve area (r2 = 0.73). CONCLUSIONS: Multislice CT provides a technique for quantifying 3D AVCV that has good reproducibility. There is a close non-linear relation between echocardiographic parameters of severity of valve stenosis and 3D AVCV scores.

Aged↗

Multislice computed tomography cardiac imaging: current status.

Non-invasive CT coronary artery imaging has previously had little relevance to most UK radiologists due to the limited availability of electron beam CT scanners. Major advances in CT technology have promoted new applications for helical CT, which include cardiac imaging. Widespread installation of 'multislice' helical CT scanners will make CT coronary artery imaging available for the first time in many UK hospitals. The technical advances and early clinical trial data are reviewed and multislice helical CT cardiac imaging in general is discussed.

Aged↗

Comparative effects of permanent biventricular and right-univentricular pacing in heart failure patients with chronic atrial fibrillation.

BACKGROUND: One third of chronic heart failure patients have major intraventricular conduction and uncoordinated ventricular contraction. Non-controlled studies suggest that biventricular pacing may improve haemodynamics and well-being by reducing ventricular asynchrony. The aim of this trial was to assess the clinical efficacy and safety of this new therapy in patients with chronic atrial fibrillation. METHODS: Fifty nine NYHA class III patients with left ventricular systolic dysfunction, chronic atrial fibrillation, slow ventricular rate necessitating permanent ventricular pacing, and a wide QRS complex (paced width >or=200 ms), were implanted with transvenous biventricular-VVIR pacemakers. This single-blind, randomized, controlled, crossover study compared the patients' parameters, as monitored during two 3-month treatment periods of conventional right-univentricular vs biventricular pacing. The primary end-point was the 6-min walked distance, secondary end-points were peak oxygen uptake, quality-of-life, hospitalizations, patients' preferred study period and mortality. RESULTS: Because of a higher than expected drop-out rate (42%), only 37 patients completed both crossover phases. In the intention-to-treat analysis, we did not observe a significant difference. However, in the patients with effective therapy the mean walked distance increased by 9.3% with biventricular pacing (374+/-108 vs 342+/-103 m in univentricular;P =0.05). Peak oxygen uptake increased by 13% (P=0.04). Hospitalizations decreased by 70% and 85% of the patients preferred the biventricular pacing period (P<0.001). CONCLUSION: As compared with conventional VVIR pacing, effective biventricular pacing seems to improve exercise tolerance in NYHA class III heart failure patients with chronic atrial fibrillation and wide paced-QRS complexes. Further randomized controlled studies are required to definitively validate this therapy in such patients.

Aged↗

Churg-Strauss syndrome with critical endomyocardial fibrosis: 10 year survival after combined surgical and medical management.

A case is presented of the Churg-Strauss syndrome with hypereosinophilia and severe cardiac involvement, namely biventricular endomyocardial fibrosis and gross encroachment of the right ventricular cavity. The clinical picture was similar to Loeffler's syndrome and the idiopathic hypereosinophilic syndrome. Combined aggressive surgical and medical management led to full recovery and survival at 10 years. The good long term outcome is attributed to strict control of peripheral eosinophil count by oral corticosteroids. This case illustrates the damaging effects of hypereosinophilia on the heart.

Churg-Strauss Syndrome↗