Evaluation of a pushrim-activated, power-assisted wheelchair.

OBJECTIVE: To evaluate a novel pushrim-activated, power-assisted wheelchair (PAPAW) for compliance with wheelchair standards, metabolic energy cost during propulsion, and ergonomics during selected activities of daily living (ADLs). DESIGN: A 3-phase study, the second and third of which were repeated-measures designs. SETTING: A rehabilitation engineering center within a Veterans Affairs medical center. PATIENTS: Eleven full-time, community-dwelling, manual wheelchair users (4 women, 6 men) with spinal cord injuries or multiple sclerosis. INTERVENTIONS: Phase 1: Compliance testing, with a test dummy, in accordance with the wheelchair standards of the American National Standards Institute and the Rehabilitation Engineering and Assistive Technology Society of North America. Phase 2: Metabolic energy consumption testing-at 2 speeds and 3 resistance levels-in subjects' manual wheelchair and the PAPAW. Phase 3: Evaluation of ability to perform ADLs and ergonomics of the PAPAW compared with the subjects personal wheelchair. MAIN OUTCOME MEASURES: Phase 1: The PAPAW's static stability, static strength, impact strength, fatigue strength, environmental response, obstacle climbing ability, range, maximum speed, and braking distance. Phase 2: Subjects' oxygen consumption per minute, minute ventilation, and heart rate during different speeds and workloads with a PAPAW and their own wheelchairs. Phase 3: Subject ratings of perceived comfort and basic ergonomics while performing selected ADLs. Completion time, stroke frequency, and heart rate during each ADL. RESULTS: Phase 1: The PAPAW was found to be in compliance with wheelchair standards. Phase 2: With the PAPAW, the user had a significantly lower oxygen consumption (&Vdot;O(2)mL/min: p <.0001; &Vdot;O(2)mL/kg x min: p <.0001) and heart rate (p <.0001) when compared with a manual wheelchair at different speeds. Phase 3: The PAPAW had a significantly higher mean ergonomic evaluation (p <.01) than the subjects' personal wheelchairs. The results of comparing the ratings of the car transfer between the PAPAW and the subjects' personal wheelchair showed a significant difference in the task of taking the wheels off (p <.001) and putting the wheels back on (p =.001), with the PAPAW receiving lower ratings. CONCLUSION: This study indicated that the PAPAW is compliant with wheelchair standards, reduces the energy demand placed on the user during propulsion, and that subjects rated its ergonomics favorably when compared with their personal wheelchair. PAPAWs may provide manual wheelchairs with a less physiologically stressful means of mobility with few adaptations to the vehicle or home environment.

Adult↗

Comparison of fatigue life for 3 types of manual wheelchairs.

OBJECTIVES: To examine 3 types of manual wheelchairs-ultralight wheelchairs (UWs), lightweight wheelchairs (LWs), and depot wheelchairs (DWs)-and to compare the fatigue life between the wheelchair types. DESIGN: A database of different manual wheelchairs tested according to the International Organization for Standardization (ISO). Fatigue life was determined by using standards that define methods accepted internationally using double-drum and curb-drop testing equipment. SETTING: A rehabilitation engineering center. SPECIMENS: Sixty-one manual wheelchairs: 25 DWs, 22 UWs, and 14 LWs. MAIN OUTCOME MEASURES: Wheelchairs were examined for differences in fatigue life based on equivalent cycles. Unique survival curves were fit and compared for each wheelchair type. RESULTS: The UWs lasted the longest, with a mean of 309,362 equivalent cycles. The DWs faired the worst, with a mean of 117,210 equivalent cycles. The Kaplan-Meier survival curves were significantly different (p < .001), with the UWs having the longest fatigue life. CONCLUSION: Fatigue life for UWs is significantly greater (p < .05) than LWs and DWs, indicating wheelchairs differ in durability.

Equipment Failure↗

User assessment of manual wheelchair ride comfort and ergonomics.

OBJECTIVE: To examine wheelchair-user perceived ride comfort during propulsion and to compare the ride comfort of ultralight and lightweight manual wheelchairs. An ultralight wheelchair is defined as having a high degree of adjustability, whereas a lightweight wheelchair has minimal adjustability. DESIGN AND PARTICIPANTS: Repeated measures design of a sample of 30 community-dwelling manual wheelchair users evaluating 7 different manual wheelchairs over an activities of daily living course. SETTING: A rehabilitation engineering center. MAIN OUTCOME MEASURES: Subject ratings of perceived ride comfort and basic ergonomics while propelling over the activities of daily living course. Ratings were recorded for each wheelchair on individual tasks and for the course overall. RESULTS: The Invacare Action XT wheelchair was ranked best for both ride comfort and basic ergonomics. The ride-comfort scores (p < .05) and wheelchair ergonomics ratings (p < .05) for the ultralight wheelchair group were significantly different from those for lightweight wheelchair group. CONCLUSION: There are differences in perceived ride comfort and basic ergonomics between the designs of the wheelchairs (lightweight vs ultralight). Subjects perceived that ultralight wheelchairs were more comfortable and had better basic ergonomics than lightweight wheelchairs.

Activities of Daily Living↗

Wheelchair armrest strength testing.

There are about 1.4 million manual wheelchair users, 100,000 electric-powered wheelchair users, and 60,000 electric-powered scooter users. The current study was undertaken to determine if the fasteners of a clamp-type armrest receiver were prone to failure. The first test was used to examine the potential misalignment of the armrest receiver components that attach it to the frame. The second test was to evaluate the entire armrest using the American National Standards Institute/Rehabilitation Engineering and Assistive Technology Society of North America armrest static strength standard. Finally, we conducted three fatigue tests. The first fatigue test was performed by repeating the static stability tests multiple times. The last two tests were a modified version of the double-drum wheelchair fatigue test used to apply repeated loading and vibration simultaneously. A paired t-test showed that there is no statistically significant difference (p = 0.08), with a confidence of 95%, between critical alignment measurements. The armrest including the receiver passed the standard requirement of a force of 760 N being applied outward at 15 degrees. During fatigue testing, we found that armrests did not exhibit any visible or functional damage. Upon completion of the tests, the armrests and receivers functioned properly. At about 100,289 cycles on a double-drum test machine, three bolts failed on each armrest receiver when the screws were loosened to have only five threads engaged prior to commencing the test. The design of the armrest tested was in compliance with existing national and international standards. Currently, both International Standards Organization and American National Standards Institute/Rehabilitation Engineering and Assistive Technology Society committees are developing standards for seating systems that will include static, impact, and fatigue strength testing of devices like lateral torso supports, lateral hip support, etc. Methods similar to those explored in this study should be considered. This study may help manufacturers when designing products and purchasers or regulatory agencies when attempting to evaluate the safety and quality of armrest assemblies.

Equipment Design↗

Displacement between the seating surface and hybrid test dummy during transitions with a variable configuration wheelchair: a technical note.

Changing seating posture can extend the amount of time a person can safely remain seated without damaging tissue or becoming fatigued. The Excelsior is an electrically powered wheelchair that utilizes sit-to-stand (STS) and sit-to-recline (STR) motions to aid in pressure relief. The motion of the wheelchair seating system must closely follow anatomical paths or ulcers may develop from the resulting shear forces. Displacement between the person and the wheelchair seating surface is one measure of these shear forces. The displacement between a Hybrid II 50th percentile anthropometric test dummy (ATD) and the seating surface of the Excelsior wheelchair was examined during STS and STR with two cushions, a Jay Active and a low-profile Roho cushion. The difference between the backrest and ATD back angles were 4.29 degrees +/- 2.13 degrees and 1.78 degrees +/- 1.73 degrees for the Roho and Jay cushions respectively during STS and 3.32 degrees +/- 4.21 degrees and 10.71 degrees +/- 6.20 degrees during STR. These were statistically significant at p<.05. During STS, shear displacement between the Hybrid II back and Excelsior backrest did not exceed 1.5 cm for either cushion. ATD thigh-to-seat displacements were 2.5 cm for the Jay and 3.0 cm for the Roho cushion. STR produced dummy thigh-to-seat displacements of 1.5 cm and 3.5 cm for the Jay and Roho cushions respectively. Shear displacement in the ATD back was about 3.5 cm for the Roho and 6 cm for the Jay. The latter displacement should be reduced; however, the other conditions are marginal or acceptable. Hysteresis was acceptable or better for all cushion/motion combinations, with the highest net displacement of about 2.5 cm.

Biomechanical Phenomena↗