Sequence and task analysis of instrument use in common laparoscopic procedures.

BACKGROUND: In the area of instrument evaluation, one aspect that still requires objective assessment is the dynamics of instrument maneuver and exchange. If we could gain a better understanding of these phenomena, we could improve the design of the instruments themselves. METHODS: A total of 29 laparoscopic procedures were videotaped and reviewed using time motion analysis. Instrument multifunctionality was determined using a standardized list of laparoscopic maneuvers. State transition diagrams were utilized to document the sequence of instrument exchanges. RESULTS: The curved dissector, atraumatic grasper, and cautery scissors were identified as the most multifunctional instruments; each was able to perform five distinct maneuvers. Instrument sequences were found to consist of a three-part dissect --> clip --> cut cycle and a two-part dissect --> suction cycle of instrument exchange. CONCLUSION: This study demonstrated that laparoscopic instruments are often used to perform a variety of maneuvers in addition to their primary function. Furthermore, there are common patterns in instrument exchange that provide a potential source of design parameters for improved surgical efficiency.

Humans↗

Modifications in surgical implantation of the Penn State electric total artificial heart.

BACKGROUND: Two modifications of the surgical implantation protocol for the Penn State Total Artificial Heart (ETAH) were evaluated: Phrenic nerve ischemia was prevented by minimizing dissection and traction; and hemostasis was augmented and ETAH cuff anastomoses reinforced by using fibrin glue. METHODS: Thirteen Holstein calves underwent orthotopic surgical implantation of the Penn State ETAH between February 1998 and August 2000. Mean hemodynamic and laboratory chemistry variables from the first postoperative week were compared between calves receiving the original (n = 7) and modified (n = 6) protocol. RESULTS: Calves assigned to the modified protocol displayed an improvement in the Po2/FiO2 ratio compared to original (419.4 +/- 17.5 vs 336.3 +/- 35.4, respectively; p = 0.05). All additional parameters were equivalent between groups. The percent survival of animals receiving the modified protocol at 2, 4, and 12 weeks was higher than that of animals that underwent the original protocol. Original-protocol calf deaths consisting of hemothorax (n = 3), and respiratory failure (n = 1) were prevented in the modified protocol. CONCLUSIONS: Our results suggest that manipulations in surgical protocol may promote increased survival in calves implanted with the Penn State ETAH.

Animals↗

The LionHeart LVD-2000: a completely implanted left ventricular assist device for chronic circulatory support.

Management of patients with end-stage cardiac disease remains a vexing problem. Limitations in medical management and a fixed supply of donor organs for cardiac transplant have a continued impact on this growing population of patients. Mechanical circulatory support has proved very successful as a means of bridging patients to cardiac transplant when all medical options have been exhausted. The development of a chronic system of circulatory support has been underway at the Pennsylvania State University for nearly 30 years. These efforts have been recently merged with the industrial partnership with Arrow International toward the development of the LionHeart LVD-2000 (Arrow International, Reading, PA) completely implanted left ventricular support system. We present an overview of the system, details of implantation, a review of preclinical studies, and a synopsis of the first European implants. Early results have demonstrated the system to be safe, effective, and reliable. Transcutaneous energy transmission and the compliance chamber have been validated.

Animals↗

A virtual reality surgical trainer for navigation in laparoscopic surgery.

A virtual reality trainer was designed to familiarize students and surgeons with surgical navigation using an angled laparoscopic lens and camera system. Previous laparoscopic trainers have been devoted to task or procedure training. Our system is exclusively devoted to laparoscope manipulation and navigation. Laparoscopic experts scored better than novices in this system suggesting construct validity. The trainer received favorable subjective ratings. This simulator may provide for improved navigation in the operating room and become a useful tool for residents and practicing surgeons.

Computer Simulation↗

Carotid and aortic baroreflexes of the rat: II. Open-loop frequency response and the blood pressure spectrum.

To determine the relationship between blood pressure (BP) variability and the open-loop frequency domain transfer function (TF) of the baroreflexes, we measured the pre- and postsinoaortic denervation (SAD) spectra and the effects of periodic and step inputs to the aortic depressor nerve and isolated carotid sinus of central nervous system-intact, neuromuscular-blocked (NMB) rats. Similar to previous results in freely moving rats, SAD greatly increased very low frequency (VLF) (0.01-0.2 Hz) systolic blood pressure (SBP) noise power. Step response-frequency measurements for SBP; interbeat interval (IBI); venous pressure; mesenteric, femoral, and skin blood flow; and direct modulation analyses of SBP showed that only VLF variability could be substantially attenuated by an intact baroreflex. The -3-dB frequency for SBP is 0.035-0.056 Hz; femoral vascular conductance is similar to SBP, but mesenteric vascular conductance has a reliably lower and IBI has a reliably higher -3-dB point. The overall open-loop transportation lag, of which </=0.1 s is neural, is approximately 1.07 s. Constrained algebraic solution, over a range of frequencies, of the pre- and postSAD endogenous noise spectra and the independently determined relative frequency and absolute lag measurements was used to calculate the absolute gain for the open-loop TF. The average gain at 0.02 Hz, the frequency of maximum sensitivity, was 1.47 (95% confidence interval = +/-0.48), which agrees well with estimates for the dog reversible sinus. We found that, in the NMB rat, the effects of SAD on the BP noise spectrum were accounted for by the open-loop properties of the baroreflex.

Animals↗

In vivo and in vitro stability of modified poly(urethaneurea) blood sacs.

In the present study, we investigate the in vivo and in vitro stability of modified poly(urethaneurea) (BioSpan MS/0.4) blood sacs. Blood sacs were utilized primarily in left ventricular assist devices that were implanted in calves for times ranging from 5 to 160 days. Cyclic testing in vitro was also conducted on similar sacs. Various analytical methods were employed to characterize the sacs after in vivo or in vitro service and corresponding retained "control" sacs. These methods included ATR-FTIR spectroscopy, scanning electron microscopy and gel permeation chromatography. In general, the characteristics of implanted and in vitro cycled sacs were similar to their control sacs. Thermal and microtensile properties were unchanged after testing. The same was true for the ATR-FTIR spectra, indicating relative chemical stability for the time frames explored here. The only significant changes occurred in molecular weight and gross surface morphology. A modest increase in weight average molecular weight was observed for most implanted blood sacs, indicating some type of chain extension or branching reaction in vivo. Although the surface morphologies of implanted blood sacs were often similar to their control sacs, we sometimes observed limited pitting on the nonblood contacting surfaces in regions of the sac that experience maximum bending during service.

Animals↗

An investigation of the in vivo stability of poly(ether urethaneurea) blood sacs.

In this paper we investigate the biostability of a series of Biolon blood sacs that were utilized in electric total artificial hearts for time periods of up to 19 weeks. A battery of experimental probes, including scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS), were used to characterize the bulk and surface properties of explanted and control blood sacs. Gel permeation chromatography (GPC) experiments showed that generally there was a dramatic increase in average molecular weight at longer implantation times. However, SEM and GPC observations suggest significant deterioration of the flex regions of right blood sacs after 17 weeks of service. XPS experiments indicated appreciable silicon and hydrocarbon concentrations on blood-contacting surfaces both before and after implantation, and we speculate as to their origin.

Animals↗

Dynamic in vitro and in vivo performance of a permanent total artificial heart.

In vivo characterization studies were performed to compare the dynamic in vivo performance of the Penn State/3M Health Care electric total artificial heart to existing in vitro data. Fully implanted systems were utilized including the artificial heart, controller, backup batteries, compliance chamber, and transcutaneous energy transmission. Catheters were implanted to measure central venous pressure (CVP), left atrial pressure (LAP), right atrial pressure (RAP), pulmonary artery pressure (PAP), and aortic pressure (AoP). Cardiac output (CO) was determined from the implanted controller, and systemic vascular resistance (SVR) was calculated. Steady state data were collected for each animal along with data regarding the transient responses to changes in preload and afterload. Preload was manipulated through volume changes. Afterload changes were accomplished through vasoactive agents. Increased preload caused little change in cardiac output because the pump output was nearly maximum at baseline. LAP, AoP, and SVR increased with increasing RAP. Decreased preload caused a reduction in CO, LAP, and SVR. Afterload increase resulted in a slight decrease in flow and an increase in system power and SVR. Afterload reduction was accompanied by a decrease in preload and a concomitant reduction in flow. Overall, the system response was similar to the response observed in vitro.

Animals↗

Physiological control of a total artificial heart: conductance- and arterial pressure-based control.

To obtain a physiological response by a total artificial heart (TAH), while eliminating the hemodynamic abnormalities commonly observed with its use, we proposed the use of a conductance- and arterial pressure-based method (1/R control) to determine TAH cardiac output. In this study, we endeavored to make use of a variable more closely tied to central nervous system (CNS) efferents, systemic conductance, to provide the CNS with more direct control over the output of the TAH. The control equation that calculates the target cardiac output of the TAH was constructed on the basis of measurement of blood pressures and TAH flow. The 1/R control method was tested in TAH-recipient goats with an automatic method by using a microcomputer. In 1/R control animals, the typical TAH pathologies, such as mild arterial hypertension and substantial systemic venous hypertension, did not occur. Cardiac output varied according to daily activity level and exercise in a manner similar to that observed in natural heart goats. These results indicate that we have determined a control method for the TAH that avoids hemodynamic abnormalities exhibited by other TAH control systems and that exhibits physiological responses to exercise and daily activities under the conditions tested. The stability of the control and the complete lack of inappropriate excursions in cardiac output is suggestive of CNS involvement in stabilizing the system.

Animals↗

Aortic pressure estimation with electro-mechanical circulatory assist devices.

An adaptive technique for the estimation of the time history of aortic pressure (from applied voltage and position feedback) has been designed, implemented, and bench tested using the Penn State Electric Ventricular Assist Device (EVAD). This method, known in the field of automatic control as a dynamic observer, utilizes gains which were determined using experimental data collected while the EVAD was running on a mock circulatory system. An adaptive scheme provides the observer with a method of changing its initial conditions on a stroke-by-stroke basis which improves observer performance. In both determining the feedback gains and developing the adaptation scheme, a range of beat rates and pressure loads was taken into account to yield satisfactory observer performance over a range of operating conditions. The observer was implemented, its performance was verified in vitro and results are reported. In the six experimental operating conditions, the beat rate ranged from 56-104 beats per minute (bpm) and the span of the mean systolic aortic pressure was 10.7-18.7 kPa (80-140 mmHg). For these cases, the mean deviation between the actual and estimated aortic pressure during the latter two-thirds of systole was 0.41 kPa (3.1 mmHg).

Algorithms↗

Brachymetatarsia. Axial lengthening by using the callus distraction technique.

The authors present a modified approach to the ilizarov callus distraction technique for bone lengthening on a patient with brachymetatarsia. This approach has certain advantages and disadvantages that will be discussed along with historical methods of treating brachymetatarsia. The actual case history, surgical technique, and perioperative care of the patient are described in detail.

Adolescent↗

A long-term ventricular assist system.

An implantable, electrically powered pump that will provide tether-free circulatory support is being developed. The blood pump consists of a seamless polyurethane sac within a polysulfone case. Björk-Shiley Monostrut valves provide unidirectional flow. The blood sac is compressed by a pusher plate with a stroke of 1.9 cm and actuated by a brushless direct-current electric motor and motion translator. The current unit is completely sealed, and inductive coupling techniques provide the electrical energy. The system has an implantable electronic control system as well as a battery that provides 30 minutes of operation when the external coil is disconnected. During normal operation, however, the pump is powered by a portable battery pack or by house current. The unit can pump 8.5 L/min at physiologic pressures. Twenty-six animals have had circulatory support for a period of more than 1 week. The average period of pumping was 62 days; the longest was nearly 8 months. Experiments were terminated in 18 animals because of pump-related problems and in 8 because of biologically related problems. Studies to date are very encouraging and suggest that, with further refinement, a reliable 2-year assist pump that will have important clinical application can be developed.

Animals↗

Noninvasive control of cardiac output for alternately ejecting dual-pusherplate pumps.

An artificial heart should be controlled in a noninvasive fashion; the presence of the control system should pose no risk to the patient. Ideally, much of the control function would be attained passively, by designing the pumps and energy converter so that they naturally respond in an appropriate manner to changes in the circulation. We present methods of controlling both left-right output balance and providing response to changing demands for blood flow for a class of total artificial hearts with implanted energy converters. Our balance control actively maintains left-right balance, but does so in concert with the natural response of the pumps to changes in filling pressures. Cardiac output (CO) can be made to be sensitive to right atrial pressure, but peripheral resistance is our usual cue. Alternative means of determining the correct cardiac output are discussed.

Cardiac Output↗

A soft fibroma.

Explore the source record for details and available documents.

Fibroma↗

An electric artificial heart for clinical use.

Advances in microelectronics, high-strength magnets, and control system design now make replacement of the heart using an implantable, electrically powered pump feasible. The device described herein is a compact, dual pusher plate unit with valved polyurethane sac-type ventricles positioned at either end. The power unit consists of a small, brushless direct current motor and a motion translator. A microprocessor control system is used to regulate heart beat rate and provide left-right output balance. Bench studies lasting for as long as 1 year have been performed. Heart replacement with the electric heart has been performed in 18 calves since 1984. The longest survivor lived for more than 7 months. Among the causes of termination were component failure, thromboembolic complications, and bleeding. No major problem has been identified that precludes prolonged use of the electric heart. In the future the patient with end-stage heart disease will have an electric artificial heart as one therapeutic option.

Animals↗

Permanent circulatory support systems at the Pennsylvania State University.

Permanent circulatory support systems are required for patients in whom myocardial damage is irreversible and cardiac transplantation is not possible. Two systems are described which provide long term circulatory support: the left ventricular assist system and the total artificial heart. These systems are based on the design of a pusher plate actuated blood pump, driven by a small brushless dc electric motor and rollerscrew driver. An implantable motor controller maintains suitable physiologic flow rates for both systems and controls left-right balance in the total artificial heart. Other parts of the system include an intra-thoracic compliance chamber, transcutaneous energy and data transmission system, and internal and external batteries.

Animals↗