Biomedical subjects
A J Wilson
Publications and source records attributed to A J Wilson.
Dynamic responses to tube breathing during the first 10 days of life.
To assess whether there is a maturation of the response to tube breathing during the first 10 days of life, we have measured the dynamic ventilatory responses of nine term infants (34 studies) to added tubes equivalent to two anatomical dead spaces. Such a method allows an assessment of the baby's ability to increase dead space ventilation in response to an added stress. There was a significant improvement with age over the first 10 days in the babies' ability to reach "expected" values of minute ventilation when the tubes were added (P = 0.003). The rates at which 63% and maximum adaptation were achieved also increased significantly with age (P less than 0.005). The rate to 63% adaptation appeared to be faster in active compared with quiet sleep (P less than 0.05). The dynamic responses to tube breathing improve over the first 10 days of life. This is likely to be due to a maturation of peripheral chemoreceptor control, although improving lung mechanics may also be important.
Imaging the hand and wrist.
Explore the source record for details and available documents.
Heart rate variability in infants subsequently suffering sudden infant death syndrome (SIDS).
To study the role of the autonomic cardiovascular control in SIDS the heart rate variability (HRV) was analysed from 24 tape recordings made from a prospective population-based study on 16 term and one preterm infant suffering SIDS and compared to similar data on 23 control infants matched on birthweight, gestation and postnatal age. The number of regular breathing segments was lower in the SIDS cases than in controls (P = 0.02). No significant differences were found between the SIDS cases and their controls for average heart rate, median breathing rate, indices of overall and beat-to-beat HRV. Neither were significant intergroup differences found when the subjects were divided into neonatal and postneonatal subgroups. Analysis of HRV by power-spectral techniques did not show any significant differences between SIDS cases and controls for the general distribution of power or for the respiratory HRV. Analysis of HRV did not differentiate infants destined to die of SIDS from surviving controls in the same population.
Correlations between cardiorespiratory measures in normal infants and victims of sudden infant death syndrome.
Coordination between physiological measures (i.e., the tendency for measures to co-vary with each other) develops with maturation in the infant. We hypothesized that correlations between cardiorespiratory measures would increase with maturation in normal infants and that infants destined to die of sudden infant death syndrome (SIDS) would show lower correlations than those of age-matched controls. Twenty-two recordings of electrocardiogram and respiratory movements were obtained from infants who subsequently succumbed to SIDS and compared with 66 recordings from control infants. Each 1-min epoch of data was sleep-state classified. Median heart and respiratory rate, respiratory variability, and median extent of three types of heart rate variation were determined for each epoch, and the minute-by-minute correlations between seven pairs of parameters were determined for quiet sleep, rapid eye movement sleep, and waking in each recording. Most cardiorespiratory measures showed correlations that increased with age; the correlation coefficients for these measures tended to be lower in SIDS victims than in controls prior to 2 weeks of age. The correlations between heart rate and heart rate variability became lower with maturation; correlations between these measures tended to be higher in the SIDS victims. In all analyses showing significant maturational trends, the SIDS victims showed "less mature" correlations than those of the controls.
Effect of additional cations on the twitching reaction to intracarotid, nonionic contrast media in rabbits.
Previous investigations in this laboratory have confirmed the observation of facial muscle twitching during intracarotid injections of nonionic contrast media (CM) in rabbits. The reaction appears to be a locally mediated effect. To further investigate this reaction, cortical electroencephalogram (EEG) and facial electromyogram (EMG) recordings were made from rabbits receiving selective internal carotid artery (ICA) and external carotid artery (ECA) injections of CM. The effects of iopromide and iohexol were compared with and without the addition of sodium (Na) and calcium (Ca) ions at different concentrations. External carotid injections of iopromide also were performed in some animals paralyzed with D-tubocurarine to exclude the possibility that the reaction is due to an effect on peripheral nerves. The addition of between 5 and 20 mM Ca ions to both CM prevented the reaction but while the addition of Na ions (up to 150 mM) to iopromide had some preventative effect, it did not totally abolish the reaction. In those animals paralyzed with D-tubocurarine, the reaction to iopromide, as observed and recorded by EMG, was the same as that occurring in nonparalyzed animals. This finding is consistent with this reaction being independent of the peripheral nervous system.
Chemotoxic effects of low-osmolar contrast media on the blood-brain barrier.
Explore the source record for details and available documents.
Veterinary profession in the EC.
Explore the source record for details and available documents.
Abnormal jejunal potential difference in cystic fibrosis.
Transmucosal potential difference (PD) and intraluminal pressure were recorded from the same jejunal site in 15 healthy adult controls and 4 adults with cystic fibrosis. In the controls, runs of contractions were associated with wave-like changes in PD with, during phase III-like activity, a mean peak amplitude of -9.7 mV. Although there were no obvious differences in motor patterns, wave-like changes in PD were absent in patients with cystic fibrosis. Intraluminal boluses of 4 mg pilocarpine, or 0.1 mg prostaglandin E2, caused changes of -4.6 mV and -4.5 mV, respectively, in controls; these responses were not seen in patients with cystic fibrosis. There were no significant differences in basal PD and PD changes caused by altered concentrations of infused saline or glucose between patients and controls.
Explicit Fourier representations of non-ideal hypercentric P.D.F.'s of magnitude of E.
Explicit non-ideal hypercentric distributions of the magnitude of the normalized structure factor have been derived and investigated for the space group P1. One of the distribution types investigated arises when the asymmetric unit of P1 consists of several identical centrosymmetric motifs, interrelated by additional non-crystallographic centres of symmetry. The ideal version of such distributions was studied by Rogers & Wilson [Acta Cryst. (1953), 6, 439-449]. The other distribution type studied originates from atomic arrangements in which the asymmetric unit is composed of several unrelated centrosymmetric fragments that may differ in their sizes and chemical compositions. Explicit non-ideal probability density functions (p.d.f.'s) of the magnitude of the normalized structure factor were formulated for both above types of distribution as Fourier series, were evaluated numerically and were compared with appropriately simulated distributions of magnitude of E. The computations were carried out for a range of atomic compositions, and numbers of unrelated centrosymmetric fragments that comprise the asymmetric unit; both of these factors have a significant influence on the deviation of the hypercentric p.d.f.'s from the values predicted on the basis of the central-limit theorem approximation.
Do lung volumes change with sleep state in the neonate?
We have studied 12 healthy full-term babies, mean age 3.2 days, using physiological criteria--EEG, electrooculogram, electromyogram, respiratory regularity and visible movement--to assess sleep state, and a respiratory jacket to record changes in functional residual capacity (FRC). A total of 593 min of sleep data were analysed. Of the recordings, 39% were scored as quiet sleep, 40% as active and 21% as indeterminate sleep. The mean maximum variation in FRC overall was 29 ml (SD +/- 15.4 ml). Examination of these figures showed that FRC variations during sleep state changes were smaller than those seen within a defined sleep state. We conclude that changes in sleep state are not associated with variations in FRC.
Heart rate variation in normal infants and victims of the sudden infant death syndrome.
Infants who later succumb to the sudden infant death syndrome (SIDS) exhibit lower overall heart rate variability during waking than do other infants. This study attempts to determine which type or types of heart rate variation are reduced in SIDS victims. Long-term recordings of heart rate and respiration were obtained from normal infants and infants who later died of SIDS, and heart rate variation in three frequency bands was examined: respiratory sinus arrhythmia (periods 0.9-3.0 s), 'mid-frequency' (periods 4.0-7.5 s) and 'low-frequency' (periods 12-30 s). All three types of heart rate variation were diminished in SIDS victims under 1 month of age during waking and rapid eye movement (REM) sleep compared with controls. Partitioning heart rate effects showed that in waking, and to a lesser extent in REM sleep, the reduction in all types of heart rate variation exceeded that which would have been predicted based on higher heart rates in SIDS victims. No heart rate-independent reduction in any type of heart rate variation was observed in quiet sleep. This state-dependent reduction in three types of heart rate variation could indicate an abnormality of autonomic control mechanisms during waking and REM sleep in infants who later succumb to SIDS.
Subarachnoid anaesthesia with 0.25% isotonic bupivacaine for caesarean section.
Explore the source record for details and available documents.
Shoulder joint: arthrographic CT and long-term follow-up, with surgical correlation.
One hundred two computed tomographic (CT) arthrograms of the shoulder were retrospectively reviewed and compared with conventional double-contrast arthrograms from 101 patients (24 females and 77 males aged 9-70 years). One- to 4-year follow-up was obtained in 84 patients, 40 of whom underwent open-shoulder surgery or arthroscopy. Morphology of the normal portions of each labrum was categorized according to length, width, and tip shape. Correlation between morphology and age was weak, but abnormal labra were more common in younger patients. Conventional radiography was more accurate for detecting bony glenoid margin fractures, but CT was more accurate for detecting Hill-Sach fractures. CT was also more reliable than conventional arthrography in the detection of rotator cuff tears. Hence, few if any conventional radiographs are necessary between contrast material injection and CT imaging. A reduction in the number of images obtained will result in decreased radiation dose, less cost, and shorter examination time without loss of diagnostic accuracy.
Ascending lower limb phlebography: comparison of ioversol and iothalamate meglumine.
Fifty patients undergoing ascending phlebography of a lower limb were evaluated, in a randomized double-blind fashion, to compare the efficacy, patient tolerance, and safety of two different contrast agents. Ioversol-240 (MP-238), a new nonionic agent, and iothalamate-202 (Conray 43), an established ionic agent, were the contrast agents used. Twenty-five patients were injected with iothalamate and 25 with ioversol. The phlebograms were evaluated for diagnostic quality and the patients for symptoms, with special reference to complaints of heat and pain. No significant difference was demonstrated between the two agents in either examination quality or patient tolerance. No major contrast-related reactions were recorded. We conclude that ioversol-240 appears to be a safe and acceptable alternative to iothalamate-202.
Nonarticular soft tissues.
Explore the source record for details and available documents.
Levels of airborne man-made mineral fibres in dwellings in the UK: results of a preliminary survey.
Levels of airborne man-made mineral fibres (MMMF) were measured during the insulation of lofts and after the disturbance of the insulation wools. Transmission electron microscopy was used for the analysis. Generally, the personal samples showed fibre levels of up to 0.7 f/ml, whereas static samples showed fibre levels of 0.05 f/ml in the lofts. Little contamination of living space occurred during these operations.
Sinus tachycardia in term infants preceding sudden infant death.
The quantities of sinus tachycardia in 24-h recordings of the electrocardiogram from 16 full-term infants (greater than or equal to 37 weeks gestation) who were subsequently victims of the sudden infant death syndrome (SIDS), from 230 randomly selected age-matched full-term survivors and from 64 full-term survivors matched for age and birth weight were measured by computer and manual analysis techniques. Of 16 infants dying of SIDS, 7 had elevated levels of sinus tachycardia (greater than 95th centile in controls) (P less than 0.01). Although high levels of sinus tachycardia might be of value in identifying infants at high risk of SIDS, these encouraging findings must first be validated by further prospective studies.