PubMed Health⌕ Search

Biomedical subjects

A J de Mello

Publications and source records attributed to A J de Mello.

6 recordsLinked to original sources

A high-pressure interconnect for chemical microsystem applications.

A PEEK interface for use in microfluidic applications is designed, fabricated and tested. The interface allows for the facile, non-permanent coupling of standard capillary tubing to silicon/glass micromixer chips. Importantly, the interface provides for a secure connection between capillary lines and chip reservoirs without the need for any adhesive materials. Furthermore, when used in conjunction with silicon/glass micromixer chips fluidic transport is stable over a wide range of volumetric flow rates (1-1500 microL min(-1)), and the entire construct can be rapidly assembled and disassembled at any time during the course of experimentation.

Journal Article↗

A capillary electrophoresis chip for the analysis of print and film photographic developing agents in commercial processing solutions using indirect fluorescence detection.

The separation and detection of both print and film developing agents (CD-3 and CD-4) in photographic processing solutions using chip-based capillary electrophoresis is presented. For simultaneous detection of both analytes under identical experimental conditions a buffer pH of 11.9 is used to partially ionise the analytes. Detection is made possible by indirect fluorescence, where the ions of the analytes displace the anionic fluorescing buffer ion to create negative peaks. Under optimal conditions, both analytes can be analyzed within 30 s. The limits of detection for CD-3 and CD-4 are 0.17 mM and 0.39 mM, respectively. The applicability of the method for the analysis of seasoned photographic processing developer solutions is also examined.

Buffers↗

Microchip-based synthesis and analysis: control of multicomponent reaction products and intermediates.

A miniaturised-SYNthesis and Total Analysis System (mu SYNTAS) was used for the solution-phase synthesis and on-line analysis (TOF-MS) of Ugi multicomponent reaction (MCR) products. This approach provides an unusually high degree of control of the MCR and delivers detailed, novel information on reaction intermediates in real-time. Specifically, the Ugi 4 component condensation (4CC) involving the reaction of an amine, acid, aldehyde and isocyanide species was performed at room temperature in a controllable fashion. Furthermore, observation of the nitrilium intermediate, cyclohexyl(2-piperidin-1-ylethylidyne)ammonium chloride, is presented for the first time.

Journal Article↗

Velocity measurement of particulate flow in microfluidic channels using single point confocal fluorescence detection.

This article presents a non-invasive, optical technique for measuring particulate flow within microfluidic channels. Confocal fluorescence detection is used to probe single fluorescently labeled microspheres (0.93 microm diameter) passing through a focused laser beam at a variety of flow rates (50 nL min(-1)-8 microL min(-1)). Simple statistical methods are subsequently used to investigate the resulting fluorescence bursts and generate velocity data for the flowing particles. Fluid manipulation is achieved by hydrodynamically pumping fluid through microchannels (150 microm wide and 50 microm deep) structured in a polydimethylsiloxane (PDMS) substrate. The mean fluorescence burst frequency is shown to be directly proportional to flow speed. Furthermore, the Poisson recurrence time and width of recovered autocorrelation curves is demonstrated to be inversely proportional to flow speed. The component-based confocal fluorescence detection system is simple and can be applied to a diversity of planar chip systems. In addition, velocity measurement only involves interrogation of the fluidic system at a single point along the flow stream, as opposed to more normal multiple-point measurements.

Microscopy, Confocal↗

Photophysics of ethidium bromide complexed to ct-DNA: a maximum entropy study.

Time-integrated and time-resolved fluorescence spectroscopies have been used to probe the photophysical properties of ethidium bromide (Eb) complexed to calf thymus DNA (ct-DNA). Fluorescence decay profiles are obtained using the technique of time-correlated single photon counting (TCSPC), and subsequently analysed using conventional sum-of-exponential (SOE) routines and also the maximum entropy method (MEM). Through use of these methods and simulated decay data, it is demonstrated that the kinetics of Eb in the presence of ds-DNA are best described by a generic model consisting of three exponential terms. At all DNA:Eb ratios and NaCl concentrations studied, free Eb is detected. Furthermore, Eb is found to interact with ds-DNA through two mechanisms, each distinguishable by its fluorescence decay time. Eb is shown to interact with DNA through classic intercalation, and also through binding at secondary sites. The component decay times are shown to be a function of NaCl concentration but independent of DNA:Eb molar ratio.

Journal Article↗

Miniaturized total analysis systems for biological analysis.

This review article discusses and documents the basic philosophies, concepts and current advances in the field of micro-TAS development, with special emphasis on applications in the arena of biosciences. After a brief overview of miniaturization theory and fabrication techniques, areas of microfluidic component development, detection protocols, biochemical assays, and integrated biological analyses are addressed.

Biochemical Phenomena↗