Determination of the source position for the electron beams from a high-energy linear accelerator.

We have investigated the energy and field-size dependence of the source position of the electron beams from a Varian Clinac-2,500 accelerator. Three independent experimental methods were used: (1) multipinhole camera (MPC), (2) back projection of the full width at half maximum (FWHM), and (3) the inverse square law (ISL). The positions of the virtual and effective sources were calculated using the multiple Coulomb scattering (MCS) formalism. The results obtained from the MPC agree, within the experimental uncertainties, with the calculated values for the virtual source position. Similarly, the results from the FWHM method agree with the calculations with the exception of those for small field sizes at the lower energies. This is consistent with the fact that both kinds of measurements are not very sensitive to scattering in the photon and electron collimators. In contrast, the source position determined by the ISL method shows strong dependence on field size and energy, and does not agree with the values predicted by the MCS formalism. This is due to contamination from electrons scattered in the x ray and electron collimation system. The techniques and results reported here should be generally applicable to other scatter foil linear accelerators.

Electrons↗

Characteristic parameters of 6-22 MeV electron beams from a 25-MeV linear accelerator.

Depth-ionization measurements were performed using a thin wall parallel plate chamber in water at nominal electron energies of 6, 9, 12, 15, 18, and 22 MeV for the standard available square field sizes. The characteristic parameters of the central axis depth-dose distributions were derived and compared to corresponding values for other accelerators. Vacuum packed therapy-verification films were used in water to obtain isodose distributions in a plane containing the central axis of the beam. The uniformity index and penumbra of the beams were measured from isodose distributions obtained in planes perpendicular to the beam central axis, at depths of 1/2R85 in water.

Electrons↗

Preparation and evaluation of cosmetic patches containing lactic and glycolic acids.

BACKGROUND: Alpha-hydroxy acids such as glycolic acid (GA) and lactic acid (LA), are used in cosmetic patches. The important fact in cosmetic patches is its suitable adhesion and peel properties. AIM: The objective of this study was to prepare LA- and GA-containing cosmetic patches and evaluate in-vitro/in-vivo correlation of adhesion properties. METHODS: Pressure-sensitive adhesives with different concentrations of GA and LA were cast on a polyethylene terephthalate film. The patches were evaluated for peel adhesive strength. On the basis of in vitro adhesion properties the patches were selected for wear performance tests and skin irritation potential. RESULTS: The adhesion properties (adhesion to steel plate and skin) and cohesive strength tests indicated the substantial influence of GA and LA concentrations. Based on in vitro adhesion studies the patches containing 3% (w/w) GA were selected for in vivo studies. In vivo studies show that a formulation containing 3% GA displays good adhesion on the skin, but it leaves little residues on the skin. Skin Irritation studies on healthy human volunteers showed negligible erythema at the site of application after 48 h. CONCLUSION: The noninvasive patch test model was found useful for detecting irritant skin reactions to the cosmetic patch containing GA. Our results demonstrated a strong correlation between the adhesion to steel plate and adhesion to skin. But a weak correlation between the degree of adhesive residue on the skin in in vitro and in vivo tests was observed for the formulation containing 3% (w/w) GA.

Adhesiveness↗