PubMed Health⌕ Search

Biomedical subjects

A Jia

Publications and source records attributed to A Jia.

3 recordsLinked to original sources

Testing for linkage under robust genetic models.

Robust genetic models are used to assess linkage between a quantitative trait and genetic variation at a specific locus using allele-sharing data. Little is known about the relative performance of different possible significance tests under these models. Under the robust variance components model approach there are several alternatives: standard Wald and likelihood ratio tests, a quasilikelihood Wald test, and a Monte Carlo test. This paper reports on the relative performance (significance level and power) of the robust sibling pair test and the different alternatives under the robust variance components model. Simulations show that (1) for a fixed sample size of nuclear families, the variance components model approach is more powerful than the robust sibling pair approach; (2) when the number of nuclear families is at least approximately 100 and heritability at the trait locus is moderate to high (>0.20) all tests based on the variance components model are equally effective; (3) when the number of nuclear families is less than approximately 100 or heritability at the trait locus is low (<0. 20), on balance, the Monte Carlo test provides the best power and is the most valid. The different testing procedures are applied to determine which are able to detect the known association between low density lipoprotein cholesterol and the common genotypes at the locus encoding apolipoprotein E. Results from this application show that the robust sibling pair method may be more effective in practice than that indicated by simulations.

Alleles↗

[Fabrication and use of two kinds of overdenture attachments].

The authors introduced the fabrication of stud attachment and bar attachment used to increase the stability and retention of overdenture. During two years' periods, the results of the clinical practice indicated: the retention of overdenture was increased and patients' masticator function was improved when attachments were used, and then the fabrications of two kinds of attachments were simple and value of attachments is cheap. The technique was popularized and used easily.

Denture Precision Attachment↗

[Effect of stud attachment post design on dentin stress distribution].

The shape design of attachment post is crucial factors influencing post retention and stress distribution to the dentin. By means of CAD and FEA, the present study investigated the effects of the shape designs of attachment posts on the stress distribution in dentin. The results indicated that the taper post had wedging effects on the dentin and produced higher Von Misses stress than that of parallel side post and the Von Misses stress value of the dentin was about 1.1 times. The maximum Von Misses stress value that the design of the thread post produced was about 1.06 times the stress of the nonthread post did. However, the effects of post design on the dentin were minor compared with the bite force directions. In the same post design, the maximum Von Misses stress in dentin with 45 degree oblique force was about 2.1 times with vertical force. Therefore, reducing oblique force is the main method to prevent root fracture in clinic.

Computer-Aided Design↗