Investigation of a 2D two-point maximum entropy regularization method for signal-to-noise ratio enhancement: application to CT polymer gel dosimetry.

This study presents a new method of image signal-to-noise ratio (SNR) enhancement by utilizing a newly developed 2D two-point maximum entropy regularization method (TPMEM). When utilized as an image filter, it is shown that 2D TPMEM offers unsurpassed flexibility in its ability to balance the complementary requirements of image smoothness and fidelity. The technique is evaluated for use in the enhancement of x-ray computed tomography (CT) images of irradiated polymer gels used in radiation dosimetry. We utilize a range of statistical parameters (e.g. root-mean square error, correlation coefficient, error histograms, Fourier data) to characterize the performance of TPMEM applied to a series of synthetic images of varying initial SNR. These images are designed to mimic a range of dose intensity patterns that would occur in x-ray CT polymer gel radiation dosimetry. Analysis is extended to a CT image of a polymer gel dosimeter irradiated with a stereotactic radiation therapy dose distribution. Results indicate that TPMEM performs strikingly well on radiation dosimetry data, significantly enhancing the SNR of noise-corrupted images (SNR enhancement factors >15 are possible) while minimally distorting the original image detail (as shown by the error histograms and Fourier data). It is also noted that application of this new TPMEM filter is not restricted exclusively to x-ray CT polymer gel dosimetry image data but can in future be extended to a wide range of radiation dosimetry data.

Algorithms↗

Investigation of tetrakis hydroxymethyl phosphonium chloride as an antioxidant for use in x-ray computed tomography polyacrylamide gel dosimetry.

Of the antioxidants used to scavenge oxygen in polymer gel dosimeters, tetrakis (hydroxymethyl) phosphonium chloride (THPC) has been shown to hold great promise due to its rapid oxygen scavenging abilities. In this study we (a) investigate the use of THPC as an antioxidant for polyacrylamide gel (PAGAT) dosimeters used in conjunction with x-ray computed tomography (CT) and (b) work to establish the reaction mechanisms of THPC with the polymer gel constituents. We establish the dose response reproducibility of PAGAT dosimeters when imaged with CT and show that PAGAT dosimeters exhibit highly reproducible dose responses for a range of irradiation times post gel manufacture (2-6 h) and CT imaging times post gel irradiation (1-5 days). The THPC concentration within the gel leading to a maximized dose response and minimized O(2) inhibition of polymerization is found to be approximately 4.5 mM. We further assess the stability of PAGAT dosimeters by investigating the reactions of THPC with the individual gel constituents. The importance of utilizing deionized water in polymer gel manufacture is noted. We show that, while THPC remains unreactive with acrylamide and bis-acrylamide under unirradiated conditions, THPC can react with gelatin to increase the cross-linking of the gelatin matrix in unirradiated dosimeters. THPC reactions with gelatin can lead to the lower observed dose sensitivity of PAGAT (approximately 0.36 +/- 0.04 H Gy(-1)) as compared to polyacrylamide gels manufactured under anoxic conditions (approximately 0.83 +/- 0.03 H Gy(-1)). The reactions of THPC which lead to O(2) scavenging, and potential reactions of THPC with other gel constituents, are proposed.

Acrylic Resins↗

Technical considerations for implementation of x-ray CT polymer gel dosimetry.

Gel dosimetry is the most promising 3D dosimetry technique in current radiation therapy practice. X-ray CT has been shown to be a feasible method of reading out polymer gel dosimeters and, with the high accessibility of CT scanners to cancer hospitals, presents an exciting possibility for clinical implementation of gel dosimetry. In this study we report on technical considerations for implementation of x-ray CT polymer gel dosimetry. Specifically phantom design, CT imaging methods, imaging time requirements and gel dose response are investigated. Where possible, recommendations are made for optimizing parameters to enhance system performance. The dose resolution achievable with an optimized system is calculated given voxel size and imaging time constraints. Results are compared with MRI and optical CT polymer gel dosimetry results available in the literature.

Acrylic Resins↗

Effects of gel composition on the radiation induced density change in PAG polymer gel dosimeters: a model and experimental investigations.

Due to a density change that occurs in irradiated polyacrylamide gel (PAG), x-ray computed tomography (CT) has emerged as a feasible method of performing polymer gel dosimetry. However, applicability of the technique is currently limited by low sensitivity of the density change to dose. This work investigates the effect of PAG composition on the radiation induced density change and provides direction for future work in improving the sensitivity of CT polymer gel dosimetry. A model is developed that describes the PAG density change (delta(rho)gel) as a function of both polymer yield (%P) and an intrinsic density change, per unit polymer yield, that occurs on conversion of monomer to polymer (delta(rho)polymer). %P is a function of the fraction of monomer consumed and the weight fraction of monomer in the unirradiated gel (%T). Applying the model to experimental CT and Raman spectroscopic data, two important fundamental properties of the response of PAG density to dose (delta(rho)gel dose response) are discovered. The first property is that delta(rho)polymer)depends on PAG %C (cross-linking fraction of total monomer) such that low and high %C PAGs exhibit a higher deltarho(polymer)than do more intermediate %C PAGs. This relationship is opposite to the relationship of polymer yield to %C and is explained by the effect of %C on the type of polymer formed. The second property is that the delta(rho)gel dose response is linearly dependent on %T. From the model, the inference is that, at least for %T < or = 2%, monomer consumption and delta(rho)polymer depend solely on %C. In terms of optimizing CT polymer gel dosimetry for high sensitivity, these results indicate that delta(rho)polymer can be expected to vary with each polymer gel system and thus should be considered when choosing a polymer gel for CT gel dosimetry. However, delta(rho)polymerand %P cannot be maximized simultaneously and maximizing %P, by choosing gels with intermediate %C and high %T, is found to have the greatest impact on increasing the sensitivity of PAG density to dose. As such, future research into new gel formulations for high sensitivity CT polymer gel dosimetry should focus on gels that exhibit an intrinsic density change and maximizing polymer yield in these systems.

Acrylic Resins↗

Accuracy and precision of manual baseline determination.

Vibrational spectra often require baseline removal before further data analysis can be performed. Manual (i.e., user) baseline determination and removal is a common technique used to perform this operation. Currently, little data exists that details the accuracy and precision that can be expected with manual baseline removal techniques. This study addresses this current lack of data. One hundred spectra of varying signal-to-noise ratio (SNR), signal-to-baseline ratio (SBR), baseline slope, and spectral congestion were constructed and baselines were subtracted by 16 volunteers who were categorized as being either experienced or inexperienced in baseline determination. In total, 285 baseline determinations were performed. The general level of accuracy and precision that can be expected for manually determined baselines from spectra of varying SNR, SBR, baseline slope, and spectral congestion is established. Furthermore, the effects of user experience on the accuracy and precision of baseline determination is estimated. The interactions between the above factors in affecting the accuracy and precision of baseline determination is highlighted. Where possible, the functional relationships between accuracy, precision, and the given spectral characteristic are detailed. The results provide users of manual baseline determination useful guidelines in establishing limits of accuracy and precision when performing manual baseline determination, as well as highlighting conditions that confound the accuracy and precision of manual baseline determination.

Algorithms↗

Revealing system dynamics through decomposition of the perturbation domain in two-dimensional correlation spectroscopy.

A technique is presented to simply and effectively decompose the perturbation domain in two-dimensional (2D) correlation maps calculated on a given set of vibrational spectra. Decomposition of the perturbation domain exposes a wealth of kinetic information complementary to the information extracted from conventional 2D correlation spectroscopy. It is shown that the technique produces "perturbation profile maps" that can be utilized in both the interpretation of the conventional 2D correlation maps and the independent kinetic analysis of the given system. Discrimination between spectral features exhibiting similar, but not identical, dynamics is facilitated by the decomposition, and spectral features exhibiting identical dynamics over the perturbation interval are quickly identified. Spectral features exhibiting similar dynamics over only a sub-range of the full perturbation are also identifiable. Interpretation of phase information illuminated in synchronous and asynchronous maps is simplified. Comparison between similar spectral features present in different samples is facilitated with the technique. The simplicity and ease of implementation of the technique make decomposition of the perturbation domain a valuable addition to the tools available in 2D correlation analysis.

Journal Article↗

Identification and interpretation of generalized two-dimensional correlation spectroscopy features through decomposition of the perturbation domain.

Generalized two-dimensional correlation spectroscopy offers great scope for revealing the behavior of relationships between components of a system under empirical study. We have developed methods that aid in the interpretation of two-dimensional correlation spectroscopy. These methods include reference patterns for two-dimensional correlation and correlation coefficient maps, their superposition and joint interpretation, and the use of delta functions to decompose them in the perturbation domain. We show how their joint use permits discrimination between similar two-dimensional correlation map features on the basis of different correlation coefficients. We also show how the decomposition of maps into the perturbation domain reflects the dynamic behavior of spectral features over the course of the perturbation and permits discrimination between otherwise highly similar two-dimensional correlation cross-peaks. These approaches simplify the interpretation of two-dimensional correlation spectroscopy maps and facilitate access to their rich information content.

Journal Article↗

Relative effectiveness of polyacrylamide gel dosimeters applied to proton beams: Fourier transform Raman observations and track structure calculations.

The feasibility of using polyacrylamide gel (PAG) to characterize a clinically relevant 74 MeV proton beam has been considered. Fourier transform Raman spectroscopy has been used to measure the response (i.e., consumption of monomer) of PAG exposed to the central and end portions of a spread out Bragg peak (SOBP), i.e., in two regions with measurable difference in proton linear energy transfer (LET). The response curve in each region was compared with a typical 6 MV x-ray irradiated gel response curve, thus arriving at a gel "relative effectiveness" (RE) in each of the two regions. In addition, the theory of track structure, which is typically used to calculate a detector RE, is shown to give reasonable agreement when compared with the experimental results. Both experimental and track structure results indicate a decrease in gel response when irradiated with protons, as compared with the x-ray response. In addition, both sets of results indicate a variation in gel response between the mid and end SOBP regions, thus illuminating the dependence of gel response to proton LET. The physical phenomenon causing a lower proton versus x-ray gel response may be understood by considering the track structure calculations, which indicate that gel radiosensitive elements close to the track of a proton (i.e., within 1.5 x 10(-6) cm) are saturated. This saturation is due to the high delta-ray doses deposited in these regions. The track calculations are extended to other situations (e.g., raw BP, different gel compositions) where experimental determination of RE is difficult or time consuming. Results again indicate a gel response dependent on position in the depth dose curve (i.e., LET). Overall, this study illuminates the difficulty in using polyacrylamide gel to extract quantitative dose maps when exposed to proton radiation.

Acrylic Resins↗

CT gel dosimetry technique: comparison of a planned and measured 3D stereotactic dose volume.

This study presents a 3D dose mapping of complex dose distributions using an x-ray computed tomography (CT) polymer gel dosimetry technique. Two polyacrylamide gels (PAGs) of identical composition were irradiated with the same four arc stereotactic treatment to maximum doses of 15 Gy (PAG1) and 8 Gy (PAG2). The PAGs were CT imaged using a previously defined protocol that involves image averaging and background subtraction to improve image quality. For comparison with the planned isodose distribution, the PAG images were converted to relative dose maps using a CT number-dose calibration curve or simple division. The PAG images were then co-registered with the planning CT images in the BrainLab treatment planning software which automatically provides reconstructed sagittal and coronal images for 3D evaluation of measured and planned dose. The hypo-intense high dose region in both sets of gel images agreed with the planned 80% isodose contour and was shifted by up to 1.5 and 3.0 mm in the axial and reconstructed planes, respectively. This demonstrates the ability of the CT gel technique to accurately localize the high dose region produced by the stereotactic treatment. The resulting agreement of the measured relative dose volume for PAG1 was within 3.0 mm for the 50% and 80% isodose surfaces. However, the dose contrast was too low in PAG2 to allow for accurate definition of measured relative dose surfaces. Thus, a PAG should be irradiated to higher doses if quantitative relative dose information is required. Unfortunately, this implies use of an additional PAG and its CT number dose response since doses greater than 8-10 Gy fall outside the linear regions of the response.

Acrylamides↗

Polymer gel dosimetry using x-ray computed tomography: a feasibility study.

A new three-dimensional dosimetry technique using x-ray computed tomography (CT) to analyse polymer gels is proposed. The CT imaging is sensitive to radiation-induced density changes that occur within irradiated polyacrylamide gel (PAG). In this preliminary study, a CT imaging protocol is developed to optimize CT images of PAG; the response of PAG CT number to dose (N(CT)-dose response) and the reproducibility of the response are investigated, and the use of CT to analyse PAG is compared with MRI. Experiments were conducted using two 1.5 l cylindrical PAG phantoms (3% acrylamide, 3% bis and 5% gelatin by weight), one irradiated with four intersecting 10 MV photon beams and the other with 10 sets of 6 MV parallel opposed circular radiosurgery fields. The final imaging protocol involves using optimum CT parameters (120 kVp and 200 mAs for our GE HiSpeed CT/i scanner), image averaging and background subtraction. The N(CT)-dose response is reproducible, linear up to 800-1000 cGy and is relatively insensitive to the gel temperature during imaging. The dose resolution is approximately 50 cGy for an image thickness of 10 mm. Despite the low dose resolution, preliminary results indicate that this CT technique provides accurate localization of high dose gradients such as those observed in stereotactic radiosurgery. Thus, given the availability and speed of CT scanners, the technique has the potential to be a valuable and practical 3D dose verification tool in radiation therapy.

Acrylic Resins↗