PubMed HealthSearch

Biomedical subjects

A K Anderson

Publications and source records attributed to A K Anderson.

6 recordsLinked to original sources

Changes in cortical activity during mental rotation. A mapping study using functional MRI.

Mental imagery is an important cognitive method for problem solving, and the mental rotation of complex objects, as originally described by Shepard and Metzler (1971), is among the best studied mental imagery tasks. Functional MRI was used to observe focal changes in blood flow in the brains of 10 healthy volunteers performing a mental rotation task. On each trial, subjects viewed a pair of perspective drawings of three-dimensional shapes, mentally rotated one into congruence with the other, and then determined whether the two forms were identical or mirror-images. The control task, which we have called the 'comparison' condition, was identical except that both members of each pair appeared at the same orientation, and hence the same encoding, comparison and decision processes were used but mental rotation was not required. These tasks were interleaved with a baseline 'fixation' condition, in which the subjects viewed a crosshair. Technically adequate studies were obtained in eight of the 10 subjects. Areas of increased signal were identified according to sulcal landmarks and are described in terms of the Brodmann's area (BA) definitions that correspond according to the atlas of Talaraich and Tournoux. When the rotation task was contrasted with the comparison condition, all subjects showed consistent foci of activation in BAs 7a and 7b (sometimes spreading to BA 40): 88% had increased signal in middle frontal gyrus (BA 8) and 75% showed extrastriate activation, including particularly BAs 39 and 19, in a position consistent with area V5/human MT as localized by functional and histological assays. In more than half of the subjects, hand somatosensory cortex (3-1-2) was engaged, and in 50% of subjects there was elevated signal in BA 18. In frontal cortex, activation was above threshold in half the subjects in BAs 9 and/or 46 (dorsolateral prefrontal cortex). Some (four out of eight) subjects also showed signal increases in BAs 44 and/or 46. Premotor cortex (BA 6) was active in half of the subjects during the rotation task. There was little evidence for lateralization of the cortical activity or of engagement of motor cortex. These data are consistent with the hypothesis that mental rotation engages cortical areas involved in tracking moving objects and encoding spatial relations, as well as the more general understanding that mental imagery engages the same, or similar, neural imagery as direct perception.

Adult

Identifying objects seen from different viewpoints. A PET investigation.

Positron emission tomography scans were acquired when subjects performed three tasks, each in a separate block of trials. They decided whether words named pictures of objects viewed from a canonical perspective, decided whether words named pictures of objects viewed from a non-canonical (unusual) perspective or saw random patterns of lines and pressed a pedal when they heard the word (this was a baseline condition). The dorsolateral prefrontal region was activated when subjects identified objects seen from non-canonical perspectives, as expected if the frontal lobes are involved in top-down perceptual processing. In addition, several areas in the occipital, temporal and parietal lobes were selectively activated when subjects identified objects seen from non-canonical perspectives, as specifically predicted by a recent theory. Overall, the pattern of results supported the view that the human brain identifies objects by using a system of areas similar to that suggested by studies of other primates.

Adolescent

Percutaneous absorption of iodochlorhydroxyquin in humans.

Iodochlorhydroxyquin (I) is used in the treatment of diaper rash and other skin disorders, and is presumed to undergo little or no percutaneous absorption. The absorption of (I) from a 3% cream was studied in 5 normal male subjects after a single application of the cream for 12 h. Plasma levels of the drug were followed for 24 h after initial application while urinary excretion was measured for 54 h. (I) was extracted from plasma and urine and assayed by high-performance liquid chromatography. The drug in the range of 0.37-0.56 micrograms/ml was detected in plasma 2 h after application and persisted throughout the treatment period. The mean excretion rate after 12 h of application was 58.4 micrograms/h and the excretion rate was 8.8 micrograms/h at 42 h posttreatment. The elimination rate constant was calculated to be 0.15 h-1. Approximately 40% of the drug was absorbed over the 12-h application period. From the above results it is apparent that significant percutaneous absorption of (I) occurs.

Absorption

Stability of vitamin and mineral concentrations of a low-birth-weight infant formula during continuous enteral feeding.

The stability of several vitamins and minerals of a new formula for premature infants, Similac Special Care, was examined following passage through a simulated continuous infusion apparatus designed to duplicate that used for continuous enteral feeding in infants. The concentrations of calcium, iron, zinc, copper, magnesium, vitamin A, vitamin C, and vitamin E were measured before and after infusion at rates appropriate for delivering 120 calories/kg to infants weighing 733 and 1,000 g. Following passage through this apparatus, significant reductions were noted for calcium (44-54%), iron (23-34%), and zinc (18-32%). Concentrations of copper, magnesium, and vitamins A, C, and E remained stable. When another formula commonly used for premature infants, Similac 24LBW, was subjected to similar analysis, the concentrations of all vitamins and minerals studied remained stable. Our study demonstrates that infants fed Similac Special Care by continuous infusion may not receive the quantity of calcium, iron, and zinc implied by the product label.

Calcium