Examples of NIR based real time release in tablet manufacturing.

Real time release (RTR) of products is a new paradigm in the pharmaceutical industry. An RTR system assures that when the last manufacturing step is passed all the final release criteria are met. Various types of models can be used within the RTR framework. For each RTR system, the monitoring capability, control capability and RTR capability need to be tested. This paper presents some practical examples within the RTR framework using near-infrared and process data obtained from a tablet manufacturing process.

Chemistry, Pharmaceutical↗

Net analyte signal based statistical quality control.

Net analyte signal statistical quality control (NAS-SQC) is a new methodology to perform multivariate product quality monitoring based on the net analyte signal approach. The main advantage of NAS-SQC is that the systematic variation in the product due to the analyte (or property) of interest is separated from the remaining systematic variation due to all other compounds in the matrix. This enhances the ability to flag products out of statistical control. Using control charts, the analyte content, variation of other compounds, and residual variation can be monitored. As an example, NAS-SQC is used to appreciate the control content uniformity of a commercially available pharmaceutical tablet product measured with near-infrared spectroscopy. Using the NAS chart, the active pharmaceutical ingredient (API) content is easily monitored for new tablets. However, since quality is a multivariate property, other quality parameters of the tablets are also monitored simultaneously. It will be demonstrated that, besides the API content, the water content of the tablets as well as the homogeneity of the other compounds is monitored.

Chemistry Techniques, Analytical↗

Simple assessment of homogeneity in pharmaceutical mixing processes using a near-infrared reflectance probe and control charts.

Determination of homogeneous mixing of the active pharmaceutical ingredient (API) is an important in-process control within the manufacturing of solid dosage forms. In this paper two new near-infrared (NIR) based methods were presented; a qualitative and a quantitative method. Both methods are based on the calculation of net analyte signal (NAS) models which were very easy to develop, specific with respect to the API and required no additional reference analysis. Using a well-mixed batch as a 'golden standard' batch, control charts were developed and used for monitoring the homogeneity of other batches with NIR. The methods were fast, easy to use, non-destructive and provided statistical tests of homogeneity. A mixing study was characterized with the two methods and the methods were validated by comparison with traditional HPLC analysis.

Chemistry, Pharmaceutical↗

Classification of highly similar crude oils using data sets from comprehensive two-dimensional gas chromatography and multivariate techniques.

Comprehensive two-dimensional gas chromatography (GCxGC) has proven to be an extremely powerful separation technique for the analysis of complex volatile mixtures. This separation power can be used to discriminate between highly similar samples. In this article we will describe the use of GCxGC for the discrimination of crude oils from different reservoirs within one oil field. These highly complex chromatograms contain about 6000 individual, quantified components. Unfortunately, small differences in most of these 6000 components characterize the difference between these reservoirs. For this reason, multivariate-analysis (MVA) techniques are required for finding chemical profiles describing the differences between the reservoirs. Unfortunately, such methods cannot discern between 'informative variables', or peaks describing differences between samples, and 'uninformative variables', or peaks not describing relevant differences. For this reason, variable selection techniques are required. A selection based on information between duplicate measurements was used. With this information, 292 peaks were used for building a discrimination model. Validation was performed using the ratio of the sum of distances between groups and the sum of distances within groups. This step resulted in the detection of an outlier, which could be traced to a production problem, which could be explained retrospectively.

Chromatography, Gas↗

New indicator for optimal preprocessing and wavelength selection of near-infrared spectra.

Preprocessing of near-infrared spectra to remove unwanted, i.e., non-related spectral variation and selection of informative wavelengths is considered to be a crucial step prior to the construction of a quantitative calibration model. The standard methodology when comparing various preprocessing techniques and selecting different wavelengths is to compare prediction statistics computed with an independent set of data not used to make the actual calibration model. When the errors of reference value are large, no such values are available at all, or only a limited number of samples are available, other methods exist to evaluate the preprocessing method and wavelength selection. In this work we present a new indicator (SE) that only requires blank sample spectra, i.e., spectra of samples that are mixtures of the interfering constituents (everything except the analyte), a pure analyte spectrum, or alternatively, a sample spectrum where the analyte is present. The indicator is based on computing the net analyte signal of the analyte and the total error, i.e., instrumental noise and bias. By comparing the indicator values when different preprocessing techniques and wavelength selections are applied to the spectra, the optimal preprocessing technique and the optimal wavelength selection can be determined without knowledge of reference values, i.e., it minimizes the non-related spectral variation. The SE indicator is compared to two other indicators that also use net analyte signal computations. To demonstrate the feasibility of the SE indicator, two near-infrared spectral data sets from the pharmaceutical industry were used, i.e., diffuse reflectance spectra of powder samples and transmission spectra of tablets. Especially in pharmaceutical spectroscopic applications, it is expected beforehand that the non-related spectral variation is rather large and it is important to remove it. The indicator gave excellent results with respect to wavelength selection and optimal preprocessing. The SE indicator performs better than the two other indicators, and it is also applicable to other situations where the Beer-Lambert law is valid.

Calibration↗

Multiblock PLS analysis of an industrial pharmaceutical process.

The performance of an industrial pharmaceutical process (production of an active pharmaceutical ingredient by fermentation, API) was modeled by multiblock partial least squares (MBPLS). The most important process stages are inoculum production and API production fermentation. Thirty batches (runs) were produced according to an experimental planning. Rather than merging all these data into a single block of independent variables (as in ordinary PLS), four data blocks were used separately (manipulated and quality variables for each process stage). With the multiblock approach it was possible to calculate weights and scores for each independent block. It was found that the inoculum quality variables were highly correlated with API production for nominal fermentations. For the nonnominal fermentations, the manipulations of the fermentation stage explained the amount of API obtained (especially the pH and biomass concentration). Based on the above process analysis it was possible to select a smaller set of variables with which a new model was built. The amount of variance predicted of the final API concentration (cross-validation) for this model was 82.4%. The advantage of the multiblock model over the standard PLS model is that the contributions of the two main process stages to the API volumetric productivity were determined.

Bioreactors↗

A multiway 3D QSAR analysis of a series of (S)-N-[(1-ethyl-2-pyrrolidinyl)methyl]-6-methoxybenzamides.

Recently, the multilinear PLS algorithm was presented by Bro and later implemented as a regression method in 3D QSAR by Nilsson et al. In the present article a well-known set of (S)-N-[(1-ethyl-2-pyrrolidinyl)methyl]-6-methoxybenzamides, with affinity towards the dopamine D2 receptor subtype, was utilised for the validation of the multilinear PLS method. After exhaustive conformational analyses on the ligands, the active analogue approach was employed to align them in their presumed pharmacologically active conformations, using (-)-piquindone as a template. Descriptors were then generated in the GRID program, and 40 calibration compounds and 18 test compounds were selected by means of a principal component analysis in the descriptor space. The final model was validated with different types of cross-validation experiments, e.g. leave-one-out, leave-three-out and leave-five-out. The cross-validated Q2 was 62% for all experiments, confirming the stability of the model. The prediction of the test set with a predicted Q2 of 62% also established the predictive ability. Finally, the conformations and the alignment of the ligands in combination with multilinear PLS, obviously, played an important role for the success of our model.

Algorithms↗

Liquid chromatographic analysis of carboxylic acids using N-(4-aminobutyl)-N-ethylisoluminol as chemiluminescent label: determination of ibuprofen in saliva.

N-(4-Aminobutyl)-N-ethylisoluminol was used for labelling of carboxylic acids. The derivatization reaction was carried out with 1-hydroxybenzotriazole as pre-activator of the carboxylic acid function and N-ethyl-N'-(3-dimethylaminopropyl)carbodiimide as the coupling reagent. Optimum conditions for the derivatization were determined by using factorial design analysis, with ibuprofen as the test compound. Chemiluminescence detection was carried out using a post-column on-line electrochemical hydrogen peroxide generation system and the addition of microperoxidase as the catalyst. The detection limit of derivatized ibuprofen in human saliva was 0.7 ng per 0.5 ml of saliva, with a recovery of 96.1 +/- 1.3%. The method was linear over at least three decades (2.5 ng to 2.5 micrograms) and the repeatability was satisfactory (R.S.D. = 5.2% at the 25 ng level; n = 4).

Blood Proteins↗

Optimization of the reversed-phase high-performance liquid chromatographic separation of synthetic estrogenic and progestogenic steroids using the multi-criteria decision making method.

The optimization of the reversed-phase high-performance liquid chromatographic separation of a mixture of ethynylestradiol, desogestrel and three related compounds is described. A procedure is used that allows the prediction of the capacity factors of each individual synthetic steroid, depending on the mobile phase composition. Therefore, complete chromatograms can be predicted and evaluated with the multi-criteria decision making method.