2D and 3D dose distribution determination in proton beam radiotherapy with GafChromic film detectors.

This paper presents the results obtained using radiochromic (MD-55 GafChromic) film for the 2D and 3D dosimetric reconstruction of the dose delivered by a proton beam under the real conditions of a programme of radiotherapy treatment for ocular tumours. Standard microdensitometric measurements were used to determine the variation in film optical density (O.D.) vs dose. Calibration curves were obtained by least-square fitting of the experimental OD values using a second order polynomial. This allows conversion of O.D. to dose. With this procedure it was possible to determine the distribution of the dose delivered by the proton beam in a phantom composed of layers of GafChromic film, with high surface spatial resolution and, through sections, the complete mapping of the dose delivered to a volume subjected to irradiation, as in a course of radiotherapy treatment.

Eye Neoplasms↗

Proton dosimetry comparison involving ionometry and calorimetry.

A comparison of the absorbed dose to tissue determined by various ionization chambers, Faraday cups, and an A-150 plastic calorimeter was performed in the 200 MeV proton beam of Orsay, France. Four European proton-therapy centers (Clatterbridge, UK, Louvain la Neuve, Belgium, and Nice and Orsay, France) participated in the comparison. An agreement of better than 1% was observed in the absorbed dose to A-150 measured with the different chambers of the participating groups. The mean ratio of the absorbed dose to A-150 determined with the calorimeter to that determined by the different ionization chambers in the different irradiation conditions was found to be 0.952 +/- 0.007 [1 standard deviation (SD)] according to the code of practice used by all the participating centers, based on Janni's tables of stopping powers and a value of 35.2 J/Coulomb for (W(air)/e)p. A better agreement in the mean ratio calorimeter/chamber, 0.985 +/- 0.007 (1 SD) is observed when using the proton stopping power ratio values recently published by the International Commission on Radiation Units and Measurements in Report no. 49. The mean ratio of these doses determined in accordance with the American Association of Physicists in Medicine protocol and using the new recommended stopping power tables becomes 1.002 +/- 0.007 (1 SD). Two Faraday cups agree in measured charge to within 0.8%; however, the calculation of dose is underestimated by up to 17%; compared with ion chamber measurements and seems to be very sensitive to measurement conditions, particularly to the distance to the collimator.

Calibration↗

Predictive factors for the development of rubeosis following proton beam radiotherapy for uveal melanoma.

AIMS/BACKGROUND: Proton beam radiotherapy can effectively treat primary uveal melanomas of any size. Some patients, however, develop adverse late effects following treatment and the purpose of this study was to determine which factors give rise to a poor local outcome. METHODS: The hospital records from a first cohort of 127 patients treated by protons from 1989 to 1992 were reviewed retrospectively. The presence of rubeosis was selected as a measure of significant ocular damage. Split file analysis was performed with 73 cases forming a test group with the remaining 54 cases acting as a validation group. RESULTS: Large tumour size and the presence of retinal detachment were significant, independent risk factors for developing rubeosis for both the test and validation groups. These factors also predicted subsequent enucleation for uncontrolled ocular pain. Patients with tumours too large to plaque and with an associated retinal detachment had a 90% chance of developing rubeosis within 4 years of proton beam radiotherapy. CONCLUSIONS: Patients with a uveal melanoma too large for plaque therapy and an associated retinal detachment run a very high risk of developing rubeosis after proton beam radiotherapy and one third of individuals developing rubeosis required enucleation for pain even if local tumour control was satisfactory.

Adult↗

Proton dosimetry intercomparison.

BACKGROUND AND PURPOSE: Methods for determining absorbed dose in clinical proton beams are based on dosimetry protocols provided by the AAPM and the ECHED. Both groups recommend the use of air-filled ionization chambers calibrated in terms of exposure or air kerma in a 60Co beam when a calorimeter or Faraday cup dosimeter is not available. The set of input data used in the AAPM and the ECHED protocols, especially proton stopping powers and w-value is different. In order to verify inter-institutional uniformity of proton beam calibration, the AAPM and the ECHED recommend periodic dosimetry intercomparisons. In this paper we report the results of an international proton dosimetry intercomparison which was held at Loma Linda University Medical Center. The goal of the intercomparison was two-fold: first, to estimate the consistency of absorbed dose delivered to patients among the participating facilities, and second, to evaluate the differences in absorbed dose determination due to differences in 60Co-based ionization chamber calibration protocols. MATERIALS AND METHODS: Thirteen institutions participated in an international proton dosimetry intercomparison. The measurements were performed in a 15-cm square field at a depth of 10 cm in both an unmodulated beam (nominal accelerator energy of 250 MeV) and a 6-cm modulated beam (nominal accelerator energy of 155 MeV), and also in a circular field of diameter 2.6 cm at a depth of 1.14 cm in a beam with 2.4 cm modulation (nominal accelerator energy of 100 MeV). RESULTS: The results of the intercomparison have shown that using ionization chambers with 60Co calibration factors traceable to standard laboratories, and institution-specific conversion factors and dose protocols, the absorbed dose specified to the patient would fall within 3% of the mean value. A single measurement using an ionization chamber with a proton chamber factor determined with a Faraday cup calibration differed from the mean by 8%. CONCLUSION: The adoption of a single ionization chamber dosimetry protocol and uniform conversion factors will establish agreement on proton absorbed dose to approximately 1.5%, consistent with that which has been observed in high-energy photon and electron dosimetry.

Calibration↗

Proton beams.

Explore the source record for details and available documents.

Humans↗

The measurement of silicon in a lung phantom--a comparison of two nuclear reactions for in vivo activation analysis.

The amount of silica in the human lung may be estimated by measurement of silicon using in vivo neutron activation analysis. A pulsed, fast neutron beam, produced with a 2 MV Van de Graaff generator using the 2H + 2H reaction, was used to irradiate a Si-doped chest phantom in order to determine minimum detection limits (MDL). Two 'in-beam' nuclear reactions on Si were studied; prompt fast neutron inelastic scatter 28Si (n,n' gamma)28Si reaction was measured during the beam burst and the slow neutron prompt capture reaction was measured between the fast neutron bursts. Although the latter reaction appeared less favourable due to neutron cross section and measurement efficiency considerations, it yielded an MDL of 1.8 g compared with 2.3 g for the 28Si(n,n' gamma)28Si reaction. A comparison was made with a 252Cf neutron irradiation system where a Si MDL of 6.3 g was obtained using the slow neutron capture reaction. The Van de Graaff system permits 'exposed' Si lung burdens to be measured but not normal levels. Improved measurement sensitivity may be achieved by reduction of high counting-rate losses and high background radiation.

Humans↗

The 62 MeV proton beam for the treatment of ocular melanoma at Clatterbridge.

A second treatment room and beam line has been constructed at the Cyclotron Unit at Clatterbridge for the purpose of using 62 MeV protons for the treatment of ocular melanoma. A uniform beam is produced by a double foil scattering system. The initial Bragg peak is spread across the target volume by the use of beam modulators. These are rotating four-vaned stepped absorbers made from Perspex. Two beam lines can be configured with different positions of modulators and range limiters. The first has a maximum penetration of 31.9 +/- 0.2 mm in water and the second a penetration of 31.2 +/- 0.2 mm. The second configuration has the advantage of less variation in beam penumbra, with a typical value of 1.7 +/- 0.1 mm for the 90% to 10% decrement lines. The patients are treated with individually shaped collimators. Beam output varies by less than 2% over the range of collimator areas used. The resulting whole-body dose equivalent to patient has also been assessed. In the first three years of operation over 250 patients have been treated.

Eye Neoplasms↗