PubMed Health⌕ Search

Biomedical subjects

A Kayikçioğlu

Publications and source records attributed to A Kayikçioğlu.

At least 19 recordsLinked to original sources

A new flap model in rats: iliac osteomusculocutaneous flap.

Although osteomusculocutaneous flaps are used frequently in clinical practice to repair defects involving soft tissue and bone, there are still many questions that remain to be answered regarding their basic physiology. To accomplish such basic science studies, simple and reliable animal osteomusculocutaneous flap models are needed. The purpose of this study was to describe a new flap model in rats--namely, the iliac osteomusculocutaneous flap. Thirty adult Wistar rats weighing 200 to 250 g were used in this experiment. In 15 rats, the vascular anatomy of the iliolumbar vessels and their relation with adjacent soft tissues and the iliac bone was determined by anatomic dissection. Based on this anatomic study, the iliac osteomusculocutaneous flap model was created in rats. The flap is comprised of a skin island (3 x 3 cm) in the flank region, a 1 x 1-cm segment of iliac bone, and an abdominal wall muscle cuff. In 10 rats, the flap was raised as an island flap based on its vascular pedicle of iliolumbar vessels, and was replaced in situ. In the remaining 5 rats, the flap was transferred to the groin region as a free flap. Direct observation on postoperative day 7 revealed that the skin island of all the flaps was completely viable. Bone scintigraphy performed on postoperative day 3 in free flaps demonstrated radionuclide uptake, indicating viability of the bony segment. The dye injection study revealed ink staining within blood vessels of the bone, confirming its viability. Microangiography of the flap demonstrated vascularity of each component of the flap by the iliolumbar vessels, including a distinct branch to the iliac bone. The authors conclude that the iliac osteomusculocutaneous flap of the rat is a simple and reliable flap model that offers the following advantages: (1) It is a true osteomusculocutaneous flap, (2) it can be used as a free flap without the need for an isogeneic rat, (3) the vascular pedicle is consistent, and (4) it is harvested from a small-animal species.

Abdominal Muscles↗

Long-term effects of extraluminal dilatation with a rigid circle on arteriovenous anastomotic line in venous grafts transposed into arterial defects.

Postanastomotic narrowing resulting from subintimal hyperplasia is a well-known phenomenon. In the current study the authors compared a metallic circle and conventional suture technique in anastomoses performed in two ends of external jugular vein grafts interposed in carotid arteries of rabbits. They recorded the patency rates, fluid flow rates, and histological effects of the circle on the anastomotic line and compared them with conventional suture anastomoses. In 16 rabbits (experimental group) a standard suture was used in both ends of the jugular vein graft transposed to the carotid arteries on one side. On the other side, circle anastomoses were performed on both ends of the vein graft. In an additional 8 rabbits (control group), the anterior jugular veins and carotid arteries were dissected on both sides and left. During postoperative week 12, in 8 rabbits of the experimental group, the flow rates of carotid arteries were measured in vitro, and intraluminal silicone casts were prepared. In the remaining 8 experimental rabbits, carotid angiographies were performed and anastomotic segments were harvested for histological examination. Flow rates were also measured in the control group, and artery and vein segments were harvested. The patency rates of the vein grafts with metallic circle anastomoses were 100%, whereas conventional suture patency was 75% at week 12. Flow rates were significantly higher in the metallic circle-anastomosed vein grafts (74 ml per minute vs. 123 ml per minute, mean values; p < 0.05). Histological examination revealed reduced intimal thickness in the metallic circle anastomoses compared with conventional suture anastomoses. Dilatation of the arteriovenous end-to-end anastomotic line by a rigid circle prevents anastomotic narrowing in the long term.

Anastomosis, Surgical↗

End-to-side microvascular anastomosis using an external metal ring.

Enthusiasm for developing safer and faster anastomotic techniques and complementary devices continues. We report on a new microvascular end-to-side anastomosis technique using a silver ring around the anastomotic circumference. The purpose of this study was to compare the effectiveness of this technique with conventional end-to-side vessel anastomosis. Forty Sprague-Dawley rats were divided into two groups. Twenty rats were used to assess the external ring method in end-to-side anastomosis between carotid arteries and anterior jugular veins and the remaining 20 formed the control group with conventional end-to-end anastomosis. The anastomosis time was 26.4 min for standard suture anastomosis and 18.4 min for the external ring technique (P< 0.01). Patency was 95% with standard technique and 100% using the external ring (P> 0.05). The external ring technique of end-to-side microvascular anastomosis is a safe and reliable method and may reduce the operation time. Its clinical applicability should be further evaluated.

Anastomosis, Surgical↗

Comparison of immune response to nerve allograft segments in fetal and adult rabbits: a histological study.

Fetuses, as opposed to adults, are immature immunologically and it has been proved that they can tolerate allograft materials much better than adults. In this study the rejection phenomenon of nerve allografts was compared histologically in fetuses and adults. The study was performed in 60 New Zealand rabbits (30 pregnant and 30 nonpregnant), and allograft nerve segments were obtained from Chinchilla rabbits. The animals were divided into fetal and adult groups. Each group was studied at various time periods. Nerve allografts were placed under the panniculus carnosus in the interscapular region of the fetuses and adults. In both fetal and adult groups, the nerve allograft segments were assessed histologically after 1, 7, and 30 days. The criteria used during the evaluation were the degenerative findings in the myelinated axons (large, medium, and small axons), changes in Schwann's cells, and the quantity of infiltrating cells. The changes were graded microscopically from 0 (no change) to 3 (severe destruction and cellular infiltration). Cellular infiltration was more extensive in the adult groups than in the fetal groups. Earlier fetal groups showed minimal infiltration, but the response became more extensive in the later fetal groups. This is probably related to the removal of the fetuses from their intrauterine environment. When comparing fetal and adult groups, the results were significant (p < 0.05). The fetuses tolerated the nerve allograft segments better than the adults. This may be related to the immature immune system of the fetuses.

Animals↗

Two new intramedullary implant designs for phalanx fixation in digital replantation: an experimental study.

Bone fixation in digital replantation must provide adequate rigidity, and must be applied in a fast and easy manner. Various fixation methods have been used so far with certain advantages and disadvantages. The authors report two new intramedullary proximal phalangeal implant designs to secure two amputated bone segments tightly. They compare their intramedullary implants with commonly applied K-wire fixation methods and plate fixation via biomechanical analysis in terms of bending rigidity and distraction strength. Their two-sided asymmetrical screw provided the highest rigidity and distraction strength, whereas the hook-trap system was nearly equal to cross-K-wire fixation. Intramedullary bone fixation may be a feasible method of bone fixation, and resorbable implant materials and different implant configurations deserve further investigation.

Amputation, Traumatic↗

End-to-side neurorrhaphies of the ulnar and median nerves at the wrist: report of two cases without sensory or motor improvement.

The authors present two unsuccessful clinical cases of end-to-side neurorrhaphy. In the first patient the distal median nerve was coapted in an end-to-side manner to the intact ulnar nerve. In the other patient four cables of sural nerve graft were used to bridge the ulnar nerve and the intact median nerve by two end-to-side coaptations. Neurorrhaphies were performed via epineural sutures through epineural windows. Both of the cases failed to demonstrate any signs of regeneration either clinically or as evidenced by electromyography, Semmes-Weinstein monofilament test, or 256-Hz vibration tests at 18 and 21 months' follow-up respectively.

Adult↗

Lymphatic malformation causing intractable chylorrhagia.

Lymphatic malformation is a developmental error usually noticed at birth or in early childhood. Lesions of the upper leg and lower trunk are the most difficult to remove, because they are often the largest ones encountered and also because they tend to extend proximally into the retroperitoneal tissues. Chyle reflux, usually associated with lymphedema of the extremity, has not been reported to be caused by lymphatic malformation. We report a case of intrapelvic retroperitoneal lymphatic malformation with an extension of gluteal-thigh soft-tissue involvement causing intractable chylorrhagia. The tumor was subtotally excised, and the defect was closed by a distally based, peninsular latissimus dorsi myocutaneous flap. The flap served both as a filling material and as a "bridge" between the residual tumor, including abnormal lymphatics, and normal lymph flow.

Adolescent↗

Crossover replantation and fillet flap coverage of the stump after ectopic implantation: a case of bilateral leg amputation.

A successful case of crossover replantation of the left foot to the stump of the right leg and temporary ectopic implantation of the right amputated foot on the forearm is described. The ectopically implanted right foot was used as a free fillet flap for the late reconstruction of the left leg stump. At the latest follow-up examination, 18 months after the accident, the patient was able to walk independently with a prosthesis on the stump of the left leg. Both the cross-replanted foot and the free filleted foot flap, used for the reconstruction of the left leg stump, have maintained adequate protective sensation. The importance of utilization of amputated parts for functional reconstruction is stressed. Crossover replantations and ectopic implantations should be considered in bilateral amputations for the salvage of at least one extremity.

Adolescent↗

Intrasphenoidal migration of a premaxillary Kirschner wire.

OBJECTIVE: The use of Kirschner wire for the fixation of premaxilla is a well-known method in bilateral cleft lip surgery. We report a case in which the Kirschner wire of the premaxillary fixation had migrated intrasphenoidally. RESULTS AND CONCLUSIONS: The foreign body was accidentally discovered during a cephalometric analysis and was taken out surgically through an upper lip sulcus incision. Although the wire remained asymptomatic for 10 years, it constituted a potential danger for intracranial migration.

Child↗