PubMed Health⌕ Search

Biomedical subjects

A Khamene

Publications and source records attributed to A Khamene.

3 recordsLinked to original sources

[A head-mounted display system for augmented reality: initial evaluation for interventional MRI].

PURPOSE: To discuss the technical details of a head mounted display with an augmented reality (AR) system and to describe a first pre-clinical evaluation in interventional MRI. METHOD: The AR system consists of a video-see-through head mounted display (HMD), mounted with a mini video camera for tracking and a stereo pair of mini cameras that capture live images of the scene. The live video view of the phantom/patient is augmented with graphical representations of anatomical structures from MRI image data and is displayed on the HMD. The application of the AR system with interventional MRI was tested using a MRI data set of the head and a head phantom. RESULTS: The HMD enables the user to move around and observe the scene dynamically from various viewpoints. Within a short time the natural hand-eye coordination can easily be adapted to the slightly different view. The 3D perception is based on stereo and kinetic depth cues. A circular target with a diameter of 0.5 square centimeter was hit in 19 of 20 attempts. In a first evaluation the MRI image data augmented reality scene of a head phantom allowed good planning and precise simulation of a puncture. CONCLUSION: The HMD in combination with AR provides a direct, intuitive guidance for interventional MR procedures.

Computer Graphics↗

A spectral-discrimination method for tear-film lipid-layer thickness estimation from fringe pattern images.

Examination of the tear-film lipid layer is often helpful in the prognosis of prospective contact lens patients and contact lens related problems, and in the analysis of symptomatic noncontact lens-wearing patients. In particular, the thickness of the lipid layer is considered to be an informative cue in studying the tear-film stability and uncovering of certain disorders. We propose a method for the accurate estimation of the lipid-layer thickness, exploiting the intensity and color information in Fizeau fringe images. The technique is based on a quantitative measure for discriminating among the spectra associated with different thicknesses. We propose an optical system for imaging the interference patterns, develop a mathematical model based on the physics of the fringe formation and sensing, and describe the calibration of the optical system using this model. The thickness extraction is readily carried out utilizing a lookup table. The proposed method would enable objective evaluation of the lipid layer characteristics, and provide a means for examining the dynamic changes in its thickness and spatial distribution during inter-blink periods.

Algorithms↗

A new method for the extraction of fetal ECG from the composite abdominal signal.

We developed a wavelet transform-based method to extract the fetal electrocardiogram (ECG) from the composite abdominal signal. This is based on the detection of the singularities obtained from the composite abdominal signal, using the modulus maxima in the wavelet domain. Modulus maxima locations of the abdominal signal are used to discriminate between maternal and fetal ECG signals. Two different approaches have been considered. In the first approach, at least one thoracic signal is used as the a prior to perform the classification whereas in the second approach no thoracic signal is needed. A reconstruction method is utilized to obtain the fetal ECG signal from the detected fetal modulus maxima. The proposed technique is different from the classical time-domain methods, in that we exploit the most distinct features of the signal, leading to more robustness with respect to signal perturbations. Results of experiments with both synthetic and real ECG data have been presented to demonstrate the efficacy of the proposed method.

Abdomen↗