PubMed HealthSearch

Biomedical subjects

A Kohlrausch

Publications and source records attributed to A Kohlrausch.

14 recordsLinked to original sources

Pitch related to spectral edges of broadband signals.

A complex tone often evokes a pitch sensation associated with its extreme spectral components, besides the holistic pitch associated with its fundamental frequency. We studied the edge pitch created at the upper spectral edge of complexes with a low-pass spectrum by asking subjects to adjust the frequency of a sinusoidal comparison tone to the perceived pitch. Measurements were performed for different values of the fundamental frequency and of the upper frequency of the complex as well as for three different phase relations of the harmonic components. For a wide range of these parameters the subjects could adjust the comparison tone with a high accuracy, measured as the standard deviation of repeated adjustments, to a frequency close to the nominal edge frequency. The detailed dependence of the matching accuracy on temporal parameters of the harmonic complexes suggests that the perception of the edge pitch in harmonic signals is related to the temporal resolution of the hearing system. This resolution depends primarily on the time constants of basilar-membrane filters and on additional limitations due to neuronal processes.

Acoustic Stimulation

Spectral integration of broadband signals in diotic and dichotic masking experiments.

The method of Gässler [Acustica 4, 408-414 (1954)] was used to measure the audibility of multicomponent signals as a function of their bandwidth against a broadband, white-noise masker. Test signals were composed of 1 to 41 sinusoids with a spectral spacing of 10 Hz and were always spectrally centered around 400 Hz. Masker duration was 400 ms and the 300-ms signals were centered within the noise intervals. A three-interval forced-choice procedure with adaptive level adjustment was applied. NoSo, NoSm, NoS pi, and N pi So masked thresholds were obtained for four subjects. A comparison of the diotic and the three dichotic conditions yields no significant difference in the bandwidth dependence and suggests equal integration bandwidths for all conditions. However, the original results of Gässler could not be replicated: Neither were the overall levels of signals with a bandwidth below the critical bandwidth constant nor were the results for broadband signals in accordance with a single-band model of detection. The narrow-band data are much better described by calculating the overall signal level at the output of a rounded exponential filter [Patterson et al., J. Acoust. Soc. Am. 72, 1788-1803 (1982)] with an equivalent rectangular bandwidth of 65 Hz. For broader signal bandwidths, the signal level at threshold increases as predicted by a multiband model.

Acoustics

Differences in auditory performance between monaural and dichotic conditions. I: masking thresholds in frozen noise.

Thresholds of a 5-ms, 1-kHz signal were determined in the presence of a frozen-noise masker. The noise had a flat power spectrum between 20 Hz and 5 kHz and was presented with a duration of 300 ms. The following interaural conditions were tested with four listeners: Noise and signal monaural at the same ear (monaural condition, NmSm), noise and signal identical at both ears (diotic condition, NoSo), noise identical at both ears and signal monaural (dichotic condition, NoSm) and uncorrelated noise at the two ears and signal monaural (NuSm). The signal was presented at a fixed temporal position with respect to the frozen noise in all measurements and thresholds were determined for different starting phases of the carrier frequency of the signal. Variation of the carrier phase strongly influenced the detection in the diotic condition and the masked thresholds varied by more than 10 dB. The pattern of thresholds for the monaural condition was less variable and the thresholds were generally higher than for the diotic condition. The monaural-diotic difference for specific starting phases amounted to as much as 8 dB. Comparison measurements using running noise maskers revealed no such difference. This relation between monaural and diotic thresholds was further investigated with eight additional subjects. Again, monaural and diotic thresholds in running noise were identical, while in frozen noise, diotic thresholds were consistently lower than monaural thresholds, even when the ear with the lower NmSm threshold was compared. For the starting phase showing the largest monaural-diotic difference, the thresholds for NoSm lay between the monaural and the diotic values. At other starting phases, the NoSm threshold was clearly lower than both the NmSm and the NoSo threshold. One possible explanation of the observed monaural-diotic differences relates to contralateral efferent interaction between the right and the left hearing pathway. A prediction based on this explanation was verified in a final experiment, where frozen-noise performance for NmSm was improved by simultaneously presenting an uncorrelated running noise to the opposite ear.

Acoustic Stimulation

Binaural masking experiments using noise maskers with frequency-dependent interaural phase differences. I: Influence of signal and masker duration.

In this paper previous experiments on auditory filter shapes in binaural masking experiments [A. Kohlrausch, J. Acoust. Soc. Am. 84, 573-583 (1988)] are extended to a wider range of masker and signal durations. The masker was a dichotic broadband noise with frequency-dependent interaural parameters. The interaural phase difference of the masker was 0 below 500 Hz and pi above 500 Hz. Signal frequency varied between 200 and 800 Hz, and the signal was presented either monaurally (Sm) or binaurally in antiphase (S pi). In the first experiment, the masker duration was fixed at 500 ms and signals of 250 and 20 ms were used. In the second experiment, the signal duration was fixed at 20 ms, and the masker duration was reduced to 25 ms. The results from both experiments are consistent with studies using No or N pi maskers: The binaural masking level difference (BMLD) increases slightly for shorter test signals and decreases strongly for short maskers. The BMLD patterns of the first experiment are well described by the auditory-filter model derived for stationary test signals, if the additional influence of "off-frequency listening" for the short test signal is taken into account. The BMLDs resulting from the second experiment (25-ms masker), however, are much lower than predicted by this filter model This outcome supports previous observations that binaural unmasking becomes less effective for very short masker durations and indicates that this effect is even stronger for maskers with a complex structure of interaural parameters.

Attention

Binaural masking experiments using noise maskers with frequency-dependent interaural phase differences. II: Influence of frequency and interaural-phase uncertainty.

This study investigates whether binaural signal detection is improved by the listener's previous knowledge about the interaural phase relations of masker and test signal. Binaural masked thresholds were measured for a 500-ms dichotic noise masker that had an interaural phase difference of 0 below 500 Hz and of pi above 500 Hz. The thresholds for two difference 20-ms test signals were determined within the same measurement using an interleaved adaptive 3-interval forced-choice (3IFC) procedure. In each 3IFC trial, both signals could occur with equal probability (uncertainty). The two signals differed in frequency and interaural phase in such a way that one signal always had a frequency above the masker edge frequency (500 Hz) and no interaural phase difference (So), whereas the other signal frequency was below 500 Hz and the interaural phase difference was pi (S pi). The frequencies of a signal pair remained fixed during the whole 3IFC track. These two signals thus lead to two different binaural conditions, i.e., NoS pi for the low-frequency signal and N pi So for the high-frequency signal. For comparison, binaural masked thresholds were measured with the same masker for fixed signal frequency and phase. The binaural masking level differences (BMLDs) resulting from the two experimental conditions show no significant difference. This indicates that the binaural system is able to apply different internal transformations or processing strategies simultaneously in different critical bands and even within the same critical band.

Attention

Auditory filter shape derived from binaural masking experiments.

The shape of the auditory filter was calculated from binaural masking experiments. Two different types of maskers were used in the study, a masker that was interaurally in phase at all frequencies (No), and a masker with an interaural phase difference of 0 below 500 Hz and of pi above 500 Hz. The test-signal frequency varied between 200 and 800 Hz, and the test signal was presented either monaurally (Sm) or binaurally in antiphase (S pi). By comparing the masked thresholds from the two experimental conditions, the following conclusion can be drawn: The threshold of the test signal is only affected by the masker phase within a narrow frequency range around the test frequency. Thus, for test-signal frequencies well above or below 500 Hz, no influence of the phase transition on the BMLD is observed, and normal masked thresholds for No and N pi maskers are obtained. For test frequencies around 500 Hz, the step in interaural phase difference leads to a decrease in the interaural correlation of the masker within the critical band around the test-signal frequency. This results in strong threshold changes for both monaural and binaural signals. A calculation of the auditory filter shape from the masked threshold values was performed under the assumption that the masked threshold is only dependent on the interaural cross correlation of the masker within the filter band. Using the formula of the EC theory for the relation between masker correlation and BMLD, the experimental data are well described by a trapezoidal filter with an equivalent rectangular bandwidth of 80 to 84 Hz.

Adult

The influence of signal duration, signal frequency and masker duration on binaural masking level differences.

Binaural masked thresholds were measured to study the influence of masker and test signal duration on binaural unmasking for three different interaural phase relations (N0S0, N0S pi and N pi S0) and for test signal frequencies ranging from 200 to 800 Hz. Six observers participated in this study. An adaptive 3 Interval Forced Choice paradigm was employed. Reducing the signal duration from 250 to 20 ms results in an average binaural masking level difference (BMLD) increase of 2.5 dB for all frequencies and both dichotic conditions. Masker duration, however, has a more distinct influence on BMLD: a decrease from 500 to 25 ms reduces the BMLD in the N0S pi condition by 7 dB and in the N pi S0 condition up to 11 dB at low frequencies. These results reveal further evidence for different detection mechanisms in monaural and binaural masking experiments.

Adult

Phase effects in masking related to dispersion in the inner ear.

Phase effects in masking experiments using multitone maskers are usually associated with strong variations in the masker envelope. In this article, psychoacoustic experiments with such maskers that lead to phase-dependent threshold variations of up to 20 dB, although the phase transformation leaves the envelope unchanged, are described. However, after filtering the maskers with a realistic basilar membrane model, the envelopes are different owing to the models phase-dispersive properties. Comparison of model outputs with the experimental results reveals a strong correlation between the two for a wide range of parameters, provided one makes the additional assumption that the ear has a minimum integration time of a few milliseconds.

Auditory Threshold

[Normal values for the R peak amplitude in the abdominal fetal ECG at term and their significance for the detection of fetal postmaturity syndrome].

This is a retrospective study on 2 008 abdominal fetal ECGs of 1 005 patients. Standard values of R-peaks in the fetal ECG depending on the weeks of pregnancy are figured out. For the first time these standard values are shown on a percentile table and a percentile curve group. Depending on this standard values the frequency of fetal postmaturity is calculated. If the 90th percentile values for the R-peaks amplitude has been exceeded, then there is a 32% probability of severe fetal postmaturity in the pregnancy time of more than 290 days p.m., and a 20% probability if the pregnancy time is between 270-290 days p.m. Meconium has been observed in 44% of all cases, if pregnancy was prolonged more than 290 days p.m. and if in addition the R-amplitude was higher than the 90. percentile value. The abdominal fetal ECG therefore is a good additional method in cases of prolonged pregnancy to recognize fetal postmaturity.

Electrocardiography