Physiological control of a total artificial heart: conductance- and arterial pressure-based control.

To obtain a physiological response by a total artificial heart (TAH), while eliminating the hemodynamic abnormalities commonly observed with its use, we proposed the use of a conductance- and arterial pressure-based method (1/R control) to determine TAH cardiac output. In this study, we endeavored to make use of a variable more closely tied to central nervous system (CNS) efferents, systemic conductance, to provide the CNS with more direct control over the output of the TAH. The control equation that calculates the target cardiac output of the TAH was constructed on the basis of measurement of blood pressures and TAH flow. The 1/R control method was tested in TAH-recipient goats with an automatic method by using a microcomputer. In 1/R control animals, the typical TAH pathologies, such as mild arterial hypertension and substantial systemic venous hypertension, did not occur. Cardiac output varied according to daily activity level and exercise in a manner similar to that observed in natural heart goats. These results indicate that we have determined a control method for the TAH that avoids hemodynamic abnormalities exhibited by other TAH control systems and that exhibits physiological responses to exercise and daily activities under the conditions tested. The stability of the control and the complete lack of inappropriate excursions in cardiac output is suggestive of CNS involvement in stabilizing the system.

Animals

Development of the undulation pump total artificial heart.

The undulation pump is a small size continuous flow displacement type blood pump that has been developed for an artificial heart. Using undulation pumps, 2 types of implantable total artificial hearts (TAHs), the undulation pump TAH (UPTAH) type 1 (UPTAH 1) and UPTAH type 2 (UPTAH 2) were developed. Both UPTAHs were designed to be small enough to implant into the chest of a goat, the experimental animal. UPTAH 1 could be reduced in size to 75 mm in diameter and 78 mm in length. The weight was 520 g. UPTAH 2 could be reduced in size to 75 mm in diameter and 80 mm in length. The weight was 650 g. UPTAH 2 could be tested in an animal experiment using an adult female goat weighing 52.3 kg. The UPTAH 2 could be implanted successfully into the goat's chest with a good fit. The goat stood after the surgery and extubation and survived for 3 h and 40 min; thus, the potential of the UPTAH for a practical implantable TAH was demonstrated.

Animals

Use of a catecholamine sensor in the control of an artificial heart system.

An electrochemical sensor system to allow real-time measurement and feedback of catecholamine concentrations was developed for use in the control of artificial hearts. Electrochemical analyses were carried out using a carbon fiber working electrode, an Ag-AgCl reference electrode, and a potentiostat. The operating parameters of the pneumatically-driven artificial heart system were altered in accordance with the algorithm for changes in the catecholamine concentration. The minimum detectable concentrations of both adrenaline and noradrenaline in a mock circulatory system using a phosphate-buffered solution were approximately 1-2 ng/ml (10(-8) mol/L). An artificial heart control system utilizing this set-up performed satisfactorily without delay, although sensor sensitivity decreased when placed in goat plasma instead of a phosphate-buffered solution, due to the adsorption of various substances such as plasma proteins onto the electrodes. This study demonstrated the future feasibility of a feedback control system for artificial hearts using catecholamine concentrations.

Adsorption

Child abuse and neglect in Japan: coin-operated-locker babies.

The coin-operated-locker baby is a type of child abuse that may be unique to Japan. The term refers to newborns who are placed, while alive or dead, in coin-operated lockers. This practice has been decreased by specific measures. It is likely that social and economic variables in Japan account for differences in the frequency and types of child abuse cases when compared to American or European societies as social conditions in Japan change the reported incidence of child abuse may increase in the future. Recently, the government of Osaka organized a group specifically designed to deal with the detection and protection of abused and neglected children. In 1993, they published a manual on how to deal with child abuse, but the Japanese judicial administration still uses old laws for abuse cases. The development of new laws is occurring in parts of the country now. This paper introduces the present status of coping with child abuse and neglect in Japan.

Child

Basic study to develop the undulation pump for practical use: antithrombogenicity, hemolysis, and flow patterns inside the pump.

The undulation pump (formerly called the precessional displacement pump) is a continuous flow displacement-type blood pump that is being developed as an implantable total artificial heart. A new undulation pump was developed for chronic use and was examined with animal experiment and flow visualization studies. In the animal experiment using a left ventricular bypass in goats, severe hemolysis occurred. After driving for 12 h, thrombus formation inside the pump was found. In the flow visualization studies, the flow pattern showed that the flow inside the pump was a very complicated turbulent flow. Improvement of hemolysis and thrombus formation is important to realize implantable total artificial hearts using undulation pumps.

Animals

Development of a new apparatus to observe microcirculation chronically in continuous flow blood pump research.

To observe microcirculation chronically is an important key to the successful evaluation of the continuous flow blood pump. In this study, we succeeded in developing a new apparatus by which microcirculation could be observed chronically without a microscope in a conscious animal. The apparatus utilizes a charge coupled device (CCD). A thin living tissue, such as mesentery, is put directly on a highly integrated CCD and is lit up through the tissue with a light-emitting diode (LED). The vascular nets in the tissue are projected onto the CCD like a contact photograph, which is then sent to a television screen and which can be used to analyze their motion and function. A 0.5-inch CCD having 250,000 pixels was used in this study. The cover glass of the CCD was removed, and a fiber optic plate was fixed onto the surface of the CCD for the tissue to be able to contact with the apparatus surface without clearance. The CCD as well as the LED were molded with epoxy resin for electrical insulation. The apparatus was 35 mm wide and 12 mm high with a micro stand for an LED, which can be easily implanted into an animal. The apparatus was implanted into a rabbit for 12 h. The configuration of arterioles and venules, tens of micrometers in diameter, and their motions in subcutaneous tissue could be observed.

Animals

An epidemiologic and histopathological study of sudden cardiac death in Osaka Medical Examiner's Office.

From 1982 to 1986, 1230 sudden death cases were autopsied in Osaka Medical Examiner's Office. Among them, 810 cases were sudden cardiac deaths (SCD) including coronary heart disease (77%), cardiomyopathy (7%), valvular disease (3%). All SCD cases were dead within 24 hours of the appearance of the fatal symptoms, and most of them (72%) were considered instantaneous death. Many of the fatal symptoms began in bed (31%), at bath (17%), at toilet (8%), or at work (8%). Thirty-four percent of them were thought by themselves or by their families to be healthy before the death. Hypertension (38%), coronary heart disease (13%) and diabetes mellitus (11%) were the major past history recorded. Microscopic observation of the hearts of 200 cases autopsied in 1986 showed various cardiac lesions: hypertrophy, atrophy, degenerations of myocytes, cellular and fatty infiltrations of the interstitium. According to their cardiac lesions and degrees of severity of coronary sclerosis, patients who died suddenly were divided into 8 groups as follows: 1. myocardial infarction (41) 2. myocarditis (6) 3. hypertrophic cardiomyopathy (19) 4. chronic ischemia with severe coronary sclerosis (65) 5. chronic ischemia with moderate coronary sclerosis (27) 6. small vessel disease (18) 7. amyloidosis (1) 8. unknown (23). These results suggest that coronary heart disease and hypertension play an important role in SCD.

Adolescent

A statistical study of sudden cardiac death for past five years in Osaka medical, investigated at the Osaka Medical Examiner's Office.

From 1982 to 1986, there were 1230 sudden death cases autopsied in Osaka Medical Examiner's Office. Among them, 810 cases were classified cardiac deaths (SCDs) such as coronary heart disease (77%), cardiomyopathy (7%), valvular disease (3%). All SCD cases were dead within 24 hours after the appearance of the fatal symptoms, and most of them (72%) were supposed to be instantaneous death. Many of the fatal symptoms began in bed (31%), at bath (17%), at toilet (8%) or at work (8%). 34% of them were thought to be healthy by themselves or by their family members before their deaths. Hypertension (38%), coronary heart disease (13%) and diabetes mellitus (11%) were their major past histories recorded. Cardiac lesions such as myocardial hypertrophy, fibrosis and atherosclerosis of coronary artery were frequently admitted in SCD. SCD has been vigorously studied for a long time in various fields including legal medicine, and it has also attracted a great deal of public attention recently. To clarify the causes and the mechanisms of SCD, investigations of the actual situation of SCD cases is essential. Therefore, 1230 autopsy cases of SCD in Osaka Medical Examiner's Office for recent five years were statistically investigated.

Age Factors

Quantitative approach to determine the application time of the left ventricular assist device.

This study was designed to establish a method for determining the optimal time of the application of the left ventricular assist device from the viewpoint of the metabolism of the vital organs. Quantitative systemic low flow states were made utilizing goats with total artificial hearts. During these experiments, arterial lactate and pyruvate values were sequentially measured. The behavior of anaerobic metabolism during low cardiac output states and in the recovery process following normalization of the cardiac output was quantitatively described and evaluated. The experimental results are summarized as follows: If a time when the decay of arterial lactate ceases at a level above the normal level by greater than 30 mg/dl is observed despite the use of intraaortic balloon pumping, that time is the exact optimal time for application of the left ventricular assist device. There is a great possibility that circulatory failure will be irreversible if left ventricular assist pumping is not initiated before the arterial lactate value increases to greater than or equal to 140 mg/dl. The method of evaluating the alteration of anaerobic metabolism described in this study is useful for determining the application time of the left ventricular assist device.

Animals

In vitro and in vivo evaluation of a jellyfish valve for practical use.

A practical model (Model-1) of a jellyfish valve was developed, which was composed of a valve seat and a flexible membrane. The valve seat has 12 spokes to hold the membrane, and is made of solution-cast polyurethane coated with segmented polyurethane or Cardiothane. The flexible membrane is 200 microns thick, and made of segmented polyurethane or Cardiothane by a casting method. The valves were built into a sac type blood pump. In mock circulation tests, this jellyfish valve revealed performance superior to Bjork-Shiley (B-S) valves. No stagnation point was observed in the flow visualization study, and durability testing is ongoing beyond 7.5 months. The valves were used in animal artificial heart experiments for up to 112 days with good performance. No thrombi were formed on the valve membrane or around the spokes. Although a ring thrombus was observed behind the valve, it would be prevented by perfect adhesion of the valve seat to the blood pump. The plasma free hemoglobin level was less than 2 mg/dl during these experiments. These results suggest that a jellyfish valve (Model-1) is useful in ventricular assist devices, and in short-term bridge use of a total artificial heart.

Animals

Use of a total right heart bypass model for analyses of abnormal hemodynamics in total artificial heart animals, and the function and regulatory mechanisms of a natural heart.

By fixing the function of one ventricle, a total right heart bypass model can clarify the function and regulatory mechanism of the natural heart, and the etiology of abnormal hemodynamics in TAH animals such as increased CVP blood pressure and hepatic congestion. The pulmonary artery of a right heart bypass in a goat was clamped proximally; the pulmonary circulation was thus supplied entirely by the artificial heart and the systemic circulation by the natural heart. This model enabled studies of long-term effects of an artificial right heart on systemic circulation at a right heart output of 80-100 ml/kg/min; the response of the natural left heart to changes in output of the right heart; and the response of the natural left heart and artificial right heart to treadmill exercise. It was found that only slight increase in CVP or no increase in blood pressure was observed during the experiment (112 days); a rapid increase in output of the RAH resulted in an increase in left atrial pressure, stroke volume and output of the left ventricle, and a decrease in its heart rate at rest; and significant increase in both artificial right heart and natural left heart output and heart rates were observed during treadmill exercise, despite the marked decrease in left atrial pressure. The above results suggest that the increase in CVP and blood pressure in total artificial heart animals are not due to factors involving the artificial right heart, and that although left ventricular function acts in accordance with Starling's law at rest, this is no longer true during treadmill exercise.

Animals

Fabrication of a jellyfish valve for use in an artificial heart.

For a valve to be fabricated seamlessly into an artificial heart (AH) blood pump, a jellyfish valve has been developed, in which a thin membrane is fixed at the center of a valve seat having several spokes to protect against prolapse of the membrane. The valve is superior in performances to a Björk-Shiley valve, and reveals good blood compatibility. The valve would be very useful not only for AH animal study, but for future clinical use in infants to adults. Several institutions are already trying the valve. In this paper, the fabrication of the jellyfish valve is introduced, and in vitro and in vivo results summarized. A computer aided design (CAD) system was developed to cut a male wax mold of the valve seat. The input parameters to the CAD are diameter, height, thickness of rim, number of spokes, width and thickness of spokes, etc. Jellyfish valves with diameters of 4 to 27 mm have already been fabricated for many types of AHs and assist pumps.

Animals

The second and third model of the flow transformed pulsatile total artificial heart.

For the purpose of future total implantation, a new pulsatile total artificial heart, a flow transformed pulsatile total artificial heart (FTPTAH), in which the continuous flow from a single centrifugal pump (CFP) was converted to pulsatile flow by switching two three-way valves that could alternately perfuse the systemic and pulmonary circulation, was proposed, and the data from the prototype model were reported. As the next step, the second model, in which a CFP and a spool valve (SV) driven with a solenoid were fabricated in one piece, was made and tested in a mock circulatory system. The system could send 4.7 L/min of pulsatile output alternately to the pulmonary artery and aorta, with 30 and 100 mmHg afterload, respectively, at 3000 rpm CFP. However, three problems were encountered: the output was not enough, mixture or inversion of venous and arterial blood in the CFP would occur, and heat generation at the solenoid was very severe. To solve these problems, a third model was designed in the current study. To increase pump output, hydrodynamic analysis was performed. The SV was divided into inlet and outlet to control the blood mixture or inversion. To suppress heat generation, each SV was driven back and forth by two solenoids, one on each side of the SV. The model revealed satisfactory results in a mock circulatory system.

Biomedical Engineering

A new apparatus for chronic observation of the microcirculation in situ to evaluate artificial organ performance.

Chronic study of the peripheral circulation and metabolism is very important in evaluation of artificial organ performance. However, there has been no way to observe the microcirculation in situ, chronically and continuously, without restriction. In this study, the authors developed a new apparatus that could be implanted and connected to an artificial organ that would allow continuous observation of the microcirculation while the subject is awake. The apparatus uses a charge coupled device (CCD) under a new principle: thin living tissue, such as mesentery, is put directly on a highly integrated CCD and transilluminated with a light emitting diode (LED). The vascular nets in the tissue are projected onto the CCD like a contact photograph, which is sent to a television screen and can be analyzed for motion and function. A 0.5 inch CCD with 25K pixels was used in this study. The cover glass of the CCD was removed so the tissue would be able to directly contact the CCD surface. The CCD, as well as LED, were molded with hard polyurethane as electrical insulation. The apparatus is 35 mm in diameter and 10 mm high with a micro stand for lighting with the LED, which is easy to implant in a goat or calf. The resolution of this apparatus was tested by putting a micro scale on the CCD surface. Several tenths of micrometers could be seen. In an animal experiment with a rabbit, configurations of arterioles and venules and their motions could be observed continuously for a night until the electrical insulation was broken. This method might be a strong weapon in artificial organs research.

Animals

Blood compatibility of the jellyfish valve without anticoagulant.

The blood compatibility of the jellyfish valve was studied. Artificial heart (AH) blood pumps incorporating jellyfish valves were connected to 18 goats as total artificial hearts (TAHs) and pumped for 1 to 125 days without anticoagulant or antiplatelet drugs. No thrombus was formed on the valve membrane or around the valve seat. Scanning electron microscopy showed almost no platelet deposition or microfibrin clot formation on the valve membrane, including its central region; the spokes of the valve seat were also free from platelet and microfibrin clots. No calcification was observed during these tests, and plasma free hemoglobin was between 2 and 7 mg/dl. The jellyfish valve revealed good blood compatibility, even without anticoagulant use.

Animals