PubMed HealthSearch

Biomedical subjects

A Kreis

Publications and source records attributed to A Kreis.

13 recordsLinked to original sources

Asymptomatic left ventricular malposition of a transvenous pacemaker lead through a sinus venosus defect: follow-up over 17 years.

The case of a woman with an asymptomatic transvenous left ventricular endocardial pacemaker lead is presented. The chest X ray and the electrocardiogram suggested pacemaker catheter malposition. By two-dimensional echocardiography, the pacemaker lead was shown to cross from the left atrium through the mitral valve and implant in the left ventricular endocardium. The underlying sinus venosus defect and the passage of the electrode through this interatrial communication were directly visualized by transesophageal echocardiography. No thrombotic material attached to the lead was detected corresponding to the patient's uneventful course for surprisingly more than 17 years without evidence of past or present neurological deficiencies or of peripheral embolic phenomena. Thus, no operative correction was performed. Warfarin sodium therapy, however, was initiated.

Bundle-Branch Block

Real-time intravascular ultrasound imaging in humans.

The capability of obtaining cross-sectional, high resolution images of arteries with the use of ultrasound catheters has recently been demonstrated in animal studies. In this study the in vivo feasibility of intravascular ultrasound imaging in humans was evaluated. In 26 patients who had undergone diagnostic cardiac catheterization or iliofemoral arteriography, 1 of 3 different models of 20-MHz ultrasound catheters was advanced retrograde, into the iliac arteries and aorta or anterograde into the femoral arteries and real-time cross-sectional images of the arteries were obtained in all. In 10, the iliac arteries were normal and appeared circular and pulsatile with a 3-layered wall and crisply defined lumens. In 7 patients with nonobstructive plaques, the plaque was easily identified in the ultrasound image as a linear, bright, adynamic echo-dense structure. In 4 with obstructive disease in the iliac artery, the arterial lumen appeared irregular, bordered by a thickened, nonpulsatile wall. Variable grades of atheromatous abnormalities in the wall could be visualized. In all 5 patients with arteriographic evidence of obstructive disease of the femoral artery, intravascular ultrasound displayed reduced lumens and irregular borders with protruding high-intensity echoes in the wall. In all patients, the arterial lumen and the normal or abnormal wall were well visualized in the ultrasound images. There were no complications. This study thus demonstrates the feasibility of intravascular ultrasound imaging of arterial circulation in humans. With further improvements in catheter design and image quality, this imaging approach is likely to have a number of potential applications in the assessment of peripheral and coronary arterial diseases and in guiding interventional therapeutic procedures.

Aorta, Abdominal

The potential value of transoesophageal evaluation of individual pulmonary venous flow after an atrial baffle procedure.

Following a Mustard's procedure, transoesophageal echocardiography allowed the visualization of all 4 pulmonary veins in 7/12 patients (mean age 14.8 years) and of three veins in a further 2 patients. Both upper pulmonary veins could be visualized consistently. No patient had an isolated pulmonary venous stenosis. In 9 patients in sinus rhythm, computer analysis of Doppler tracings from the left upper pulmonary vein showed significantly lower systolic peak velocities (mean 0.39 +/- 0.10 m/s) and time velocity integrals (mean 6.9 +/- 1.66 cm) than in normal subjects (mean 0.6 +/- 0.09 m/s and 14.4 +/- 2.97 cm respectively; P less than 0.001). We postulate that this is due to compromised atrial relaxation and compliance. In contrast, patients in junctional rhythm (mean 10.7 vs. 7.7 cm in normal subjects). Flow reversal during early ventricular systole (due to tricuspid regurgitation or atrial contraction after retrograde conduction during junctional rhythm) was detected in 6/12 patients. These results confirm that the transoesophageal approach should allow the identification of isolated pulmonary venous obstruction after a Mustard procedure. In addition. detailed analysis of tracings of flow in the pulmonary veins can document the presence of compromised atrial relaxation and help to evaluate the severity of tricuspid regurgitation. It may provide a new index with which to assess impaired systemic ventricular function.

Adolescent

Simultaneous transesophageal atrial pacing and transesophageal two-dimensional echocardiography: a new method of stress echocardiography.

The diagnostic use of exercise echocardiography has been widely reported. However, transthoracic exercise echocardiography is inadequate in up to 20% of patients because of poor image quality related to exercise. In an attempt to overcome these limitations, a system was developed in which transesophageal echocardiography is combined with simultaneous transesophageal atrial pacing by means of the same probe. In a prospective study, transesophageal echocardiography was performed before, during and immediately after maximal atrial pacing in 50 patients with suspected coronary artery disease. Results of transesophageal stress echocardiography were considered abnormal when new pacing-induced regional wall motion abnormalities were observed. Correlative routine bicycle exercise testing was carried out in 44 patients. Cardiac catheterization was performed in all patients. The success rate in obtaining high quality diagnostic images was 100% by transesophageal echocardiography. All nine patients without angiographic evidence of coronary artery disease had a normal result on the transesophageal stress echocardiogram (100% specificity). Thirty-eight of 41 patients with coronary artery disease (defined as greater than or equal to 50% luminal diameter narrowing of at least one major vessel) had an abnormal result on the transesophageal stress echocardiogram (93% sensitivity). The sensitivity of the technique for one, two or three vessel disease was 85%, 100% and 100%, respectively, compared with 44%, 50% and 83%, respectively, for bicycle exercise testing; the 12 lead electrocardiogram (ECG) during rapid atrial pacing showed a sensitivity of 25%, 64% and 86%, respectively. Thus, rapid atrial pacing combined with simultaneous transesophageal echocardiography is a highly specific and sensitive technique for the detection of coronary artery disease. Ischemia-induced wall motion abnormalities were detected earlier than observed ECG changes. The technique appears to be particularly suited to patients who are unable to perform an active stress test or those with poor quality transthoracic echocardiograms.

Cardiac Catheterization

Intracardiac, intravascular, two-dimensional, high-frequency ultrasound imaging of pulmonary artery and its branches in humans and animals.

Intravascular ultrasound imaging is a promising new method for assessing vascular morphology. We evaluated the capability of intravascular ultrasound to quantify pulmonary artery (PA) morphology in vitro and explored the feasibility of in vivo PA imaging in animals and humans. In the in vitro study of 15 PA segments, we used a 20-MHz prototype ultrasound catheter. Intravascular ultrasound (y) provided crisp images of PA segments and demonstrated excellent correlations with anatomic measurements (x) in the estimation of luminal area (y = 0.89x + 2.95, r = 0.99, p less than 0.001), luminal diameter (n = 30, y = 0.79x + 0.96, r = 0.92, p less than 0.001), and vessel wall thickness (n = 60, y = 0.65x + 0.33, r = 0.85, p less than 0.001). We subsequently introduced the probe into the PA of 10 dogs and were able to obtain real-time, two-dimensional images of the main PA, its major branches, and farther smaller branches as far as the wedge level. To evaluate the in vivo feasibility of PA imaging in conscious humans, we used a commercially available, 20-MHz intravascular ultrasound (IVUS) catheter in 22 subjects through a femoral or jugular venous sheath at the end of standard diagnostic cardiac catheterization. In 20 subjects, we acquired dynamic, high-resolution, cross-sectional images of the proximal and distal PA. Changes in shape and decreasing luminal area could be clearly recognized as the IVUS catheter reached branching points and as it passed more distally. There were no complications.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals

Effects of atrial cardioplegia on the ischemic right ventricle after acute coronary artery occlusion and reperfusion.

Right atrial cardioplegia has been advocated as a simple method of delivering retrograde cardioplegia. Passive distention of the right heart inherent with right atrial cardioplegia has been shown to impair right ventricular function in a canine model of global ischemia. This study was designed to compare right ventricular performance after right atrial cardioplegia administered intermittently (n = 5) and continuously (n = 5) with coronary sinus retrograde cardioplegia (n = 5) and aortic root cardioplegia (n = 8) in a canine model of acute right ventricular ischemia and reperfusion. Right ventricular performance was assessed using the load-independent relationship of end-systolic pressure versus dimension (myocardial fiber length). Right ventricular performance was well preserved after reperfusion in those dogs protected with intermittent right atrial cardioplegia (95% of control). Results with continuous right atrial cardioplegia (66% of control) and coronary sinus retrograde cardioplegia (40% of control) demonstrated diminished postreperfusion right ventricular performance. Right ventricular performance in the group protected with aortic root cardioplegia was significantly impaired after reperfusion when compared with all retrograde groups (34% of control, p less than 0.05). In this model, postreperfusion right ventricular performance was preserved in the right atrial cardioplegia groups despite passive ventricular distention. All methods of retrograde cardioplegia resulted in superior preservation of right ventricular performance when compared with standard aortic root cardioplegia.

Animals

Intravascular ultrasound estimation of arterial stenosis.

The evaluation of the degree of reduction in the cross-sectional area of an artery has important pathophysiologic and therapeutic implications. Currently, no technique can easily provide this information. In this in vitro study we evaluated the potential of a new imaging technique, intravascular high frequency ultrasound angioscopy, in the estimation of percentage of cross-sectional area stenosis of an artery. To do this, we compared intravascular high frequency ultrasound to previously-validated external high frequency ultrasound and to anatomic estimation of arterial stenosis. Using a prototype intraluminal imaging catheter with a 20 MHz ultrasound transducer at its tip, we imaged 20 arterial segments of various size (15 to 90 mm2 lumen area by anatomy) in the control state and after experimental stenosis. These arterial segments were also imaged by external high frequency ultrasound. Lumen areas were measured from calibrated ultrasound images in the control state and after stenosis, and percentage of cross-sectional area stenosis was calculated. These data were compared to the percentage of area stenosis derived from calibrated anatomic photographs of the arteries taken in the control state and after stenosis. Both intravascular ultrasound angioscopy and external high frequency ultrasound yielded high-resolution, two-dimensional, circumferential images of the arteries. Alterations in vessel area and shape were apparent after creation of stenosis.(ABSTRACT TRUNCATED AT 250 WORDS)

Arteries