Photoexcitation of a volume plasmon in C60 ions.

Neutral C60 is well known to exhibit a giant resonance in its photon absorption spectrum near 20 eV. This is associated with a surface plasmon, where delocalized electrons oscillate as a whole relative to the ionic cage. Absolute photoionization cross-section measurements for C+60, C2+60, and C3+60 ions in the 17-75 eV energy range show an additional resonance near 40 eV. Time-dependent density functional calculations confirm the collective nature of this feature, which is characterized as a dipole-excited volume plasmon made possible by the special fullerene geometry.

Journal Article↗

Interferometer-controlled scanning transmission X-ray microscopes at the Advanced Light Source.

Two new soft X-ray scanning transmission microscopes located at the Advanced Light Source (ALS) have been designed, built and commissioned. Interferometer control implemented in both microscopes allows the precise measurement of the transverse position of the zone plate relative to the sample. Long-term positional stability and compensation for transverse displacement during translations of the zone plate have been achieved. The interferometer also provides low-distortion orthogonal x, y imaging. Two different control systems have been developed: a digital control system using standard VXI components at beamline 7.0, and a custom feedback system based on PC AT boards at beamline 5.3.2. Both microscopes are diffraction limited with the resolution set by the quality of the zone plates. Periodic features with 30 nm half period can be resolved with a zone plate that has a 40 nm outermost zone width. One microscope is operating at an undulator beamline (7.0), while the other is operating at a novel dedicated bending-magnet beamline (5.3.2), which is designed specifically to illuminate the microscope. The undulator beamline provides count rates of the order of tens of MHz at high-energy resolution with photon energies of up to about 1000 eV. Although the brightness of a bending-magnet source is about four orders of magnitude smaller than that of an undulator source, photon statistics limited operation with intensities in excess of 3 MHz has been achieved at high energy resolution and high spatial resolution. The design and performance of these microscopes are described.

Journal Article↗