PubMed Health⌕ Search

Biomedical subjects

A L Lewis

Publications and source records attributed to A L Lewis.

At least 19 recordsLinked to original sources

Synthesis of biocompatible poly[2-(methacryloyloxy)ethyl phosphorylcholine]-coated magnetite nanoparticles.

A well-defined, double-hydrophilic diblock copolymer comprising poly[2-(methacryloyloxy)ethyl phosphorylcholine]-block-(glycerol monomethacrylate) (PMPC30-PGMA30, where the numbers represent the average degrees of polymerization for each block) was evaluated for the synthesis of colloidally stable ultrafine magnetite sols. Sterically stabilized paramagnetic sols were prepared in aqueous solution by chemical coprecipitation of ferric and ferrous salts in the presence of this block copolymer. The PMPC30-PGMA30-stabilized magnetite sol had a mean transmission electron microscopy (TEM) diameter of 9.4 +/- 1.7 nm and a mean hydrodynamic diameter of 34 nm. This sol exhibited improved colloidal stability with respect to long-term storage and pH variation compared with magnetite sols prepared in the presence of alternative water-soluble homopolymers and diblock copolymers. Fourier transform infrared (FT-IR) spectroscopy, thermogravimetry, electron spectroscopy imaging (ESI), and zeta potential studies indicate that the PMPC30-PGMA30 diblock copolymer was adsorbed onto the surface of the sol via the PGMA30 block, with the PMPC30 chains acting as the stabilizing block. Such sterically stabilized sols are expected to be improved contrast agents for magnetic resonance imaging (MRI) applications.

Coated Materials, Biocompatible↗

Neutron reflection study of a water-soluble biocompatible diblock copolymer adsorbed at the air/water interface: the effects of pH and polymer concentration.

The effect of varying both the solution pH and copolymer concentration on the structure of layers of poly[2-(methacryloyloxy)ethyl phosphorylcholine-block-2-(dimethylamino)ethyl methacrylate] copolymer (denoted as MPC(30)-DMA(60), M(n) = 18,000) adsorbed at the air/water interface is studied using surface tension and specular neutron reflection. The surface structure of the adsorbed diblock copolymer is represented by a dense layer of 10-15 A on the air side, accompanied by a loose layer of 20-30 A extending into the aqueous phase. Although the uniform layer model generally provided a reasonable description of the adsorbed copolymer chains, some deviations were observed. A more detailed analysis showed that the distribution of the copolymer across the interface required a minimum of three layers to take into account the structural inhomogeneities. Refinement of the structural distributions involved the combined fitting of partially deuterated copolymer in null reflecting water and D(2)O and the fully hydrogenated copolymer in D(2)O, leading to a substantial improvement in the reliability of the structural profiles obtained. The data analysis showed an increase in surface excess at higher copolymer concentrations and at more alkaline pH. However, the copolymer layer was fully immersed in water under all conditions studied. Because the surface excess showed a steady increase across the cmc over the high pH range, we speculate that copolymer adsorption above the cmc involves the formation of surface micellar aggregates under these conditions.

Adsorption↗

Structural study of DNA condensation induced by novel phosphorylcholine-based copolymers for gene delivery and relevance to DNA protection.

Poly[2-(dimethylamino)ethyl methacrylate-b-2-methacryloyloxyethyl phosphorylcholine] (DMA-MPC) is currently under investigation as a new vector candidate for gene therapy. The DMA block has been previously demonstrated to condense DNA effectively. The MPC block contains a phosphorylcholine (PC) headgroup, which can be found naturally in the outside of the cell membrane. This PC-based polymer is extremely hydrophilic and acts as a biocompatible steric stabilizer. In this study, we assess in detail the morphologies of DNA complexes obtained using the diblock copolymer series DMA(x)MPC30 (where the mean degree of polymerization of the MPC block was fixed at 30 and the DMA block length was systematically varied) using transmission electron microscopy (TEM) and liquid atomic force microscopy (AFM). Both techniques indicate more compact complex morphologies (more efficient condensation) as the length of the cationic DMA block increases. However, the detailed morphologies of the DMA(x)MPC30-DNA complexes observed by TEM in vacuo and by AFM in aqueous medium are different. This phenomena is believed to be related to the highly hydrophilic nature of the MPC block. TEM studies revealed that the morphology of the complexes changes from loosely condensed structures to highly condensed rods, toroids, and oval-shaped particles as the DMA moiety increases. In contrast, morphological changes from plectonemic loops to flower-like and rectangular block-like structures, with an increase in highly condensed central regions, are observed by in situ AFM studies. The relative population of each structure is clearly dependent on the polymer molecular composition. Enzymatic degradation assays revealed that only the DMA homopolymer provided effective DNA protection against DNase I degradation, while other highly condensed copolymer complexes, as judged from TEM and gel electrophoresis, only partially protected the DNA. However, AFM images indicated that the same highly condensed complexes have less condensed regions, which we believe to be the initiation sites for enzymatic attack. This indicates that the open structures observed by AFM of the DNA complexation by the DMA(x)MPC30 copolymer series are closer to in vivo morphology when compared to TEM.

Biopolymers↗

Bacterial adhesion to phosphorylcholine-based polymers with varying cationic charge and the effect of heparin pre-adsorption.

The steady increase in the use of medical implants and the associated rise of medical device infections has fuelled the need for the production of biomaterials with improved biocompatibility. 2-(methacryloyloxyethyl phosphorylcholine) (MPC) based coatings have been used to improve the biocompatibility of a number of different medical devices. Recent studies have investigated the use of a phosphorylcholine modified with cationic charge to encourage specific bio-interaction. Until now the affect of cationic charge incorporation in MPC copolymers on bacterial adhesion has not been investigated. This study attempts to address this by investigating the affect of charge on four different strains of bacteria commonly associated with medical device infections. In addition, the affect of pre-incubating these MPC-copolymers in heparin is also evaluated as this has previously been shown to improve biocompatibility and reduce bacterial adhesion. Bacterial adhesion was assessed by ATP bioluminescence and Scanning Electron Microscopy (SEM). Results suggest that bacterial adhesion generally increased with increasing cationic charge. When samples were however, pre-incubated with heparin a significant reduction in bacterial adhesion to the MPC-based samples was observed. The heparin remained bound and effective at reducing bacterial adhesion to the cationic MPC-based samples even after three weeks incubation in PBS. To conclude, the MPC-based cationic polymer coatings complexed with heparin may provide a promising solution to reduce medical device related infections.

Absorption↗

The use of rhodamine 6G and fluorescence microscopy in the evaluation of phospholipid-based polymeric biomaterials.

A technique is described that allows the staining and subsequent visualization of polymers that contain the phosphorylcholine (PC) group. These materials are useful as bulk materials or coatings for the fabrication of medical devices. The staining method employs rhodamine 6G, which can be simply and rapidly applied to the polymer coating and imaged using fluorescence microscopy. The specificity of the staining for the PC polymers makes this technique suitable for the evaluation of a wide range of substrates and provides qualitative information on coating uniformity, coverage and morphology. It can be used to examine the durability of, and defects in, the coating. Statistical analysis of the fluorescent intensity by measuring the pixel value during imaging can allow for the method to be used as a quality control tool.

Biocompatible Materials↗

Phosphorylcholine-polycation diblock copolymers as synthetic vectors for gene delivery.

A novel 2-(dimethylamino)ethyl methacrylate-block-2-(methacryloyloxyethyl phosphorylcholine) (DMAEMA-MPC) diblock copolymer was synthesized and investigated as a new non-viral vector for gene delivery. The attractive perspective of this phosphorylcholine (PC)-based material is its propensity to condense DNA efficiently via the cationic DMAEMA block, as previously demonstrated for the respective homopolymer, with the MPC block acting as a biocompatible steric stabilizer. Two series of DMAEMA-MPC diblock copolymers were synthesized for evaluation, varying independently and systematically either MPC or DMAEMA block length. Markedly different DNA-copolymer complexes were observed depending on the copolymer molecular composition. Certain polymeric structures led to formation of highly condensed, sterically stabilized DNA complexes of 120-140 nm diameter, while some resulted in partly condensed DNA-polymer complexes with 'spaghetti' structures, indicating the importance of a copolymer composition to balance condensing and steric stabilization effect. A low level of non-specific cellular association of the complexes with optimized physicochemical properties was seen, indicating the role of MPC surface layer in the interactions with biological membranes and important property in preventing promiscuous interactions with tissues in the body and potentially allowing for cellular specific delivery of the condensates following the attachment of a targeting ligand.

Buffers↗

Controlled biological response on blends of a phosphorylcholine-based copolymer with poly(butyl methacrylate).

Phosphorylcholine (PC)-based polymers have been used in a variety of medical device applications to improve biocompatibility. Here, solutions containing poly(butyl methacrylate) (PBMA) and 2-methacryloyloxyethyl phosphorylcholine-co-lauryl methacrylate (MPC-co-LMA(2)) copolymer were spin-coated onto glass coverslips at various ratios ranging from 5:1 to 1:0 for each of the two components, respectively. The resulting blend coatings were shown to be phase-separated on the nanometre-scale by atomic force microscopy, the PC copolymer within the blend being preferentially expressed at the surface. The adsorption of two key blood proteins, fibrinogen and albumin were investigated using surface plasmon resonance as an indicator of biocompatibility. The adsorption of protein to a biomaterials' surface can then stimulate further biological responses. This study therefore, also investigates the materials ability to elicit an inflammatory response by studying the adhesion of human mononuclear cells to the material surface. The materials ability to support the adhesion and growth of other tissue cells was also evaluated, looking specifically at the adhesion and proliferation of rabbit corneal epithelial cells. Results suggest that the adsorption of proteins and the adhesion of both corneal epithelial cells and mononuclear cells are dependent on the composition of the PBMA:MPC-co-LMA(2) copolymer.

Adsorption↗

Wettable phosphorylcholine-containing polymers useful in blood filtration.

The use of phosphorylcholine (PC)-containing polymers has long been acknowledged as a method to improve the haemocompatibility of blood contacting devices. Such polymers were investigated for coating leukocyte filters, as a means of preserving precious platelet numbers and function. It was demonstrated that by use of such coated filters, the platelet recovery could be significantly increased by some 30%. This was however, balanced by a decrease in the leukocyte removal efficiency of the filter. More problematic however, was the poor critical wetting surface tension (CWST) of the filter (45 mNm(-1)). This was due to the surface expression of the hydrophobic groups of the polymer in air. In order to obtain a filter that could be immediately wetted by the blood and hence remove the need for any detrimental priming of the filter, the PC polymer was modified in order to reduce its hydrophobic content. A series of new cross-linkable polymers was developed that contained other hydrophilic monomers, yet could film-form to produce a coating stable to fluid contact. These materials demonstrated the required wetting characteristics (a CWST of >78 mNm(-1)), whilst retaining the excellent blood-contacting properties.

Journal Article↗

Long-term stability of a coronary stent coating post-implantation.

A coronary stent possessing a phosphorylcholine-based polymer coating was removed from a human patient 6 months after implantation and analyzed for the presence of the coating. An atomic force microscopy (AFM) technique has been employed to scrape away several 10- micro m(2) areas on the struts of the explanted stent. Scanning-electron microscopy (SEM) and tapping-mode AFM confirmed a surface coating had been removed in each case. Cross-sectional analysis and force-of-removal measurements showed that both coating depth and hardness were characteristic of that for the phosphorylcholine- (PC-) based coating prior to implantation. AFM amplitude-phase and distance curves from the explanted stent were comparable to those obtained when an unused stent was analyzed. Furthermore, laser ablation high-resolution inductively coupled-plasma mass spectometery (LA-HR-ICP-MS) was used to detect the low level of silicon present in the PC coating after explantation. The results from these techniques confirm that the stent coating is the original PC polymer and is not of biological origin, and support the long-term stability of the coating in vivo.

Aged↗

Analysis of a phosphorylcholine-based polymer coating on a coronary stent pre- and post-implantation.

There has been a move towards surface treatments for metallic coronary stents in an effort to improve their compatibility within the body and to provide a vehicle for the delivery of therapeutics. The Biodiv Ysio range of stents is characterised by a biocompatible coating comprised of a crosslinked phosphorylcholine (PC)-based polymer. In addition to a review of some of the data collected to support safety and efficacy of this device, this paper also describes a number of techniques that have been employed to both visualise and quantify the coating on the stent. Explantation of both coated and uncoated stents from porcine coronary arteries revealed that both coated and uncoated stents were >90% endothelialised after 5 days. Typical histological analysis of stented vessel sections after 4 and 12 weeks implantation showed the presence of cell types characteristic of the inflammatory response associated with the trauma caused by stent placement, with no evidence for any additional coating-related adverse inflammatory sequelae. Finally, it was demonstrated by AFM and SEM that both the thickness and force required to remove the coating were essentially unchanged after 6 months implantation. Thus, both the long-term stability and relative biological inertness of the coating has been confirmed in vivo, supporting its use as a vehicle for local drug delivery.

Animals↗

Crosslinkable coatings from phosphorylcholine-based polymers.

2-Methacryloyloxyethyl phosphorylcholine (MPC) was synthesised and then used in the preparation of crosslinked polymer membranes with lauryl methacrylate, hydroxypropyl methacrylate and trimethoxysilylpropyl methacrylate (crosslinker) comonomers. Some physical aspects of the membrane properties were evaluated in order to establish the basis for the synthesis of a series of post-crosslinkable polymers. These materials were made by copolymerisation of the constituent monomers via a free radical method, and characterised using NMR, FT-IR, viscometry and elemental analysis. The optimum crosslink density and conditions required for curing coatings of these polymers were investigated using atomic force microscopy (AFM) and showed the inclusion of 5 mol% silyl crosslinking agent to be ideal. A nanoindentation technique was employed to determine if the coating developed elasticity upon crosslinking. The biological properties of the coatings were evaluated using a variety of protein adsorption assays and blood contacting experiments, and an enzyme immunoassay was developed to detect E. coli in order to assess the level of bacterial adhesion to these biomaterials. Polymers of this type were shown to be very useful as coating materials for improving the biocompatibility of, or reducing the levels of adherent bacteria to medical devices.

Bacterial Adhesion↗

A novel phosphorylcholine-coated contact lens for extended wear use.

The preparation and characterisation of a new phosphorylcholine (PC)-coated silicone hydrogel contact lens for use in extended wear is described. The Michael-type addition of amines to acrylates forms the basis of the synthesis of a novel silicone-based macromer with hydrophilic functionality. It is demonstrated that this macromer can be combined with other silicone-based monomers, hydrophilic monomers and crosslinker to produce a contact lenses formulation. Examples of lenses with water contents of 33% and 46% are illustrated and their properties compared to other commercially available lenses. Materials with comparatively low modulus (<0.3 MPa) and adequate tear strength (>2-4MPa) with excellent elongation to break (>200%) can be obtained using this technology. In addition to the mechanical aspects. both the oxygen and solute permeabilities of the material can be controlled by the hydrophilic: hydrophobic monomer balance in the formulation. to obtain materials with attributes suitable for extended wear use. The PC coating is achieved by means of an in-mould coating (IMC) technique that produces a uniform and stable surface as determined by staining and XPS. The coating imparts both improved lens wettability (advancing contact angle of approximately 50 with virtually no hysteresis) and lower protein adsorption relative to the uncoated lens.

Adsorption↗

Liver tissue engineering: a role for co-culture systems in modifying hepatocyte function and viability.

A major limitation in the construction of a functional engineered liver is the short-term survival and rapid de-differentiation of hepatocytes in culture. Heterotypic cell-cell interactions may have a role to play in modulating long-term hepatocyte behavior in engineered tissues. We describe the potential of 3T3 fibroblast cells in a co-culture system to modulate function and viability of primary isolated rat hepatocytes. Over an 18-day period after isolation, hepatocytes in pure culture rapidly declined in viability, displayed sparse bile canaliculi, and lost two function markers, the secretion of albumin and ethoxyresorufin O-dealkylase (EROD) activity. In comparison, the hepatocytes within the co-cultures maintained viability, possessed well-formed canalicular systems, and displayed both functional markers. Fixed 3T3 cells or 3T3 cell conditioned medium did not substitute for the viable 3T3 cell co-culture system in preserving hepatocyte viability and functionality.

3T3 Cells↗

Synthesis and characterisation of phosphorylcholine-based polymers useful for coating blood filtration devices.

Copolymers of 2-methacryloyloxyethylphosphorylcholine (MPC) and lauryl methacrylate (LMA) of molar ratios MPC: LMAX where x = 1, 2 or 4, have been synthesised by two different free-radical polymerisation techniques. The solubility characteristics of the resulting materials were investigated in a variety of water: alcohol solvent mixtures and found to be influenced not only by the molar ratio of MPC: LMA, but also the method of synthesis. A window of solubility was observed for certain copolymers and the alcohol used in the solvent mixture was also found to have a profound influence on the solubility profile of the polymers. These materials were soluble in a wider range of aqueous methanol mixtures compared to aqueous mixtures of higher aliphatic alcohols, such as ethanol or isopropyl alcohol, which was rationalised in terms of the affinity of the phosphorylcholine headgroup for the various alcohols relative to water. 1H nuclear magnetic resonance spectroscopy was used to further examine the solution properties of the copolymers in various solvents. The copolymer MPC: LMA2 was coated onto a variety of substrates from both alcohol-only and water: alcohol solvent systems and the surface properties of the films compared by static and dynamic contact angle, atomic force microscopy (AFM) and attenuated internal reflectance Fourier transform infrared spectroscopy (ATR-IR). The coating formed from the water: alcohol solvent was found to be hydrophilic in nature, possessing spontaneous wettability, whereas films formed from alcohol-only solvents were hydrophobic, and only on conditioning with water were more wettable surfaces attained. This phenomenon was applied in the coating of leukocyte filtration material, where the aqueous-based systems demonstrated lower critical wetting surface tension (CWST) and shorter wetting times relative to both uncoated filters and those coated from alcohol-only systems. The haemocompatibility of the coated filters was equivalent for both coating solvent systems. employed, and far superior when compared to the uncoated control.

Alcohols↗

Combinatorial interactions regulate cardiac expression of the murine adenylosuccinate synthetase 1 gene.

The mammalian heart begins contracting at the linear tube stage during embryogenesis and continuously pumps, nonstop, throughout the entire lifetime of the animal. Therefore, the cardiac energy metabolizing pathways must be properly established and efficiently functioning. While the biochemistry of these pathways is well defined, limited information regarding the regulation of cardiac metabolic genes is available. Previously, we reported that 1.9 kilobase pairs of murine adenylosuccinate synthetase 1 gene (Adss1) 5'-flanking DNA directs high levels of reporter expression to the adult transgenic heart. In this report, we define the 1.9-kilobase pair fragment as a cardiac-specific enhancer that controls correct spatiotemporal expression of a reporter similar to the endogenous Adss1 gene. A 700-base pair fragment within this region activates a heterologous promoter specifically in adult transgenic hearts. Proteins present in a cardiac nuclear extract interact with potential transcription factor binding sites of this region and these cis-acting sites play important regulatory roles in the cardiac expression of this reporter. Finally, we report that several different cardiac transcription factors trans-activate the 1.9HSCAT construct through these sites and that combinations result in enhanced reporter expression. Adss1 appears to be one of the first target genes identified for the bHLH factors Hand1 and Hand2.

Adenylosuccinate Synthase↗

Structure and expression of the murine muscle adenylosuccinate synthetase gene.

A muscle-specific isoform of adenylosuccinate synthetase (AdSS1, EC) is one of three enzymes that constitute the purine nucleotide cycle, a muscle-specific metabolic cycle. Previously, we showed that the muscle Adss1 gene was highly expressed in both skeletal muscle and heart of the adult mouse. Here we have shown that the Adss1 gene is initially activated early in embryonic development in skeletal muscle and heart precursors and is subsequently up-regulated perinatally. The earliest detectable gene expression corresponds with the establishment of the first myogenic and cardiac lineages. To allow identification of the genetic signals controlling this developmental pattern of expression, the Adss1 gene was cloned and its structure determined. Transgenic analysis has shown that 1.9 kilobase pairs of 5' flank can activate expression in skeletal muscle progenitors and direct enhanced expression to adult cardiac muscle. Sequence analysis of the promoter and 5' flanking region revealed the presence of numerous potential muscle-specific cis-regulatory elements.

Adenine Nucleotides↗