Image mottle in abdominal CT.

RATIONALE AND OBJECTIVES: To investigate image mottle in conventional CT images of the abdomen as a function of radiographic technique factors and patient size. METHODS: Water-filled phantoms simulating the abdomens of adult (32 cm in diameter) and pediatric (16 cm in diameter) patients were used to investigate image mottle in CT as a function of x-ray tube potential and mAs. CT images from 39 consecutive patients with noncontrast liver scans and 49 patients with iodine contrast scans were analyzed retrospectively. Measurements were made of the mean liver parenchyma Hounsfield unit value and the corresponding image mottle. RESULTS: For a given water phantom and x-ray tube potential, image mottle was proportional to the mAs-0.5. Increasing the phantom diameter from 16 cm (pediatric) to 32 cm increased the mottle by a factor of 2.4, and increasing the x-ray tube potential from 80 kVp to 140 kVp reduced the mottle by a factor of 2.5. All patients were scanned at 120 kVp, with no correlation between patient size and the x-ray tube mAs. The mean mottle level was 7.8 +/- 2.2 and 10.0 +/- 2.5 for the noncontrast and contrast studies, respectively. An increase in patient diameter of 3 cm would require approximately 65% more mAs to maintain the same level of image mottle. CONCLUSIONS: The mottle in abdominal CT images may be controlled by adjusting radiographic technique factors, which should be adjusted to take into account the size of the patient undergoing the examination.

Adult↗

Radiation effective doses to patients undergoing abdominal CT examinations.

PURPOSE: To determine the radiation effective dose to adult and pediatric patients undergoing abdominal computed tomographic (CT) examinations. MATERIALS AND METHODS: Technique factors were obtained for three groups of randomly selected patients undergoing abdominal CT examinations: 31 children aged 10 years or younger; 32 young adults aged 11-18 years; and 36 adults older than 18 years. The radiographic techniques, together with the measured cross sections of patients, were used to estimate the total energy imparted to each patient. Each value of energy imparted was subsequently converted into the corresponding effective dose to the patient, taking into account the mass of the patient. RESULTS: All abdominal CT examinations were performed at 120 kVp with a section thickness of approximately 7 mm for all sizes of patients. The mean number of CT sections increased from 22.0 for children to 31.5 for adults, and the mean quantity of x radiation in milliampere-seconds increased from 220 mAs for children to 290 mAs for adults. The mean values (+/- SD) of energy imparted were 72.1 mJ +/- 24.4 for children, 183.5 mJ +/- 44.8 for young adults, and 234.7 mJ +/- 89.4 for adults. The corresponding mean values of patient effective dose were 6.1 mSv +/- 1.4 for children, 4.4 mSv +/- 1.0 for young adults, and 3.9 mSv +/- 1.1 for adults. CONCLUSION: Values of energy imparted to patients undergoing abdominal CT examinations were a factor of three higher in adults than in children, but the corresponding patient effective doses were 50% higher in children than in adults.

Abdomen↗