PubMed Health⌕ Search

Biomedical subjects

A L Muzikant

Publications and source records attributed to A L Muzikant.

5 recordsLinked to original sources

Validation of three-dimensional conduction models using experimental mapping: are we getting closer?

The anisotropic material properties, irregular geometry, and specialized conduction system of the heart all affect the three-dimensional (3D) spread of electrical activation. A limited number of research groups have tried accounting for these features in 3D conduction models to investigate more thoroughly their observations of cardiac electrical activity in 3D experimental preparations. The full potential of these large scale conduction models, however, has not been realized because of a lack of quantitative validation with experiment. Such validation is critical in order to use the models to predict the electrical response of the myocardium to drugs or electrical stimulation. In this paper, a quantitative, experimental validation of paced activation in a 3D conduction model of a 3 cm x 3 cm x 1 cm section of the ventricular wall is presented. Epicardial and intramural pacing stimuli were applied in the center of a 528 channel electrode plaque sutured to the left ventricle in dogs. Unipolar electrograms were recorded at 2 kHz during and after pacing. Fiber directions within the tissue below the electrodes were estimated histologically and from pace-mapping. Simulated epicardial electrograms were computed for surface paced beats using our 3D bidomain model of the mapped tissue volume incorporating the measured fiber directions. Extracellular potentials and isochronal maps resulting from paced activations in both model and experiment were directly compared. Preliminary results demonstrate that our 3D model reproduces qualitatively such key features of the experimental data as electrogram morphologies and epicardial conduction velocities. Though quantitative agreement between model and experiment was only moderate, the validation approach described herein is an essential first step in assessing the predictive capability of present day conduction models.

Animals↗

Bipolar stimulation of a three-dimensional bidomain incorporating rotational anisotropy.

A bidomain model of cardiac tissue was used to examine the effect of transmural fiber rotation during bipolar stimulation in three-dimensional (3-D) myocardium. A 3-D tissue block with unequal anisotropy and two types of fiber rotation (none and moderate) was stimulated along and across fibers via bipolar electrodes on the epicardial surface, and the resulting steady-state interstitial (phi e) and transmembrane (Vm) potentials were computed. Results demonstrate that the presence of rotated fibers does not change the amount of tissue polarized by the point surface stimuli, but does cause changes in the orientation of phi e and Vm in the depth of the tissue, away from the epicardium. Further analysis revealed a relationship between the Laplacian of phi e, regions of virtual electrodes, and fiber orientation that was dependent upon adequacy of spatial sampling and the interstitial anisotropy. These findings help to understand the role of fiber architecture during extracellular stimulation of cardiac muscle.

Anisotropy↗

Magnetic resonance myocardial fiber-orientation mapping with direct histological correlation.

Functional properties of the myocardium are mediated by the tissue structure. Consequently, proper physiological studies and modeling necessitate a precise knowledge of the fiber orientation. Magnetic resonance (MR) diffusion tensor imaging techniques have been used as a nondestructive means to characterize tissue fiber structure; however, the descriptions so far have been mostly qualitative. This study presents a direct, quantitative comparison of high-resolution MR fiber mapping and histology measurements in a block of excised canine myocardium. Results show an excellent correspondence of the measured fiber angles not only on a point-by-point basis (average difference of -2.30 +/- 0.98 degrees, n = 239) but also in the transmural rotation of the helix angles (average correlation coefficient of 0.942 +/- 0.008 with average false-positive probability of 0.004 +/- 0.001, n = 24). These data strongly support the hypothesis that the eigenvector of the largest MR diffusion tensor eigenvalue coincides with the orientation of the local myocardial fibers and underscore the potential of MR imaging as a noninvasive, three-dimensional modality to characterize tissue fiber architecture.

Animals↗

Paced activation mapping reveals organization of myocardial fibers: a simulation study.

INTRODUCTION: A three-dimensional bidomain model of a block section of both the right and left ventricular walls that included rotational anisotropy and fiber curvature was used to investigate potential distributions generated during paced activation mapping. Unlike previous large-scale tissue models, the extracellular stimulus was included. METHODS AND RESULTS: The model was used to test the hypothesis that information about the underlying tissue structure (surface fiber angle gradients, amount of fiber rotation per unit depth, and anisotropy) can be extracted from surface potential distributions during stimulation. Results from distributions during stimulation were compared to those obtained using the distributions during activation. To better correlate results to possible experimental measurements, the analysis was performed using a 21 X 21 grid of "electrode" sites, each separated by 1 mm. Fiber orientation was estimated from the surface data by: (1) curve-fitting the elliptical shape of the epicardial potential distribution during stimulation; (2) identifying the location of the potential maxima leading the wavefront during early activation; and (3) for epicardial stimuli, curve-fitting the elliptical shape of the activation isochrones. Results show that surface potential distributions from the stimulus can be used to estimate fiber orientation; however, the accuracy of the reconstruction is highly dependent on the amount of fiber rotation per unit depth. CONCLUSIONS: Extracellular potential data during and after stimulation is shown to reflect the organization of myocardial fibers and, as such, could be used to characterize the three-dimensional anisotropic electrical properties in situ.

Electric Stimulation↗

Anisotropy, fiber curvature, and bath loading effects on activation in thin and thick cardiac tissue preparations: simulations in a three-dimensional bidomain model.

INTRODUCTION: A modeling study is presented to explore the effects of tissue conductivity, fiber orientation, and presence of an adjoining extracellular volume conductor on electrical conduction in cardiac muscle. Simulated results are compared with those of classical in vitro experiments on superfused thin layer preparations and on whole hearts. METHODS AND RESULTS: The tissue is modeled as a three-dimensional bidomain block adjoining an isotropic bath. In the thin layer model, the fibers are assumed parallel. In the thick block model, fiber rotation, curvature, and tipping are incorporated. Results from the thin layer model explain experimental observations that the rate of rise of the entire action potential upstroke is faster and the magnitude of the extracellular potential is smaller across fibers than along fibers in a uniformly propagating front. The simulation identified that this behavior only arises in tissue with unequal anisotropy in the two spaces and adjoining an extracellular bath. Simulated conduction and potential distributions in the thick block model are shown to well approximate experimental maps. The potentials are sensitive to changes in the fiber orientations. A slight 5 degrees tipping of intramural fibers out of the planes parallel to the epicardium and endocardium will lead to an asymmetry of the magnitudes of the positive regions. In addition, the introduction of fiber curvature leads to more realistic isochrone and extracellular potential distributions. The orientation of the central negative region of the extracellular potential is shown to be determined by the average of the fiber direction at the plane of pacing and the plane of recording. CONCLUSIONS: The simulations demonstrate the sensitivity of spread of activation and potential time courses and distributions to the underlying electrical properties in both thick and thin slabs. The bidomain model is shown to be a useful representation of cardiac tissue for interpreting experimental data of activation.

Action Potentials↗