PubMed Health⌕ Search

Biomedical subjects

A Lewenstam

Publications and source records attributed to A Lewenstam.

9 recordsLinked to original sources

Modeling of divalent/monovalent ion selectivity of ion-exchanger-based solvent polymeric membranes doped with coexchanger

It is shown that the addition of a coexchanger does not always improve the selectivity of an ion-selective electrode. As a model case, the selectivity toward divalent primary ions I2+ in the presence of monovalent interference J+ is numerically simulated for membranes based on ion-exchanger R- and doped with a coexchanger (ionic additive) S+. It is, for the first time, demonstrated that the addition of a coexchanger, together with a high mobility of ion-exchanger sites, may be either beneficial or harmful to selectivity. Accordingly, two distinctive representatives of systems, i.e., membrane/solution are discussed. The theory is illustrated with experimental data obtained from PVC membranes based on calcium bis(2ethylhexyl)-phosphate plasticized with tris(2ethylhexyl)phosphate and doped with tetradecylammonium. Electrodes with these membranes exhibit both types of selectivity behavior. Interference from lithium with a calcium response may be sufficiently decreased by the addition of tetradecylammonium, while the interference from potassium and cesium was increased in the doped membranes.

Journal Article↗

Magnesium. An update on physiological, clinical and analytical aspects.

There is an increased interest in the role of magnesium ions in clinical medicine, nutrition and physiology. The characteristics of the binding of magnesium and calcium ions to various components, macromolecules and biological membranes are described. Magnesium affects many cellular functions, including transport of potassium and calcium ions, and modulates signal transduction, energy metabolism and cell proliferation. The mechanism of cellular uptake and efflux of magnesium, its intracellular transport, intestinal absorption, renal excretion and the effect of hormones on these are reviewed. Magnesium deficiency is not uncommon among the general population: its intake has decreased over the years especially in the western world. The magnesium supplementation or intravenous infusion may be beneficial in various diseased states. Of special interest is the magnesium status in alcoholism, eclampsia, hypertension, atherosclerosis, cardiac diseases, diabetes, and asthma. The development of instrumentation for the assay of ionized magnesium is reviewed, as are the analytical procedures for total magnesium in blood and free magnesium in the cytosol. The improved procedures for the assay of different magnesium states are useful in understanding the role of magnesium in health and disease.

Calcium↗

Use of ion-selective electrodes for blood-electrolyte analysis. Recommendations for nomenclature, definitions and conventions. International Federation of Clinical Chemistry and Laboratory Medicine (IFCC). Scientific Division Working Group on Selective Electrodes.

This paper will familiarize the reader with the terms used to describe the behavior of ion-selective electrodes, particularly in relation to their use in clinical chemistry for determination of blood electrolyte cations. It serves as an introduction to a series of papers dealing with important cations in blood, namely calcium, sodium, and potassium. The detailed relationships between the ion activity determined by means of ion-selective electrode potentiometry in undiluted specimens, and the total substance concentration measured by flame atomic-emission spectrometry are described by flow chart and equations. Adoption of a convention for reporting results is recommended. The Working Group on Selective Electrodes has taken into account recent revisions of IUPAC recommendations on nomenclature and selectivity coefficient determinations for ion-selective electrodes, and benefited from the experience of a member of the WG, who was also involved in the IUPAC discussions. Nomenclature for determined quantities follows previous IUPAC/IFCC joint recommendations.

Electrodes↗

Recommendations for measurement of and conventions for reporting sodium and potassium by ion-selective electrodes in undiluted serum, plasma or whole blood. International Federation of Clinical Chemistry and Laboratory Medicine (IFCC). IFCC Scientific Division Working Group on Selective Electrodes.

Ion-selective electrodes (ISEs) respond to ion-activity and therefore do not sense substance concentration directly. However, it is recognized that sodium and potassium in plasma will continue to be expressed for clinical purposes in terms of substance concentration (mmol/l). A convention is proposed whereby for routine clinical purposes results of ISE measurements of sodium and potassium in undiluted plasma should be reported in terms of substance concentration (mmol/l). In specimens with normal concentrations of plasma water, total CO2, lipids, protein and pH, the values will concur with the total substance concentration as determined for example by flame atomic emission spectrometry (FAES) or ISE measurements on diluted samples. In specimens with abnormal concentrations of plasma water, the results will differ. However, under these circumstances, measurements of sodium and potassium by ISE in the undiluted sample will more appropriately reflect the activity of sodium and potassium and are therefore clinically more relevant than the determination in diluted samples. Detailed recommendations are made about practical procedures to achieve this. The recommended name for this quantity is the substance concentration of ionized sodium or ionized potassium in plasma, as opposed to total sodium or total potassium determined by, e.g. FAES, or ISE measurements on diluted samples.

Calibration↗

IFCC recommended reference method for the determination of the substance concentration of ionized calcium in undiluted serum, plasma or whole blood.

A reference method is described for the determination of the substance concentration of ionized calcium in plasma by which ionized calcium (free or unbound) may be reliably determined on the basis of calibration with aqueous solutions with known concentration of ionized calcium. The composition of the calibration solutions is chosen such that the activity coefficient of the calcium ion is assumed to be identical both in the calibration solutions and in "normal" plasma, i.e. by convention, the ionic strength (Im) is 0.160 mol/kg. The convention is adopted of reporting ionized calcium measurements as concentration expressed as mmol/l. The proposed reference method for ionized calcium measurement in plasma is based on the use of a cell consisting of an external reference electrode with a saturated potassium chloride liquid/liquid junction in combination with a calcium ion-selective membrane electrode of defined construction and performance. Procedures for using the reference cell and a protocol for sample measurement are described. The preparation of the calibration solutions to be used are described in detail in Appendix A, secondary calibration solutions and check standards in Appendix B, and reference cell vessel design in Appendix C.

Blood↗

Design and pitfalls of ion selective electrodes.

Design of ion-selective electrodes (ISEs) currently used in clinical analysis is presented. The theory of these sensors is outlined. Problems specific for the application of ISEs in clinical analysis are discussed.

Chemistry, Clinical↗

Characterization, standardization and experiences with KONE ISE for Mg2+.

The principles of a fully automated potentiometric determination of ionized magnesium in human blood serum are presented. By incorporating a magnesium selective electrode, into a commercially available six channel electrolyte analyzer (Microlyte 6, KONE Instruments, Finland), determination of the biologically-active, ionized fraction of magnesium has been made possible. In this paper, the analytical performance of the measurement system is presented and determination of ionized magnesium in real patient samples is discussed with special attention to the significance of this new parameter.

Autoanalysis↗