Publications and source records attributed to A Lomax.

12 recordsLinked to original sources

Initial experience of using an active beam delivery technique at PSI.

At PSI a new proton therapy facility has been assembled and commissioned. The major features of the facility are the spot scanning technique and the very compact gantry. The operation of the facility was started in 1997 and the feasibility of the spot scanning technique has been demonstrated in practice with patient treatments. In this report we discuss the usual initial difficulties encountered in the commissioning of a new technology, the very positive preliminary experience with the system and the optimistic expectations for the future. The long range goal of this project is to parallel the recent developments regarding inverse planning for photons with a similar advanced technology optimized for a proton beam.

Humans

Dose calculation models for proton treatment planning using a dynamic beam delivery system: an attempt to include density heterogeneity effects in the analytical dose calculation.

The gantry for proton radiotherapy at the Paul Scherrer Institute (PSI) is designed specifically for the spot-scanning technique. Use of this technique to its full potential requires dose calculation algorithms which are capable of precisely simulating each scanned beam individually. Different specialized analytical dose calculations have been developed, which attempt to model the effects of density heterogeneities in the patient's body on the dose. Their accuracy has been evaluated by a comparison with Monte Carlo calculated dose distributions in the case of a simple geometrical density interface parallel to the beam and typical anatomical situations. A specialized ray casting model which takes range dilution effects (broadening of the spectrum of proton ranges) into account has been found to produce results of good accuracy. This algorithm can easily be implemented in the iterative optimization procedure used for the calculation of the optimal contribution of each individual scanned pencil beam. In most cases an elemental pencil beam dose calculation has been found to be most accurate. Due to the long computing time, this model is currently used only after the optimization procedure as an alternative method of calculating the dose.

Algorithms

Intensity modulation methods for proton radiotherapy.

The characteristic Bragg peak of protons or heavy ions provides a good localization of dose in three dimensions. Through their ability to deliver laterally and distally shaped homogenous fields, protons have been shown to be a precise and practical method for delivering highly conformal radiotherapy. However, in an analogous manner to intensity modulation for photons, protons can be used to construct dose distributions through the application of many individually inhomogeneous fields, but with the localization of dose in the Bragg peak providing the possibility of modulating intensity within each field in two or three dimensions. We describe four different methods of intensity modulation for protons and describe how these have been implemented in an existing proton planning system. As a preliminary evaluation of the efficacy of these methods, each has been applied to an example case using a variety of field combinations. Dose-volume histogram analysis of the resulting dose distributions shows that when large numbers of fields are used, all techniques exhibit both good target homogeneity and sparing of neighbouring critical structures, with little difference between the four techniques being discerned. As the number of fields is decreased, however, only a full 3D modulation of individual Bragg peaks can preserve both target coverage and sparing of normal tissues. We conclude that the 3D method provides the greatest flexibility for constructing conformal doses in challenging situations, but that when large numbers of beam ports are available, little advantage may be gained from the additional modulation of intensity in depth.

Computing Methodologies

Potential role of proton therapy in the treatment of pediatric medulloblastoma/primitive neuro-ectodermal tumors: spinal theca irradiation.

PURPOSE: Conventional postoperative photon-beam radiotherapy to the spine in children with medulloblastoma/PNET is associated with severe late effects. This morbidity (growth and developmental) is related to the exit dose of the beams and is particularly severe in young children. With the purpose of reducing this toxicity, a dosimetric study was undertaken in which proton therapy was compared to standard megavoltage photon treatment. METHODS AND MATERIALS: The results of a comparative dosimetric study are presented in such a way that the dose distribution achievable with a posterior modulated 100 MeV proton beam (spot scanning method) is compared with that of a standard set of posterior 6 MV x-ray fields. The potential improvements with protons are evaluated, using dose-volume histograms to examine the coverage of the target as well as the dose to the vertebral bodies (growth plates), lungs, heart, and liver. RESULTS: The target (i.e., the spinal dural sac) received the full prescribed dose in both treatment plans. However, the proportions of the vertebral body volume receiving > or = 50% of the prescribed dose were 100 and 20% for 6 MV x-rays and protons, respectively. For 6 MV x-rays > 60% of the dose prescribed to the target was delivered to 44% of the heart volume, while the proton beam was able to completely avoid the heart, the liver, and in all likelihood the thyroid and gonads as well. CONCLUSION: The present study demonstrates a potential role of proton therapy in decreasing the dose (and toxicity) to the critical structures in the irradiation of the spinal neuraxis in medulloblastoma/PNET. The potential bone marrow and growth arrest sparing effects make this approach specially attractive for intensive chemotherapy protocols and for very young children. Sparing the thyroid gland, the posterior heart wall, and the gonads may be additional advantages in assuring a long-term posttreatment morbidity-free survival.

Brain Neoplasms

Potential role of proton therapy in the treatment of pediatric medulloblastoma/primitive neuroectodermal tumors: reduction of the supratentorial target volume.

PURPOSE: One of the components of radiotherapy (RT) in medulloblastoma/primitive neuroectodermal tumors is the prophylactic irradiation of the whole brain (WBI). With the aim of reducing late neuropsychologic morbidity a CT-scan-based dosimetric study was undertaken in which treatment was confined mainly or exclusively to supratentorial sites considered at high risk for disease recurrence. METHODS AND MATERIALS: A comparative dosimetric study is presented in which a three field (two laterals and one posterior) proton plan (spot scanning method) is compared with a two-field conventional WBI 6 MV x-ray plan, to a 6-field "hand-made" 6 MV x-ray plan, and to a computer-optimized 9-field "inverse" 15 MV x-ray plan. For favorable patients, 30 Gy were delivered to the ventricles and main cisterns, the subfrontal and subtemporal regions, and the posterior fossa. For the unfavorable patients, 10 Gy WBI preceeded a boost to 30 Gy to the same treatment volume chosen for favorable patients. The dose distribution was evaluated with dose-volume histograms to examine the coverage of the targets as well as the dose to the nontarget brain and optical structures. In addition, the risks of radiation-related late neuropsychologic effects after WBI were collected from the literature and used to predict normal tissue complication probabilities (NTCPs) for an intelligence quotient deficit after treatment with photon or proton beams. RESULTS: Proton beams succeeded better in reducing the dose to the brain hemispheres and eye than any of the photon plans. A 25.1% risk of an IQ score <90 was predicted after 30 Gy WBI. Almost a 10% drop in the predicted risk was observed when using proton beams in both favorable and unfavorable patients. However, predicted NTCPs for both optimized photon plans ("hand made" and "inverse") were only slightly higher (0.3-2.5%) than those of proton beams. An age-modifying factor was introduced in the predictive NTCP model to assess for IQ differences in relation with age at irradiation. Children with ages between age 4 to 8 benefitted most from the dose reduction in this exercise (similar NTCP predictions for both proton and "inverse" plans). CONCLUSION: Modulated proton beams may help to significantly reduce the irradiation of normal brain while optimally treating the supratentorial subsites at higher risk for relapse. A decrease in morbidity can be expected from protons and both optimized proton plans compared to WBI.

Brain Neoplasms

Proton dosimetry intercomparison.

BACKGROUND AND PURPOSE: Methods for determining absorbed dose in clinical proton beams are based on dosimetry protocols provided by the AAPM and the ECHED. Both groups recommend the use of air-filled ionization chambers calibrated in terms of exposure or air kerma in a 60Co beam when a calorimeter or Faraday cup dosimeter is not available. The set of input data used in the AAPM and the ECHED protocols, especially proton stopping powers and w-value is different. In order to verify inter-institutional uniformity of proton beam calibration, the AAPM and the ECHED recommend periodic dosimetry intercomparisons. In this paper we report the results of an international proton dosimetry intercomparison which was held at Loma Linda University Medical Center. The goal of the intercomparison was two-fold: first, to estimate the consistency of absorbed dose delivered to patients among the participating facilities, and second, to evaluate the differences in absorbed dose determination due to differences in 60Co-based ionization chamber calibration protocols. MATERIALS AND METHODS: Thirteen institutions participated in an international proton dosimetry intercomparison. The measurements were performed in a 15-cm square field at a depth of 10 cm in both an unmodulated beam (nominal accelerator energy of 250 MeV) and a 6-cm modulated beam (nominal accelerator energy of 155 MeV), and also in a circular field of diameter 2.6 cm at a depth of 1.14 cm in a beam with 2.4 cm modulation (nominal accelerator energy of 100 MeV). RESULTS: The results of the intercomparison have shown that using ionization chambers with 60Co calibration factors traceable to standard laboratories, and institution-specific conversion factors and dose protocols, the absorbed dose specified to the patient would fall within 3% of the mean value. A single measurement using an ionization chamber with a proton chamber factor determined with a Faraday cup calibration differed from the mean by 8%. CONCLUSION: The adoption of a single ionization chamber dosimetry protocol and uniform conversion factors will establish agreement on proton absorbed dose to approximately 1.5%, consistent with that which has been observed in high-energy photon and electron dosimetry.

Calibration

Characterization of dose distribution in radiation therapy plans.

As a method of considering only significant radiation doses to different tissues, the ICRU Report 50 recommends taking the dose given to a significant tissue volume (minimum diameter greater then 15 mm) instead of choosing a single, potentially insignificant, voxel value. In order to find this significant volume, we have adapted an emission imaging analysis method to radiation therapy planning. The resulting method finds and characterizes the dose distribution in the volumes of interest in a way that includes spatial arrangement. The data can be used to signal significant hot or cold volumes in the dose plan and to score the plans based on significant dose to the tissues.

Humans

The calibration of CT Hounsfield units for radiotherapy treatment planning.

Computer tomographic (CT) scans are used to correct for tissue inhomogeneities in radiotherapy treatment planning. In order to guarantee a precise treatment, it is important to obtain the relationship between CT Hounsfield units and electron densities (or proton stopping powers for proton radiotherapy), which is the basic input for radiotherapy planning systems which consider tissue heterogeneities. A method is described to determine improved CT calibrations for biological tissue (a stoichiometric calibration) based on measurements using tissue equivalent materials. The precision of this stoichiometric calibration and the more usual tissue substitute calibration is determined by a comparison of calculated proton radiographic images based on these calibrations and measured radiographs of a biological sample. It has been found that the stoichiometric calibration is more precise than the tissue substitute calibration.

Humans

The 200-MeV proton therapy project at the Paul Scherrer Institute: conceptual design and practical realization.

The new proton therapy facility is being assembled at the Paul Scherrer Institute (PSI). The beam delivered by the PSI sector cyclotron can be split and brought into a new hall where it is degraded from 590 MeV down to an energy in the range of 85-270 MeV. A new beam line following the degrader is used to clean the low-energetic beam in phase space and momentum band. The analyzed beam is then injected into a compact isocentric gantry, where it is applied to the patient using a new dynamic treatment modality, the so-called spot-scanning technique. This technique will permit full three-dimensional conformation of the dose to the target volume to be realized in a routine way without the need for individualized patient hardware like collimators and compensators. By combining the scanning of the focused pencil beam within the beam optics of the gantry and by mounting the patient table eccentrically on the gantry, the diameter of the rotating structure has been reduced to only 4 m. In the article the degrees of freedom available on the gantry to apply the beam to the patient (with two rotations for head treatments) are also discussed. The devices for the positioning of the patient on the gantry (x rays and proton radiography) and outside the treatment room (the patient transporter system and the modified mechanics of the computer tomograph unit) are briefly presented. The status of the facility and first experimental results are introduced for later reference.

Cyclotrons

Polar map or novel three-dimensional display technique for the improved detection of inferior wall myocardial infarction using tomographic radionuclide ventriculography.

Tomographic radionuclide ventriculography has the potential to be a significant improvement over conventional planar imaging. Although tomographic imaging can now be performed with relative ease, it is little used. This is most probably due to a perceived imbalance between potential clinical benefit and the extra complications of imaging. We investigated this matter by examining a series of 30 patients with isolated inferior or anterior myocardial infarction, identified by cardiac catheterization. Using either radionuclide imaging method, a significant wall motion abnormality was defined as matching (and appropriately located) phase and amplitude values outwith of two standard deviations from control values. These values were obtained from a series of 25 controls and represent construction values used to create a conventional polar map display. Overall detection rates for anterior myocardial infarction were 93 and 100% for planar and tomographic imaging, respectively (ns). For inferior myocardial infarction the rates were 7 and 93%, respectively (p < 0.001). Identical results were found using a novel three-dimensional method of displaying wall motion abnormalities. Tomography is therefore superior to planar imaging for the detection of inferior myocardial infarction but similar to planar imaging for the detection of anterior myocardial infarction.

Cardiac Catheterization

Three-dimensional endoscopic imaging for minimal access surgery.

Three-dimensional endoscopic imaging (3DEndoImaging) is a significant technological advance and has the potential to make minimal access surgery (MAS) easier, quicker, less prone to error and more applicable to advanced procedures. Surgeons involved in MAS will need to have a working knowledge of 3DEndoImaging. This article will enable surgeons to compare stereo systems and evaluate which system would best suit their needs. This paper explains why stereo imaging is important and describes the methods by which stereo images can be produced. The technology required is discussed in simple terms. The types of stereo systems are described and important operational and maintenance issues discussed. Task analysis studies showing significant improvement in performance in stereo are presented. These studies simulated accurately positioning an instrument and threading a small diameter solder lug.

Endoscopes