PubMed Health⌕ Search

Biomedical subjects

A Lorente

Publications and source records attributed to A Lorente.

At least 19 recordsLinked to original sources

Artificial neural networks in neutron dosimetry.

An artificial neural network (ANN) has been designed to obtain neutron doses using only the count rates of a Bonner spheres spectrometer (BSS). Ambient, personal and effective neutron doses were included. One hundred and eighty-one neutron spectra were utilised to calculate the Bonner count rates and the neutron doses. The spectra were transformed from lethargy to energy distribution and were re-binned to 31 energy groups using the MCNP 4C code. Re-binned spectra, UTA4 response matrix and fluence-to-dose coefficients were used to calculate the count rates in the BSS and the doses. Count rates were used as input and the respective doses were used as output during neural network training. Training and testing were carried out in the MATLAB environment. The impact of uncertainties in BSS count rates upon the dose quantities calculated with the ANN was investigated by modifying by +/-5% the BSS count rates used in the training set. The use of ANNs in neutron dosimetry is an alternative procedure that overcomes the drawbacks associated with this ill-conditioned problem.

Algorithms↗

Evidence for strange-quark contributions to the nucleon's form factors at Q2=0.108 (GeV/c)2.

We report on a measurement of the parity violating asymmetry in the elastic scattering of polarized electrons off unpolarized protons with the A4 apparatus at MAMI in Mainz at a four momentum transfer value of Q(2)=0.108 (GeV/c)(2) and at a forward electron scattering angle of 30 degrees p)=[-1.36+/-0.29(stat)+/-0.13(syst)]x10(-6). The expectation from the standard model assuming no strangeness contribution to the vector current is A(0)=(-2.06+/-0.14)x10(-6). We have improved the statistical accuracy by a factor of 3 as compared to our previous measurements at a higher Q2. We have extracted the strangeness contribution to the electromagnetic form factors from our data to be G(s)(E)+0.106G(s)(M)=0.071+/-0.036 at Q(2)=0.108 (GeV/c)(2). We again find the value for G(s)(E)+0.106G(s)(M) to be positive, this time at an improved significance level of two sigma.

Journal Article↗

Measurement of strange-quark contributions to the nucleon's form factors at Q(2) = 0.230 (GeV/c)(2).

We report on a measurement of the parity-violating asymmetry in the scattering of longitudinally polarized electrons on unpolarized protons at a Q2 of 0.230 (GeV/c)(2) and a scattering angle of theta (e) = 30 degrees - 40 degrees. Using a large acceptance fast PbF2 calorimeter with a solid angle of delta omega = 0.62 sr, the A4 experiment is the first parity violation experiment to count individual scattering events. The measured asymmetry is A(phys)=(-5.44+/-0.54(stat)+/-0.26(sys))x10(-6). The standard model expectation assuming no strangeness contributions to the vector form factors is A(0) = (-6.30+/-0.43) x 10(-6). The difference is a direct measurement of the strangeness contribution to the vector form factors of the proton. The extracted value is G(s)(E) + 0.225G(s)(M) = 0.039+/-0.034 or F(s)(1) + 0.130F(s)(2) = 0.032+/-0.028.

Journal Article↗

Characteristics of the neutron field of the facility at DIN-UPM.

A new source facility (241Am-Be) has been installed in a bunker-type room of large dimensions. To characterise the neutron fields in the facility, detailed calculations have been made with MCNP-4C, showing the different components of the neutron radiation reaching the reference points (direct, inscattered, backscattered). The contribution from neutrons scattered in the walls to the total ambient dose equivalent remains reasonably low (<10%) in the reference points. Additionally, spectra measurements have been performed with a Bonner spheres spectrometer with a 6LiI(Eu) scintillator (0.4 phi x 0.4 cm2), UTA4 response matrix and BUNKIUT unfolding code. The calculated and experimentally obtained spectra are compared, with small differences found in the epithermal and thermal region, attributable to the concrete composition used in the calculations. The H*(10) rate has been determined from the spectra, and then compared to the reading of an active dosemeter (LB6411), with differences found lower than 8%.

Algorithms↗

Response components of LiF:Mg,Ti around a moderated Am-Be neutron source.

The responses of TLD-1010, TLD-700 and TLD-600 thermoluminescence dosemeters to the radiation field inside a water tank enclosing an isotopic 241Am-Be neutron source are analysed. Separate contributions coming from thermal neutrons, neutrons with energies above thermal and gamma rays to the total response of the three types of TLD are obtained. This is accomplished by assuming that the gamma responses for materials with different 6Li enrichments are identical and that the neutron response of TLD-700 is negligible compared to TLD-100 and TLD-600. The last assumption is tested by Monte Carlo simulations of the neutron energy spectrum at the points where the TLDs are irradiated.

Americium↗

Characterization of the visual performance with soft daily wear disposable contact lenses.

We investigate the visual performance associated with adaptation to a daily wear soft contact lens on the human eye. For this purpose, we used four parameters, one of which was an objective parameter, while the rest were subjective parameters. The objective parameter was a single quality parameter, a Merit function (Mf) derived from the modulation transfer function (MTF) of the overall [eye + contact lens] system The subjective parameters were the visual acuity (VA), the contrast sensitivity function (CSF) and the standard adaptation criterion of Terry et al. (1993). The normality criterion for the MTF was determined by evaluating the fluctuations of the Mf over a day in five emmetropic observers. Fluctuations with no statistically significant differences in the merit function (p > 0.05) and their standard deviation (8%) defined our standard criterion. The CSF and the VA were similarly measured (for emmetropic observers). The results obtained with emmetropic observers allowed us to establish a standard criterion for the evaluation parameters we propose. When this criterion is applied to daily soft wear disposable contact lenses, their performance proves to be good, since both the objective (MTF) and the subjective parameters (CSF, VA, adaptation criterion) always lie within the range defined by our criterion.

Adaptation, Physiological↗

Influence of the tear film on optical quality of the eye.

The optical quality of the tear film of the eye was tested by measuring the retinal image before and after the break-up time (BUT). An objective method was used based on the evaluation of the retinal image of a point test projected onto the fovea. The loss of an entire tear film would result in a decrease in the optical quality because of corneal irregularities and the formation of an irregular tear lens after the BUT. Our results confirm the expected loss both of non-contact lens wearers and contact lens wearers. Also, the fact that the optical deterioration found after the BUT is greater for contact lens wearers confirms that soft contact lens wear produces a disruption of the tears.

Journal Article↗

Contact lenses: do they really change the optical performance?

In this investigation the quality of two types of optical correction, hydrogel contact lenses and ophthalmic lenses, was compared by measuring the modulation transfer function (MTF) of the correcting lens plus visual optics system using an objective method. A merit function was defined in order to allow the direct comparison between the optical performance with the two corrections. A study on 10 subjects was undertaken, measuring the MTF of both corrections by using the double pass method. The results show that the optical quality of contact lenses was higher than that with ophthalmic lenses. The contrast sensitivity function (CSF) and visual acuity (VA) were determined as subjective parameters of visual performance.

Journal Article↗

Standard criterion for fluctuations of modulation transfer function in the human eye: application to disposable contact lenses.

It is well known that the modulation transfer function (MTF) characterizes the optical quality of the eye. Recently, some objective techniques have been introduced in order to measure this function in vivo. These techniques could be employed to display the temporal fluctuations of the eye + compensation system and to isolate the effect of the compensation element provided that the standard fluctuations for a normal observer were known. In this work we carry out a study of the MTF of the human eye over a long period of time to quantify the standard fluctuations of the retinal image quality and to establish a standard criterion of normality. We have defined a single quality parameter from each measured MTF to simplify the analysis of the results. We have evaluated this merit function on normal observers three times a day for one month. As expected, random deviations from the mean value of the merit function have been obtained, although fluctuations with no statistical differences of the merit function (P value from ANOVA test P > 0.01) and the standard deviation of these fluctuations (5%) can be chosen as a standard criterion. We have used this result to study the behaviour of a time-varying compensation element: a disposable contact lens. The study of the eye + contact lens system has been carried out with four types of disposable contact lenses for one month. In spite of their generally good behaviour, statistically significant differences from the standard pattern can be observed. This superimposed continuous fluctuation can be due to lens-dependent processes.

Contact Lenses↗