PubMed Health⌕ Search

Biomedical subjects

A Lucke

Publications and source records attributed to A Lucke.

13 recordsLinked to original sources

[Comparison of different review displays with respect to the detection of low-contrast details in digital radiographs].

PURPOSE: Assessment of low-contrast details in digital radiographs on different review displays (RD). MATERIALS AND METHODS: 20" flat screen panels (RD1: standard color LCD-TFT, RD2: monochrome LCD-TFT for radiological reading, RD1*: RD1 with optional image inversion; 205 cd/m (2) luminance, respectively) were evaluated. At 30 lx ambient lighting, 10 radiologists gradually increased the contrast (constant steps) for both a homogeneous picture and a cutout of a thorax radiography of n = 480 simulated nodules until they became recognizable. RESULTS: In the case of bright nodules on an anthropomorphic background, the use of image inversion produced significantly better results. No other significant differences were detected. CONCLUSION: Provided that the working environment is not bright, the results suggest that low-cost RD can be used for the recognition of low-contrast details in radiographies of the chest. Further studies including more display models are necessary. Among different ambient lighting and luminance settings, these studies should include a closer analysis of the special features of digital systems such as brightness/contrast adaptation, picture enlargement (zoom shot), and image inversion.

Equipment Design↗

[PACS: storage and retrieval of digital radiological image data].

BACKGROUND: Efficient handling of both picture archiving and retrieval is a crucial factor when new PACS installations as well as technical upgrades are planned. MATERIALS AND METHODS: For a large PACS installation for 200 actual studies, the number, modality,and body region of available priors were evaluated. In addition, image access time of 100 CT studies from hard disk (RAID), magneto-optic disk (MOD), and tape archives (TAPE) were accessed. RESULTS: For current examinations priors existed in 61.1% with an averaged quantity of 7.7 studies. Thereof 56.3% were within 0-3 months, 84.9% within 12 months, 91.7% within 24 months, and 96.2% within 36 months. On average, access to images from the hard disk cache was more than 100 times faster then from MOD or TAPE. CONCLUSION: Since only PACS RAID provides online image access, at least current imaging of the past 12 months should be available from cache. An accurate prefetching mechanism facilitates effective use of the expensive online cache area. For that, however, close interaction of PACS, RIS, and KIS is an indispensable prerequisite.

Database Management Systems↗

[Possibilities for workflow optimization in radiology departments beyond RIS and PACS].

Technological progress and the rising cost pressure on the healthcare system have led to a drastic change in the work environment of radiologists today. The pervasive demand for workflow optimization and increased efficiency of its activities raises the question of whether by employment of electronic systems, such as RIS and PACS, the potentials of digital technology are sufficiently used to fulfil this demand. This report describes the tasks and structures in radiology departments, which so far are only insufficiently supported by commercially available electronic systems but are nevertheless substantial. We developed and employed a web-based, integrated workplace system, which simplifies many daily tasks of departmental organization and administration apart from well-established tasks of documentation. Furthermore, we analyzed the effects exerted on departmental workflow by employment of this system for 3 years.

Database Management Systems↗

[Digital teaching archive. Concept, implementation, and experiences in a university setting].

Film-based teaching files require a substantial investment in human, logistic, and financial resources. The combination of computer and network technology facilitates the workflow integration of distributing radiologic teaching cases within an institution (intranet) or via the World Wide Web (Internet). A digital teaching file (DTF) should include the following basic functions: image import from different sources and of different formats, editing of imported images, uniform case classification, quality control (peer review), a controlled access of different user groups (in-house and external), and an efficient retrieval strategy. The portable network graphics image format (PNG) is especially suitable for DTFs because of several features: pixel support, 2D-interlacing, gamma correction, and lossless compression. The American College of Radiology (ACR) "Index for Radiological Diagnoses" is hierarchically organized and thus an ideal classification system for a DTF. Computer-based training (CBT) in radiology is described in numerous publications, from supplementing traditional learning methods to certified education via the Internet. Attractiveness of a CBT application can be increased by integration of graphical and interactive elements but makes workflow integration of daily case input more difficult. Our DTF was built with established Internet instruments and integrated into a heterogeneous PACS/RIS environment. It facilitates a quick transfer (DICOM_Send) of selected images at the time of interpretation to the DTF and access to the DTF application at any time anywhere within the university hospital intranet employing a standard web browser. A DTF is a small but important building block in an institutional strategy of knowledge management.

Computer-Assisted Instruction↗

[Recommendations for the selection of storage media for archiving digital radiological image data based on the comparison of retrieval times at different PACS archive levels].

PURPOSE: Recommendations for archiving digital radiological image data based on the comparison of retrieval times for different PACS archive levels. MATERIALS AND METHODS: For a large PACS installation (Agfa Impax, Release 4.1), image retrieval times for radiological standard examinations (chest radiographs with 2, MRI with 250, CT with 100 and 1000 images; n = 120, each) from hard disk array, magneto-optical disk (MOD), and magnetic tape archives (TAPE) were examined in high and low network traffic load. RESULTS: Even large CT examinations (1000 images) were available from hard disk arrays within 4.0 +/- 0.8 s, smaller studies within 1.8 +/- 0.3 s. Radiographic image retrieval from MOD (30 +/- 4.7 s) was more then 50 % faster than from TAPE. For typical cross-sectional studies, the velocity gain amounted to 19 %. For both technologies, no significant difference was found for large CT examinations (651 +/- 144 s). For high and low network traffic load scenarios, image retrieval times from hard disk, MOD, and TAPE archives increased by 87 %, 7 %, and 22 %, respectively. CONCLUSION: Hard disk arrays are specifically suited as departmental intermediate storage media because they allow fast access to current and previous examinations within a short time. Performance properties enable both MOD and TAPE systems to serve as long-term archives. However, MOD archives are less flexible in the expansion of storage capacity and at present the medium costs per memory unit are about 2 - 3 times higher than for tape archives. The use of existing MOD-archives may be adequate as intermediate archives. For new PACS installations or system expansions, however, it is recommended to combine a sufficiently large local data memory (RAID) with data storage on tape archives outside the radiological unit that can be used by other departments as well. Future development of hard disk prices will show whether archiving for the whole data retention period may be handled by RAID systems. In any case, prefetching problems and waiting periods for demanded pre-studies would not occur any more.

Humans↗

IT services in a completely digitized radiological department: value and benefit of an in-house departmental IT group.

To analyze the benefit of a departmental IT group in comparison to support by hospital IT groups or system manufacturers in a completely digitized radiological department. The departmental IT group comprises a fulltime IT specialist, two student assistants and four clinical employees participating 1 day/week. For 18 months IT problems were quantified and specified according to urgency, responsibility and affected system by use of an intranet-based reporting system. For each IT service provider the performance and duration of problem solution was evaluated. In 18 months 3,234 IT problems emerged. 88.7% were solved by the departmental IT group. In 474 cases (14.7%) a solution within 2 h was required. The departmental IT group solved 35.8% within 30 min, system manufacturers needed 18 h 38 min in mean. The departmental IT group solved 90.2% of the problems within a time limit. System manufacturers met the limit in 60.1% with a mean duration of 7 days 21 h. In 6.7% of the cases, support by system manufacturers was indispensable. A considerable proportion of IT problems in completely digitized radiological departments can be solved by a departmental IT group, providing a fast and cost-efficient first-level IT support with effective prevention of major breaks in the workflow. In a small number of cases support by system manufacturers remains necessary.

Computer Communication Networks↗

Biodegradable poly(D,L-lactic acid)-poly(ethylene glycol)-monomethyl ether diblock copolymers: structures and surface properties relevant to their use as biomaterials.

To obtain biodegradable polymers with variable surface properties for tissue culture applications, poly(ethylene glycol) blocks were attached to poly(lactic acid) blocks in a variety of combinations. The resulting poly(D,L-lactic acid)-poly(ethylene glycol)-monomethyl ether (Me.PEG-PLA) diblock copolymers were subject to comprehensive investigations concerning their bulk microstructure and surface properties to evaluate their suitability for drug delivery applications as well as for the manufacture of scaffolds in tissue engineering. Results obtained from 1H-NMR, gel permeation chromatography, wide angle X-ray diffraction and modulated differential scanning calorimetry revealed that the polymer bulk microstructure contains poly(ethylene glycol)-monomethyl ether (Me.PEG) domains segregated from poly(D,L-lactic acid) (PLA) domains varying with the composition of the diblock copolymers. Analysis of the surface of polymer films with atomic force microscopy and X-ray photoelectron spectroscopy indicated that there is a variable amount of Me.PEG chains present on the polymer surface, depending on the polymer composition. It could be shown that the presence of Me.PEG chains in the polymer surface had a suppressive effect on the adsorption of two model peptides (salmon calcitonin and human atrial natriuretic peptide). The possibility to modify polymer bulk microstructure as well as surface properties by variation of the copolymer composition is a prerequisite for their efficient use in the fields of drug delivery and tissue engineering.

Biocompatible Materials↗

Modulation of marrow stromal cell function using poly(D,L-lactic acid)-block-poly(ethylene glycol)-monomethyl ether surfaces.

The adhesion of marrow stromal osteoblasts and the adsorption of fetal bovine serum (FBS) proteins to end-capped poly(D,L-lactic acid) 50:50 (PLA50) of molecular weight 17,000 (PLA5017), non-end-capped PLA50 of molecular weight 11,000 (PLA5011h), and a diblock copolymer made of poly(ethylene glycol)-monomethyl ether of molecular weight 5,000 and PLA50 of molecular weight 20,000 (Me. PEG5-PLA20) were investigated. Cell attachment and proliferation on both PLA50 polymers were equally good. The block copolymer did not allow the proliferation of cells. However, the attached cells were highly differentiated and metabolically active in contrast to the cells on PLA50. Moreover, surface analysis studies using electron spectroscopy revealed that FBS proteins adsorbed well from aqueous solutions to the PLA50 surfaces while they adsorbed substantially less to the block copolymer. These results suggest that Me.PEG-PLA block copolymers may be used to regulate protein adsorption and, therefore, cell adhesion by varying the block composition of the copolymer.

Adsorption↗