Intrinsic positive end-expiratory pressure in mechanically ventilated patients with and without tidal expiratory flow limitation.

OBJECTIVE: To assess static intrinsic positive end-expiratory pressure (PEEPi,st) and expiratory flow limitation (FL) in 32 consecutive mechanically ventilated patients with acute respiratory failure (ARF), using a commercial ventilator with an incorporated device that allows the application of a negative expiratory pressure (NEP). DESIGN: Prospective clinical study. SETTING: Multidisciplinary intensive care unit of a university hospital. PATIENTS: Thirty-two consecutive ventilated patients with ARF of various etiologies. INTERVENTIONS: Evaluation of respiratory mechanics, PEEPi,st, and FL from pressure, flow, and volume traces provided by the ventilator. MEASUREMENTS: Peak airway pressure, PEEPi,st, dynamic elastance, and interrupter resistance were measured in relaxed patients in a supine position. Comparison of tidal flow-volume curves before and during the application of an NEP of 5 cm H2O was used to assess tidal expiratory FL. RESULTS: Twelve of 32 patients studied exhibited tidal expiratory FL, which was detected by the absence of increase in expiratory flow despite application of an NEP over the entire or part of the baseline expiratory flow-volume curve. All patients exhibited PEEPi,st, which amounted to 1.2 +/- 0.9 cm H2O (mean +/- SD) in the 20 non-FL patients and 7.1 +/- 2.8 cm H2O in the 12 FL patients (p < 0.00001). The majority of patients with ARF resulting from underlying lung disease (11 of 13) had FL and a PEEPi,st > 4 cm H2O, whereas in patients with ARF of extrapulmonary origin, PEEPi,st was always < 4 cm H2O and only one grossly obese patient exhibited FL. Based on multiple regression analysis, in non-FL patients, PEEPi,st correlated significantly only with minute ventilation, whereas in FL patients PEEPi,st correlated significantly with peak airway pressure. CONCLUSIONS: Because all the patients exhibited PEEPi,st and 12 of 32 patients (38%) also had FL, the authors conclude that the assessment of these variables at the bedside could provide useful information concerning respiratory mechanics in mechanically ventilated patients.

Adolescent↗

Expiratory flow limitation and intrinsic positive end-expiratory pressure at zero positive end-expiratory pressure in patients with adult respiratory distress syndrome.

It has been suggested that in patients with adult respiratory distress syndrome (ARDS), intrinsic positive end-expiratory pressure (PEEPi) is generated by a disproportionate increase in expiratory flow resistance. Using the negative expiratory pressure (NEP) technique, we assessed whether expiratory flow limitation (EFL) and PEEPi were present at zero PEEP in 10 semirecumbent, mechanically ventilated ARDS patients. Because bronchodilators may decrease airway resistance, we also investigated the effect of nebulized salbutamol on EFL, PEEPi, and respiratory mechanics in these patients, and in seven patients we measured the latter variables in the supine position as well. In the semirecumbent position, eight of the 10 ARDS patients exhibited tidal EFL, ranging from 5 to 37% of the control tidal volume (VT), whereas PEEPi was present in all 10 subjects, ranging from 0.4 cm H(2)O to 7.7 cm H(2)O. The onset of EFL was heralded by a distinct inflection point on the expiratory flow-volume curve, which probably reflected small-airway closure. Administration of salbutamol had no statistically significant effect on PEEPi, EFL (as %VT), or respiratory mechanics. EFL (%VT) and PEEPi were significantly higher in the supine position than in the semirecumbent position, whereas the other respiratory variables did not change. Our results suggest that in the absence of externally applied PEEP, most ARDS patients exhibit EFL associated with small-airway closure and a concomitant PEEPi.

Adult↗

Vital signs monitoring from home with open systems.

This study investigates the applicability of a novel codification scheme based on two healthcare informatics standards (namely the VITAL (ENV 13734) and DICOM Sup. 30 Waveform Interchange) in addressing the robust interchange of waveform and medical data in remote healthcare applications. To further address system validation and clinical acceptance issues, pilots were set-up between home-monitoring stations and a hospital-based telemedicine consultation center. The pilots focused in assessing applicability, technical feasibility and performance of the proposed codification scheme based on the two standards. This paper presents the system and services requirements as studied for a home-care application, the design goals for the preservation of security stature, the practical issues of validation and the results of integrating these codification schemes into a commercial patient connected device.

Computer Systems↗

Brain eigenfrequency shifting as a sensitive index of cerebral compliance in an experimental model of epidural hematoma in the rabbit: preliminary study.

OBJECTIVE: To verify brain eigenfrequency shifting after the occurrence of a lesion producing mass effect into the cranial vault. DESIGN: Experimental animal study. SETTING: Laboratory of experimental surgery affiliated with a university critical care department. SUBJECTS: Six adult male New Zealand white rabbits. INTERVENTIONS: A Camino ICP monitor was placed in the parenchyma, and a 5-Fr balloon-tipped catheter and accelerometer were placed into the epidural space. MEASUREMENTS: Before and after the introduction of successive 0.1-mL increments of autologous blood into the balloon, intracranial pressure (ICP) was recorded along with the accelerometer signal obtained during free vibration of the skull triggered by a calibrated hammer. Fast Fourier transformation of the digitized signal provided the eigenfrequency spectrum. The eigenfrequency showing the sharpest decrease after the initial 0.1-mL volume addition was considered as the best frequency, and its variation in response to subsequent 0.1-mL increments represents the brain eigenfrequency shifting. MAIN RESULTS: Brain eigenfrequency shifting to lower values occurs for small blood volume increments (up to 0.2 mL). When volume addition becomes >0.3 mL, brain eigenfrequency shifting to higher values is exhibited. The decrease in best frequency after the initial introduction of 0.1 mL is statistically significant (p = .003), in a range of volume in which no significant intracranial pressure difference appears. The respective variation of ICP is explained using a quadratic curve. For volumes of 0 to 0.1 mL, the change in ICP is not statistically significant (p = .08). CONCLUSIONS: Changes of the brain's physical characteristics by mass addition in the cranial vault can be expressed by brain eigenfrequency shifting. The method seems advantageous because it reliably detects mass additions at low levels where no ICP change occurs. Additionally, it provides serial measurements, and it is less invasive than the currently used methods for intracranial compliance.

Animals↗

A decision support software package for medical treatment of I.C.U. patients.

Critically ill patients admitted in I.C.U. often have multiple complicated problems which necessitate the use of a large number of drugs. The multiple potential interactions between substances and underlying pathologies as well as between substances themselves, obviate the need for a decision support system. We therefore developed a software package for medical treatment support in I.C.U. environment which is based on Microsoft Visual Basic 3.0 and it is organised around the commercially available RDBMS Access 2.0. The database consist of: a) all available substances, b) all generic names of medications available in Greece for each substance, c) incompatibilities (2,300 cases), d) interactions (50,000 cases) and e) cost information for each drug. This system assures the safety of the administered treatment, helps to adjust the dose according to the situation of each patient (anthropometric data, laboratory result, prognostic/severity score e.t.c.) and screens for possible interactions and incompatibilities between the administered drugs. It could also be used for education, treatment algorithms application and it will serve cost-reduction policy. It is a useful and powerful tool for ICU staff which does not impose additional work to the daily practice routine and it is currently under evaluation in clinical settings.

Adverse Drug Reaction Reporting Systems↗

Estimation of frequency-dependent attenuation based on parametric spectral analysis and correlation lags of the demodulated echo signal.

Two new methods for estimating frequency-dependent attenuation are proposed which improve the compromise between the estimation variance of this parameter and the analyzed tissue volume: 1) parametric spectral estimation of the demodulated signal, based on fast Kalman filtering (ARC), 2) implementation of a new mean frequency estimator derived from all the available autocorrelation lags (ACn) of the demodulated signal. Both methods are applied to simulated echo signals. The results are compared to those of other already existing estimators. Both ARC and ACn methods provide equivalent results and a better estimation of attenuation (accuracy ranging from 1.3 to 8%) than the previous methods do (accuracy ranging from 4 to 66%), for analysis windows ranging from 1.5 to 20 microseconds.

Ultrasonics↗