Apparent change in cardiac geometry during single-photon emission tomography thallium-201 acquisition: a complex phenomenon.

We investigated the frequency and extent of changes in heart position and geometry independent of body motion during stress single-photon emission tomography (SPET) thallium-201 myocardial perfusion imaging. Following an exercise treadmill test, patients had a 22.1-min SPET acquisition which was followed immediately by a static image acquisition for 1 min with the camera position identical to the first view of the SPET study. Point sources were placed on the body to monitor patient motion. Cardiac motion was assessed by an approach which mimicked a cross-correlation technique applied to cardiac count profiles along the horizontal and vertical directions from the first view of the SPET study and the static image. A large percentage (87.5%) of cases had some degree of horizontal or vertical motion. Pixel shifts in cardiac position of > or = 2 pixels (12 mm) occurred in 60% of patients. In 37% of patients who moved the cardiac motion was consistent with simple translation of the heart and thus amenable to correction using proposed SPET motion-correction programs. The peak heart rate achieved during stress and the ratio of the heart rate immediately before SPET acquisition to the resting heart rate were determined to be independent predictors of patient motion during SPET acquisition. Cardiac motion changes were minimal at (13.3 +/- 2.2) min after cessation of exercise. The implications of these findings for the accuracy of SPET 201Tl require further investigation.

Algorithms↗

Comparison of single-photon emission computed tomographic (SPECT) myocardial perfusion imaging with thallium-201 and technetium-99m sestamibi in dogs.

OBJECTIVES: The purpose of the present study was to compare single-photon emission computed tomographic (SPECT) myocardial images of technetium-99m (Tc-99m) sestamibi and thallium-201 (Tl-201) isotopes in the same dog undergoing partial coronary occlusion during pharmacologic vasodilation. BACKGROUND: To date, no controlled study has been reported comparing SPECT Tc-99m sestamibi with SPECT Tl-201 imaging during stress with anatomic and physiologic standards. METHODS: Mongrel dogs were anesthetized with chloralose and instrumented to record left anterior descending coronary blood flow and aortic pressure. Partial coronary occlusion with a hydraulic cuff reduced coronary vascular conductance, which is equal to the coronary blood flow normalized to aortic pressure during peak vasodilation with intravenous adenosine. Each dog received 5 mCi of Tl-201, then 30 mCi of Tc-99m sestamibi during partial coronary occlusion at peak vasodilation. Tomographic myocardial imaging was performed in a 180 degrees anterior arc scan for 33.5 min, first with Tl-201, and later, without moving the dog, for 33.5 min with Tc-99m sestamibi. Postmortem staining defined the region underperfused because of its dependence on the artery that was partially occluded. RESULTS: In seven dogs with moderate reduction in coronary blood flow, coronary vascular conductance decreased with partial coronary occlusion (47 +/- 12%) during Tl-201 imaging and (47 +/- 8%, p = NS) during Tc-99m sestamibi imaging. The underperfused region was 23.9 +/- 6.4% of total left ventricular mass. Counts in the defects were 39% higher (0.86 +/- 0.08 of normal counts) for Tc-99m sestamibi than for Tl-201 (0.64 +/- 0.09 of normal counts, p < 0.001), and the defect on SPECT Tc-99m sestamibi images occupied only a fraction (0.37 +/- 0.30) of the area of the defect on the Tl-201 images of the same dog. Bull's-eye displays constructed from the pathologic slices showed that the Tl-201 defect size was closer to the underperfused region of the left ventricular mass determined pathologically than was the Tc-99m sestamibi defect size. In four additional dogs a severe, near total coronary occlusion was created during Tl-201 and Tc-99m sestamibi administration. In these dogs, similar defect contrast (0.55 +/- 0.12 vs. 0.62 +/- 0.09, p = NS) and areas (0.18 +/- 0.07 vs. 0.18 +/- 0.11, p = NS) were observed with Tl-201 and Tc-99m sestamibi, respectively. CONCLUSIONS: Tomographic myocardial imaging with Tc-99m sestamibi during moderately severe partial coronary occlusion underestimated the area of the defect relative to Tl-201 or to the pathologic reference standard in dogs. Defect contrast was sharper with tomographic myocardial Tl-201 than with tomographic myocardial Tc-99m sestamibi during moderately severe partial coronary occlusion.

Adenosine↗