A M Abduljalil

Publications and source records attributed to A M Abduljalil.

At least 19 recordsLinked to original sources

High-resolution ultrahigh-field MRI of stroke.

BACKGROUND: Ultrahigh-field MRI at 8 T offers unprecedented resolution for imaging brain structures and microvasculature. OBJECTIVE: The aim of this study is to apply high-resolution MRI for stroke imaging and to characterize findings at 1.5 and 8 T. METHODS: Seventeen subjects with minor ischemic infarcts were studied using T2-weighted gradient echo (GE) and rapid acquisition with relaxation enhancement (RARE) images at 8 T with resolution up to 200 microm. In 10 subjects, T1- and T2-weighted fast spin echo (FSE) and fluid-attenuated inversion recovery (FLAIR) images were also acquired at 1.5-T MRI. RESULTS: The 8-T images showed infarcts as sharply demarcated areas of high-signal intensity (n=21) and revealed more infarctions than 1.5-T images (n=14) (P<.003). The low-signal intensity areas that surrounded infarctions were suggestive of hemosiderin deposits. The 8-T characteristics of microvessels terminating within the infractions were distinct from normal vasculature. The 8-T images revealed an angioma at the site of a second stroke, not apparent on 1.5-T images. CONCLUSIONS: Ultrahigh-field MRI at 8 T is feasible for stroke imaging. The 8-T MRI visualized infarcts and microvasculature with high resolution, revealing infarcts and vascular pathologies that were not apparent at 1.5 T.

Adult↗

Dielectric resonances and B(1) field inhomogeneity in UHFMRI: computational analysis and experimental findings.

B(1) Field inhomogeneity and the relative effects of dielectric resonances are analyzed within the context of ultra high field MRI. This is accomplished by calculating the electromagnetic fields inside spherical phantoms and within a human head model in the presence and absence of an RF coil. These calculations are then compared to gradient echo and RARE images, respectively. For the spherical phantoms, plane incident wave analyses are initially presented followed by full wave finite difference time domain (FDTD) calculations. The FDTD methods are then utilized to examine the electromagnetic interactions between the TEM resonator and an anatomically detailed human head model. The results at 340 MHz reveal that dielectric resonances are most strongly excited in objects similar in size to the human head when the conducting medium has a high dielectric constant and a low conductivity. It is concluded that in clinical UFHMRI, the most important determinants of B(1) field homogeneity consist of 1) the RF coil design, 2) the interaction between the RF coil, the excitation source and the sample, and finally 3) the geometry and electrical properties of the sample.

Brain↗

Effect of RF coil excitation on field inhomogeneity at ultra high fields: a field optimized TEM resonator.

In this work, computational methods were utilized to optimize the field produced by the transverse electromagnetic (TEM) resonator in the presence of the human head at 8 Tesla. Optimization was achieved through the use of the classical finite difference time domain (FDTD) method and a TEM resonator loaded with an anatomically detailed human head model with a resolution of 2 mm x 2 mm x 2 mm. The head model was developed from 3D MR images. To account for the electromagnetic interactions between the coil and the tissue, the coil and the head were treated as a single system at all the steps of the model including, numerical tuning and excitation. In addition to 2, 3, 4, 6, and 10-port excitations, an antenna array concept was utilized by driving all the possible ports (24) of a 24-strut TEM resonator. The results show that significant improvement in the circularly polarized component of the transverse magnetic field could be obtained when using multiple ports and variable phase and fixed magnitude, or variable phase and variable magnitude excitations.

Electromagnetic Fields↗

Analysis of B1 field profiles and SAR values for multi-strut transverse electromagnetic RF coils in high field MRI applications.

In this work, the B1 field homogeneity and specific absorption rate (SAR) values were evaluated for three high-frequency (340 MHz) radio frequency coils designed for use in human magnetic resonance imaging at 8 tesla. Eight-, 16-, and 24-strut transverse electromagnetic (TEM) resonators were examined both experimentally and with the finite difference time domain numerical method. It was observed that increasing the number of TEM elements acted to lower the maximal achievable frequency of the coil and to increase the experimental complexities associated with tuning and matching. In addition, it is demonstrated from experiment and numerical analysis that the circularly polarized component of the B1 (B1+) field homogeneity in the head improved most from 8- to 16-strut coils. Numerical analysis revealed little difference in terms of SAR distribution between these coils; however, stronger tissue/coil coupling and consequently higher SAR peak values were obtained for the 8-strut case.

Algorithms↗

Human rapid acquisition with relaxation enhancement imaging at 8 T without specific absorption rate violation.

A standard fast imaging sequence, rapid acquisition with relaxation enhancement (RARE), has been applied to human magnetic resonance at 8 T. RARE is known for its speed, good contrast and high RF power content. Highly T2 weighted images, the hallmark of RARE imaging, were acquired from the human brain. It is demonstrated that while T2 values may be reduced at 8 T, high quality RARE images could still be acquired at this field strength. Most importantly however, it is demonstrated that RARE images could be acquired without violating specific absorption rate (SAR) guidelines. Since it is well known that T2 weighted images are of significant value in clinical diagnosis, the implementation of RARE at this field strength will provide ultra high field MRI (UHFMRI) with a valuable imaging protocol at this field strength without exceeding SAR limitations.

Brain↗

MDEFT imaging of the human brain at 8 T.

T1-weighted images of the human brain obtained with the MDEFT sequence at 8 T are presented. These images are characterized by an excellent contrast and good signal to noise ratio. Importantly, results were obtained with adiabatic spin inversion and demonstrate that such pulses can be used even in the ultra high frequency (> 300 MHz) range. It is thus possible to obtain high quality results at this field strength without violating SAR guidelines.

Brain↗

High signal-to-noise FLASH imaging at 8 Tesla.

A radio frequency (RF) and gradient spoiled fast low angle shot technique was used to acquire images from the human brain at 8 Tesla. The resulting FLASH images, obtained with a 17 degrees nutation, a 70 ms repetition time, and a 17 ms echo time, displayed an average signal-to-noise ratio (SNR) of 220:1 (slice thickness 2.2 mm, field-of-view 24 cm, matrix 256 x 128). These images were compared with images obtained at 1.5 Tesla using identical parameters yielding a signal-to-noise of less than 10:1. As such, the 8 Tesla images display a remarkable improvement in SNR with increasing field strength. The images also show little evidence of susceptibility distortion, chemical shift, or RF penetration limitations.

Brain↗

Cognitive, cardiac, and physiological safety studies in ultra high field magnetic resonance imaging.

A systematic analysis of the effect of an 8.0 tesla static magnetic field on physiological and/or cognitive function is presented in the normal volunteer and in the swine. A study of ten human subjects revealed no evidence of detectable changes in body temperature, heart rate, respiratory rate, systolic pressure, and diastolic blood pressure after 1 hour of exposure. In addition, no cognitive changes were detected. Important ECG changes were noted which were related both to the position of the subject in the magnet and to the absolute strength of the magnetic field. As such, the ECG tracing at 8 tesla was not diagnostically useful. Nonetheless, all subjects exhibited normal ECG readings both before and following exposure to the 8 tesla field. Cardiac function was also examined in detail in the swine. No significant changes in body temperature, heart rate, left ventricular pressure, left ventricular end diastollic pressure, time rate of change of left ventricular pressure, myocardial stiffness index, cardiac output, systolic volume, troponin, and potassium levels could be detected following 3 h of exposure to a field strength of 8.0 tesla. It is concluded that no short term cardiac or cognitive effects are observed following significant exposure to a magnetic field of up to 8.0 tesla.

Animals↗

Human magnetic resonance imaging at 8 T.

In this work, we present the first human magnetic resonance image (MRI) obtained at ultrahigh field strengths (8 T). We demonstrate that clinical imaging will be possible at 8 T and that reasonable quality head images can be obtained at this field strength. Most importantly, we emphasize that the power required to excite the spins at 8 T is much lower than had previously been predicted by the nuclear magnetic resonance theory. A 90 degree pulse in the head at 8 T requires only approximately 0.085 J of energy (90 W for a 2-lobe 4 ms sinc pulse). Based on measurements at 4 T, 1-2 J of energy should have been utilized to achieve a 90 degree excitation at 8 T. The fact that the energy required for spin excitation at 8 T is much lower than predicted by the NMR theory, will be extremely important to the viability of ultrahigh field imaging, since concerns related to power absorption and specific absorption rate (SAR) violations at ultrahigh field are alleviated. As such, it will be possible to utilize RF intensive pulse sequences and adiabatic spin excitation at 8 T without significant risk to the subject.

Brain↗

31P-NMR analysis of congestive heart failure in the SHHF/Mcc-facp rat heart.

31P-NMR was used to monitor myocardial bioenergetics in compensated and failing SHHF/MCC-fa(cp) (SHF) rat hearts. The SHHF/Mcc-fa(cp) (spontaneous hypertension and heart failure) rat is a relatively new genetic model in which all individuals spontaneously develop congestive heart failure, most during the second year of life. Failing SHF rat hearts displayed a pronounced decrease in resting PCr:ATP ratios (P<0.001), which was explained by a significant (P<0. 0001) drop in total creatine (47.2+/-3.1 nmol/mg protein) v age matched controls (106+/-3 nmol/mg protein). In end stage failure, NMR determined PCr was 2.9+/-0.1 micro mol/g wet weight under basal conditions. In contrast, 6- and 20-month-old controls and compensated SHFs had PCr values of 5.3+/-0.1, and 5.1+/-0.5 and 5. 1+/-0.2 micro mol/g wet weight. Both compensated and failing SHF hearts were metabolically compromised when the rate pressure product (RPP) was increased, as evidenced by an increase in Pi and a drop in PCr. Compensated SHF hearts, however, were able to increase rate pressure products (RRP, mmHg X beats/min) from 44.5+/-1.4 to 66.6+/-3. 4 K with dobutamine infusion, whereas hearts in end-stage failure were able to increase their RPP from baseline values of 27+/-4 K to only 37+/-7 K. The data indicate that a pronounced decline in PCr and total creatine signals the transition from compensatory hypertrophy to decompensation and failure in the SHF rat model of hypertensive cardiomyopathy.

Adenine Nucleotides↗

Alternate k-space sampling in EPI: compensation for T2* and adjustable T2 weighting.

In this work, preliminary results are described for a modification of the MBEST sampling scheme such that image resolution can be increased while preserving image contrast. In this new approach, a single spin-echo is used in sampling k-space. The basic idea relies on acquiring a conventional EPI image from the center of k-space and applying a pi pulse to permit the acquisition of the two outer edges of k-space. Using this new approach, it is possible to obtain an enhancement in EPI image resolution, while reducing the extent of T2* weighting. As a result, the resulting images possess reduced T2* contrast and suffer less signal loss from T2* effects such as spatial variations in susceptibility and field inhomogeneity.

Brain↗

Muscle torque in young and older untrained and endurance-trained men.

Plantar flexor torque was measured in 24 young (25 +/- 1.4 y) and older (62 +/- 2 y) untrained and endurance-trained men to test the hypothesis that age-associated declines in muscle function would be attenuated in older men who also endurance trained. Endurance-trained subjects averaged 7-9 h/wk of aerobic activity for 10-12 years. These subjects had not engaged in resistance training previously in the past 10 years. Plantar flexor torque was measured at velocities between 0 and 5.23 rads. s-1. In absolute terms, maximal isometric torque was 23% lower in older men compared to young men, regardless of their training status. On the other hand, relative measures of isometric strength (i.e., torque.muscle cross-sectional area-1 and torque.muscle volume-1) were similar in young and older men but were higher in trained than in untrained men. Isokinetic torque.muscle cross-sectional area-1 and torque.muscle volume-1 was greater at contraction velocities of 0.26-2.09 rads.s-1 for trained subjects. These data suggest that endurance training does not attenuate the age-associated loss of muscle mass or absolute strength. However, endurance training might reduce the extent of loss of relative strength because torque-muscle cross-sectional area-1 and torque.muscle volume-1 are greater in endurance-trained older men than in untrained older men.

Adult↗

Spatial localization with modified Fourier series windows. Application to the transmural 13C-nuclear magnetic resonance analysis of the in vivo myocardium.

RATIONALE AND OBJECTIVES: A modified Fourier Series Window (FSW) method is introduced that provides a simple, reasonably accurate, solution to spatial localization for layers in nuclear magnetic resonance (NMR) spectroscopy. This method was developed because signal originating from spins immediately adjacent to the coil plane can leak into standard FSW localized spectra obtained from more distal layers. METHODS: The B1 profile of the surface coil and a priori sample knowledge were used to generate modified FSW coefficients that largely compensate for contamination from proximal layers. These modified coefficients were used to acquire spatially localized spectra from a three-layered phantom containing inorganic phosphate, phosphocreatine, and pyrophosphate. Spatially localized spectra also were obtained from the open-chest canine myocardium. RESULTS: The modified Fourier Series Window approach was validated using a quality assurance phantom. This method was then applied to the transmural analysis of 13C-containing metabolites in the in vivo canine myocardium during 3-(13)C sodium pyruvate infusion (n = 10). In vivo NMR spectra were characterized by resonances corresponding to the C2, C3, and C4 carbons of glutamic acid and to endogenous triacyglycerides and surface lipids. A transmural trend in metabolites could be observed under these conditions. This trend, however, was likely to result from the interference of surface lipids in the epicardial layer. CONCLUSIONS: The authors demonstrate that the modified Fourier Series Window method can be applied in situations where signal-to-noise considerations limit the applicability of more sophisticated spatial localization methods. In addition, the authors report a slight gradient in the endogenous triacylglyceride resonance, which is likely to originate from the presence of surface lipids.

Animals↗

Sodium pentobarbital versus alpha-chloralose anesthesia. Experimental production of substantially different slopes in the transmural CP/ATP ratios within the left ventricle of the canine myocardium.

BACKGROUND: Transmural analyses of the creatine phosphate (CP)/ATP ratio in various lamina of the canine myocardium have previously revealed significant variations in the CP/ATP ratio, with the subendocardial layer displaying a decreased ratio relative to the subepicardial layer. Without exception, these results were obtained under sodium pentobarbital anesthesia. These findings have been interpreted to imply that the normal endocardium may be operating in the oxygen-limited domain or that there are transmurally varying set points for the regulation of oxidative phosphorylation. METHODS AND RESULTS: In this work, we examine the effect of the anesthetic regimen on the transmural CP/ATP ratio within the left ventricular wall of the canine myocardium using spatially localized 31P-nuclear magnetic resonance (NMR) and an open-chest model. Two anesthetics were compared, alpha-chloralose and sodium pentobarbital. Under sodium pentobarbital, the CP/ATP ratio ranged from 1.92 +/- 0.06 to 2.51 +/- 0.08 from endocardium to epicardium, resulting in a transmural slope in the CP/ATP ratio of 0.149 +/- 0.047 (n = 22). Under alpha-chloralose, CP/ATP ratios ranged from 2.18 +/- 0.05 to 2.32 +/- 0.06, with a transmural slope of 0.035 +/- 0.018 (n = 38). Thus, the transmural slope in CP/ATP ratio was nearly four times greater with sodium pentobarbital than with alpha-chloralose, and the difference in these slopes was statistically significant (P = .029). No difference was observed in average CP/ATP obtained from the entire wall with either anesthetic. CONCLUSIONS: These results demonstrate that the transmural trend in CP/ATP ratio previously reported in the myocardium is likely to be a direct reflection of the sodium pentobarbital anesthetic regimen, not truly reflecting the trend in the normal unanesthetized animal. Moreover, since the transmural variation in CP/ATP ratio was greatly reduced with alpha-chloralose, it appears unlikely that the endocardium in the normal unanesthetized heart is operating in the oxygen-limited domain. These results also point to the importance of the anesthetic regimen in biochemical analysis, indicate the necessity of increased caution in directly translating results obtained under anesthesia, and demonstrate the unique power of in vivo NMR to extract such subtle biochemical information.

Adenosine Triphosphate↗

3D echo planar imaging: application to the human head.

In this work, the authors present 3D images acquired from the human head using echo planar encoding for two of the three dimensions of k-space. The third dimension of k-space is filled by selecting and phase encoding a slab of spins as in conventional 3D steady state (GRASS based) acquisition regimens. Using this approach, a 128 x 64 x 64 3D data matrix could be obtained in 3.4-4.7 sec using effective TE values of 24 and 34 ms, respectively. High quality 3D images could be acquired once phase ghosts present on 2D images were minimized through proper adjustments of scanner hardware.

Brain↗

31P-nuclear magnetic resonance studies of chronic myocardial ischemia in the Yucatan micropig.

In this work, an x-irradiation/high fat/high cholesterol diet-induced atherogenic model was invoked to examine the effects of severe diffuse atherosclerosis on myocardial metabolism in the in vivo porcine heart. This model was studied using spatially localized 31P-nuclear magnetic resonance (NMR) to monitor pH and the levels of inorganic phosphate, phosphomonoesters, creatine phosphate, and adenosine triphosphate as a function of workload transmurally in control swine and in animals suffering from chronic ischemic heart disease. These preliminary studies revealed that the development of severe atherosclerosis and the accompanying chronically diseased state produce changes in high energy phosphates and that increases in rate pressure products result in demonstrable signs of ischemia in the myocardium which span the entire left ventricular wall. Ischemic changes include a global increase in inorganic phosphate and corresponding decreases in creatine phosphate, ATP, and pH. Importantly, changes in intracellular pH are noted with even the slightest increase in workload suggesting that these diseased hearts display elevated glycolytic activity. By challenging these animals with increased cardiac workload, we directly visualize how the chronically compromised heart responds to severe oxygen challenges in a clinically relevant model of this situation.

Animals↗

Torque free asymmetric gradient coils for echo planar imaging.

In this work, we present a new torque-free asymmetric gradient coil that is capable of generating high quality axial, sagittal, and coronal echo planar images of the human head. This gradient set was calculated using the Biot-Savart law and least square approaches to optimize the field in the region of interest and to minimize net torques. The resulting structure has excellent shoulder-to-coil clearance and, as such, has the advantage of providing good patient access to the linear portion of the gradient while minimizing patient discomfort from claustrophobia.

Echo-Planar Imaging↗

Dynamic 13C NMR analysis of oxidative metabolism in the in vivo canine myocardium.

Oxidative metabolism in the in vivo canine myocardium was studied noninvasively using 13C-enriched acetate and non-steady state 13C NMR techniques. Under low workload conditions, the myocardium oxidized the infused [2-13C]acetate and incorporated the labeled carbon into the glutamate pool as expected. This conclusion stems from the rapid enrichment of the C-2, C-3, and C-4 carbons of glutamic acid both under in vivo conditions and in extracts. Surprisingly, [2-13C]acetate uptake was not observed at high workloads as reflected by an absence of glutamate pool enrichment at these rate pressure products. Rather, the myocardium selected its substrate from an endogenous pool. Since free acetate can directly cross the inner mitochondrial membrane and be converted to acetyl-CoA through acetyl-CoA synthetase, these results support workload-dependent regulation of substrate access to the mitochondrial CoASH pool. As such, we advance the hypothesis that the selection of substrate for condensation with CoASH and subsequent oxidation in the tricarboxylic acid cycle is regulated kinetically through the Km values of the appropriate condensation enzymes and through the absolute levels of free CoASH in the mitochondria.

Animals↗