Gastrointestinal: bowel perforation by a foreign body.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to A M Groves.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
BACKGROUND: The relationship between the shuttle walk test and peak oxygen consumption in patients with lung cancer has not previously been reported. A study was undertaken to examine this relationship in patients referred for lung cancer surgery to test the hypothesis that the shuttle walk test would be useful in this clinical setting. METHODS: 125 consecutive patients with potentially operable lung cancer were prospectively recruited. Each performed same day shuttle walking and treadmill walking tests. RESULTS: Shuttle walk distances ranged from 104 m to 1020 m and peak oxygen consumption ranged from 9 to 35 ml/kg/min. The shuttle walk distance significantly correlated with peak oxygen consumption (r = 0.67, p<0.001). All 55 patients who achieved more than 400 m on the shuttle test had a peak oxygen consumption of at least 15 ml/kg/min. Seventy of 125 patients failed to achieve 400 m on the shuttle walk test; in 22 of these the peak oxygen consumption was less than 15 ml/kg/min. Nine of 17 patients who achieved less than 250 m had a peak oxygen consumption of more than 15 ml/kg/min. CONCLUSION: The shuttle walk is a useful exercise test to assess potentially operable lung cancer patients with borderline lung function. However, it tends to underestimate exercise capacity at the lower range compared with peak oxygen consumption. Our data suggest that patients achieving 400 m on the shuttle walk test do not require formal measurement of oxygen consumption. In patients failing to achieve this distance we recommend assessment of peak oxygen consumption, particularly in those unable to walk 250 m, because a considerable proportion would still qualify for surgery as they had an acceptable peak oxygen consumption.
AIMS: To test the hypothesis that the improved resolution afforded by 16-detector computed tomography (CT) would translate to better stress fracture detection when compared with skeletal scintigraphy. MATERIALS AND METHODS: Thirty-three cases of suspected stress fractures in 26 patients were investigated using skeletal scintigraphy and 16-detector CT performed on the same day. Planar images of the lower limbs were taken 3h post-injection of 400MBq (99m)Tc-methylene diphosphonate ((99m)Tc-MDP). (99m)Tc-MDP uptake was quantified at suspected fracture sites. CT was performed using a 16-detector multisection machine employing 0.75mm detectors and images reconstructed in 0.5mm increments. Examinations were reported independently and discordant results were compared at follow-up. RESULTS: At initial reporting scintigraphy identified fractures in 13 of the 33 cases and CT identified four of the 33. In one case, on review of the CT images, a fracture was present in the distal fibula that was not initially identified. This resulted in eight scintigraphic-positive CT-negative discordant cases. The (99m)Tc-MDP uptake was significantly lower in the discordant fracture group compared with the concordant group (p<0.01). CONCLUSIONS: Despite technological advances in CT, scintigraphy appeared to detect more stress fractures. As such, multidetector CT should not be used as a routine initial investigation in stress fracture detection. The potential use of (99m)Tc-MDP quantification at fracture sites is of interest and may be worth further investigation.
Blood pressure, heart rate, and oxygen saturation were monitored prospectively during 40 echocardiography recordings on 17 preterm infants (25-29 weeks; 510-1430 g), to examine whether echocardiography can be performed without disturbing cardiorespiratory status in preterm infants. There was no impact on absolute blood pressure. Heart rate increased by a mean of 4 beats per minute, and oxygen saturation decreased by a mean of 1% during echocardiography. While these changes reached statistical significance they are not of clinical significance as they remained well within ranges seen during control rest periods. All readings had greater minute-to-minute variability during echocardiography but differences were small and again remained within physiological ranges.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The British Thoracic Society and American College of Chest Physician guidelines outline criteria for investigating patients for lung cancer surgery. However, the guidelines are based on relatively old studies. Therefore, the relationship between pulmonary function test results and surgical outcome were studied prospectively in a large cohort of lung cancer patients. From January 2001 to December 2003, 110 patients underwent surgery for lung cancer. All underwent full lung function testing in order to predict post-operative lung function. The hospital mortality rate was 3% and major complication rate 22%. There was poor overall outcome in 13%. Mean pre-operative lung function values were: forced expiratory volume in one second (FEV1) 2.0 L (79.4% of the predicted value), and carbon monoxide diffusing capacity of the lung (D(L,CO)) 73.6% pred. The mean post-operative lung function values were: FEV1 1.4 L (55.6% pred), and D(L,CO) 51.3% pred. All lung function values were better predictors of poor surgical outcome when expressed as a percentage of the predicted value. Using a threshold of pre-operative FEV1 of 47% pred resulted in the most useful positive and negative predictive probabilities, 0.90 and 0.67, respectively. Lung function values expressed as a percentage of the predicted value are more useful predictors of post-operative outcome than absolute values. The threshold of predicted forced expiratory volume in one second for surgical intervention could be lower (45-50% pred) than is currently accepted without increased mortality.
To compare the measured uptake of 99Tcm-methylene diphosphonate (99Tcm-MDP) in those scaphoid fractures seen on both 16 detector multislice CT and scintigraphy, with those seen only on scintigraphy. Over a 12 month period a total of 51 patients with suspected fracture underwent both conventional 99Tcm-MDP scintigraphy and 16 detector multislice CT on the same day. The 99Tcm-MDP uptake was then quantified in patients with identified fracture. This was measured by placing a region of interest (ROI) over the fracture site and the mean and maximum number of counts were compared with those in a similar size ROI placed over background bone activity. A total of 23 fractures were identified on scintigraphy of which 16 were also detected on CT (concordant). In seven cases the fracture was not seen on CT, even in retrospect (discordant). In the discordant cases, follow-up radiographs and MRI (where available) also failed to demonstrate a fracture. The mean fracture count to background bone activity ratio averaged 7.7 (range 3.2-18.5) for concordant fractures and 3.8 (range 1.7-5.3) for discordant fractures (t-test p=0.04). The maximum fracture count to background bone activity ratio averaged 12.7 (range 4.3-27.7) for concordant fractures and 6.3 (range 2.6-9.5) for discordant fractures (t-test p=0.03). It is speculated whether these discordant fractures with less 99Tcm-MDP uptake may represent a less severe injury such as bone bruise.
99Tcm-mercaptoacetyltriglycine (MAG3) renogram is a robust imaging technique used to delineate upper urinary tract obstruction. The changes observed on the renogram are often reversible on relief of obstruction. We present two cases illustrating the extreme consequence of contrast nephrotoxicity on pre-existing obstructed kidneys. In one case, this led to severe impairment of perfusion and uptake observed on 99Tcm-MAG3 renogram and in the second case virtual non-visualization of the obstructed kidney. Subsequent treatment of obstruction, led to dramatic improvement in renal function. It is important for clinicians, nuclear medicine physicians and radiologists to be aware of the potential of contrast nephrotoxicity in obstructed kidneys.
We discuss a case of a 19-year-old man with scaphoid trauma. We describe the imaging findings on three sets of radiographs, bone scintigraphy, CT and MRI. CT failed to identify a scaphoid fracture, which was present on 6 week radiographs, MRI and scintigraphy. The case illustrates that despite multidetector technology, CT still relies upon cortical and or trabecular displacement to demonstrate fractures.
AIM: To assess whether the early regurgitation of intravenous contrast medium into the inferior vena cava (IVC) and/or hepatic veins on computed tomography (CT), indicates tricuspid regurgitation (TR), and if so, whether it be used to grade severity. MATERIALS AND METHODS: We identified 86 consecutive patients that had been investigated for possible pulmonary endarterectomy at Papworth Hospital. From these, 61 patients were selected in whom CT, transthoracic echocardiography, and right heart catheterization (RHC) had been performed within 6 weeks. Using an arbitrary visual scale, the degree of TR assessed by intravenous contrast-enhanced CT was compared with echocardiography. Results were analysed using a kappa weighted statistical test. In addition, CT and echocardiographic assessments of TR severity were correlated with pulmonary artery pressure measurements obtained by RHC (Spearman's rank correlation coefficient). RESULTS: CT assessment of TR had a sensitivity of 90.4% and a specificity of 100% in detecting echocardiographic TR. For TR graded as more than trivial by echocardiography, sensitivity of CT was 100%. With respect to RHC data, the correlation between severity assessment of TR between CT and echocardiography using the Kappa weighted coefficient was 0.56 (moderately good agreement). With respect to RHC data, the correlation between mean pulmonary pressure and TR grading on CT and echocardiography was r = 0.685 (p < 0.001) and r = 0.727 (p < 0.001), respectively. CONCLUSION: Early opacification of the IVC or hepatic veins on first-pass contrast-enhanced CT almost invariably indicates TR. There is moderately good agreement between CT and echocardiographic assessment of the severity of TR. Both CT and echocardiographic grading of TR correlate well with RHC measurements of pulmonary artery pressure.
AIM: To evaluate the whether screening for cerebral metastases in neurologically intact patients with potentially resectable non-small cell lung cancer patients is both worthwhile and cost-effective. METHODS: We prospectively performed computed tomography (CT) of the head in 105 consecutive patients with potentially resectable lung cancer over an 18-month period. None of these patients had neurological symptoms or signs. RESULTS: Five patients (4.8%) with cerebral metastases were identified using CT. At our institution the financial saving of avoiding five thoracotomies was pound sterling 45,000, whilst the cost of performing 105 head CTs was pound sterling 16,000. This represented a substantial saving for the healthcare provider and preserved the quality of life in five patients. CONCLUSIONS: We conclude that screening for cerebral metastases in neurologically intact patients with potentially resectable non small cell lung cancer patients is both worthwhile and cost effective.
Computer simulations are widely used to estimate effective doses from CT examinations. The raw data often used in their estimations were obtained some years ago and made certain assumptions regarding CT unit design. At that time multidetector CT units were unavailable. Changes in design will limit the accuracy of computer simulated dosimetry on these machines. We therefore estimated CT dose on a 16-detector unit directly using thermoluminescent dosemeters (TLDs) and an anthropomorphic phantom. We found that the dose measured directly was 18% higher than the computer simulated dosimetry, in keeping with the previously recognised underestimation by computer simulation techniques compared with TLD measurements.
Pulmonary arteriovenous malformations (PAVMs) are rare. We discuss a case of an 81-year-old female who attended hospital with a haemothorax. Ultrasound not only demonstrated an echogenic effusion in the right pleural space, but also identified an associated tubular structure. Doppler was applied to this structure, which exhibited pulsatile flow. This raised the possibility of a PAVM, which was subsequently confirmed on CT and angiography. Although, PAVM is a rare cause of haemothorax, the diagnosis should still be considered and transpleural ultrasound can detect these malformations non-invasively by the bedside.
Explore the source record for details and available documents.