PubMed Health⌕ Search

Biomedical subjects

A M Howseman

Publications and source records attributed to A M Howseman.

16 recordsLinked to original sources

Characterization and correction of interpolation effects in the realignment of fMRI time series.

Subject motion in functional magnetic resonance imaging (fMRI) studies can be accurately estimated using realignment algorithms. However, residual changes in signal intensity arising from motion have been identified in the data even after realignment of the image time series. The nature of these artifacts is characterized using simulated displacements of an fMRI image and is attributed to interpolation errors introduced by the resampling inherent within realignment. A correction scheme that uses a periodic function of the estimated displacements to remove interpolation errors from the image time series on a voxel-by-voxel basis is proposed. The artifacts are investigated using a brain phantom to avoid physiological confounds. Small- and large-scale systematic displacements show that the artifacts have the same form as revealed by the simulated displacements. A randomly displaced phantom and a human subject are used to demonstrate that interpolation errors are minimized using the correction.

Algorithms↗

Variability in fMRI: an examination of intersession differences.

The results from a single functional magnetic resonance imaging session are typically reported as indicative of the subject's functional neuroanatomy. Underlying this interpretation is the implicit assumption that there are no responses specific to that particular session, i.e., that the potential variability of response between sessions is negligible. The present study sought to examine this assumption empirically. A total of 99 sessions, comprising 33 repeats of simple motor, visual, and cognitive paradigms, were collected over a period of 2 months on a single male subject. For each paradigm, the inclusion of session-by-condition interactions explained a significant amount of error variance (P < 0.05 corrected for multiple comparisons) over a model assuming a common activation magnitude across all sessions. However, many of those voxels displaying significant session-by-condition interactions were not seen in a multisession fixed-effects analysis of the same data set; i.e., they were not activated on average across all sessions. Most voxels that were both significantly variable and activated on average across all sessions did not survive a random-effects analysis (modeling between-session variance). We interpret our results as demonstrating that correct inference about subject responses to activation tasks can be derived through the use of a statistical model which accounts for both within- and between-session variance, combined with an appropriately large session sample size. If researchers have access to only a single session from a single subject, erroneous conclusions are a possibility, in that responses specific to this single session may be claimed to be typical responses for this subject.

Adult↗

Functional magnetic resonance imaging: imaging techniques and contrast mechanisms.

Functional magnetic resonance imaging (fMRI) is a widely used technique for generating images or maps of human brain activity. The applications of the technique are widespread in cognitive neuroscience and it is hoped they will eventually extend into clinical practice. The activation signal measured with fMRI is predicated on indirectly measuring changes in the concentration of deoxyhaemoglobin which arise from an increase in blood oxygenation in the vicinity of neuronal firing. The exact mechanisms of this blood oxygenation level dependent (BOLD) contrast are highly complex. The signal measured is dependent on both the underlying physiological events and the imaging physics. BOLD contrast, although sensitive, is not a quantifiable measure of neuronal activity. A number of different imaging techniques and parameters can be used for fMRI, the choice of which depends on the particular requirements of each functional imaging experiment. The high-speed MRI technique, echo-planar imaging provides the basis for most fMRI experiments. The problems inherent to this method and the ways in which these may be overcome are particularly important in the move towards performing functional studies on higher field MRI systems. Future developments in techniques and hardware are also likely to enhance the measurement of brain activity using MRI.

Brain↗

Rapid T2* mapping using interleaved echo planar imaging.

Magnetic resonance imaging methods that are sensitive to T2* are widely used in the study of blood oxygenation changes, most notably in functional studies of the brain. In these studies the signal intensity change in T2*-weighted imaging is related to the coupling of cerebral blood flow and metabolism. Rapid measurement of T2* itself would offer a valuable method to quantify blood oxygenation changes indirectly and monitor their time course. An interleaved echoplanar imaging (EPI) sequence is presented here that allows maps of T2* to be generated in a few seconds. The sequence benefits from reduced geometric distortion and an improved point spread function compared with single-shot EPI. A comparison among a set of T2*-weighted interleaved EPI images, single-shot EPI, and conventional gradient-echo and spin-echo methods is made using a compartmentalized doped water phantom. The interleaved sequence yields accurate T2* values when compared with reference measurements made using the slower gradient-echo technique. Data acquired from the rat brain at 2.35 T prior to and during an anoxic challenge show, with high temporal resolution, the reduction in T2* associated with increased levels of deoxyhemoglobin.

Animals↗

Implementation of quantitative FAIR perfusion imaging with a short repetition time in time-course studies.

Flow-sensitive alternating inversion recovery (FAIR) is a pulsed arterial spin labeling magnetic resonance imaging method for perfusion quantification. In its standard implementation for quantification with full longitudinal relaxation between acquisitions, its use in time-course investigations of rapidly changing flow values is limited. The time efficiency can be improved by decreasing the repetition time but quantification becomes problematic. This situation is further complicated if a whole-body radiofrequency transmit coil is not used since fresh blood spins will flow in from outside the coil. To alleviate these problems, the use of global pre-saturation is proposed. The resulting expression for the flow signal depends on the relationship between the imaging parameters and the coil inflow time and can be significantly simplified under certain combinations of these parameters. With this implementation of FAIR, quantitative flow maps of gerbil brains were obtained with a 3 minute time resolution in a study of the effects of reperfusion. The pre-occlusion flow measurements were in good agreement with values obtained by the standard FAIR implementation and by other techniques, but the low values following occlusion were underestimated due to the increased transit times.

Animals↗

The effect of slice order and thickness on fMRI activation data using multislice echo-planar imaging.

Multislice echo-planar imaging (EPI) is a commonly used technique for fMRI studies. Brain activation images acquired using fMRI are sensitive to T2* changes, reflecting the level of blood oxygenation (BOLD contrast), and may also contain an element of T1 contrast which detects blood flow changes in large vessels. If slice inflow (T1) effects are significant in multislice EPI, then as the order in which the slices are acquired is changed, differences in the activation maps are predicted. However, in experiments presented here using visual stimulation, the data demonstrate that highly consistent results can be achieved for repetition times (TR) of 6.0, 3.0, and 1.5 s. This suggests that, for whole-brain multislice EPI, fMRI activation is dominated by T2*, BOLD contrast. The thickness of the imaging slice is also an important parameter in these studies, having implications for spatial resolution, sensitivity, and acquisition time. In separate visual cortex experiments the effect on the values of the fMRI Z scores and the number of activated voxels is investigated as a function of slice thickness (from 1 to 8 mm). The maximum Z scores in the data are similar for all slice thicknesses and, after resampling to allow a direct comparison to be made, the volume of visual cortex detected as significantly activated increases with slice thickness.

Brain Mapping↗

A specific role for the thalamus in mediating the interaction of attention and arousal in humans.

The physiological basis for the interaction of selective attention and arousal is not clearly understood. Here we present evidence in humans that specifically implicates the thalamus in this interaction. We used functional magnetic resonance imaging to measure brain activity during the performance of an attentional task under different levels of arousal. Activity evoked in the ventrolateral thalamus by the attentional task changed as a function of arousal. The highest level of attention-related thalamic activity is seen under conditions of low arousal (secondary to sleep deprivation) compared with high arousal (secondary to caffeine administration). Other brain regions were also active during the attentional task, but these areas did not change their activity as a function of arousal. Control experiments establish that this pattern of changes in thalamic activity cannot be accounted for by nonspecific effects of arousal on cerebral hemodynamics. We conclude that the thalamus is involved in mediating the interaction of attention and arousal in humans.

Adult↗

Blood oxygenation level dependent signal time courses during prolonged visual stimulation.

Previous functional magnetic resonance imaging (MRI) studies using extended visual stimulation have reported disparate results. Two studies have shown that blood oxygen level dependent (BOLD) contrast decays over time which is cited as evidence of recoupling between oxygen utilisation and cerebral blood flow during stimulus presentation. These findings have serious implications for the design of functional MRI experiments because they raise the possibility that BOLD contrast may not accurately reflect neuronal activity. Another study reported no decay of BOLD contrast. These studies used different visual stimuli and imaging techniques. We have performed a series of experiments, using different MRI techniques (echo-planar imaging and fast low angle shot) and two different visual stimuli to assess which of these factors may explain the previous results. In all of our experiments the signal time course from areas of significant activation remained largely elevated throughout the duration of stimulation and this is not affected by the imaging method used. Our data, in accordance with that of Bandettini et al., suggest that recoupling between blood flow and oxygen extraction is not a general phenomenon in the human brain when visual stimuli are presented for an extended time.

Adult↗

1H-[13C] NMR measurements of [4-13C]glutamate turnover in human brain.

A limitation of previous methods for studying human brain glucose metabolism, such as positron emission tomography, is that metabolic steps beyond glucose uptake cannot be studied. Nuclear magnetic resonance (NMR) has the advantage of allowing the nondestructive measurement of 13C distribution in specific carbon positions of metabolites. In this study 1H-[13C] NMR spectroscopy in conjunction with volume localization was used to measure the rate of incorporation of 13C isotope from infused enriched [1-13C]glucose to human brain [4-13C]glutamate. In three studies C4 glutamate turnover time constants of 25, 20, and 17 min were measured in a 21-cm3 volume centered in the region of the visual cortex. Based on an analysis of spectrometer sensitivity the spatial resolution of the method can be improved to < 4 cm3. In conjunction with metabolic modeling and other NMR measurements this method can provide a measure of regional rates of the brain tricarboxylic acid cycle and other metabolic pathways.

Brain↗

Proton magnetic resonance spectroscopy of cerebral lactate and other metabolites in stroke patients.

BACKGROUND AND PURPOSE: Proton magnetic resonance spectroscopy can measure in vivo brain lactate and other metabolites noninvasively. We measured the biochemical changes accompanying stroke in 16 human subjects with cortical or deep cerebral infarcts within the first 3 weeks after symptom onset, and performed follow-up studies on six. METHODS: One-dimensional proton spectroscopic imaging encompassing the infarct region was performed with a 2.1-T whole-body magnet using the stimulated echo pulse sequence and an echo time of 270 msec. RESULTS: All but one of the cortical stroke patients had increased lactate within or near the infarct. Persistently elevated cerebral lactate was documented in five of six cases studied serially as long as 251 days after infarction. N-acetylaspartate levels were decreased in most cortical strokes. Elevated lactate, accompanied by minimal reduction in N-acetylaspartate, was recorded in two of four patients in the first week following a small subcortical infarct. CONCLUSIONS: Long-term elevation of lactate commonly occurs after stroke. This lactate may arise from ongoing ischemia or infiltrating leukocytes, or it may be a residual of the lactate formed during the initial insult. The ability to observe stroke-elevated lactate pools at any time after lesion onset provides an approach to distinguishing among these possibilities in the future.

Aspartic Acid↗

Assignment of the 1H chemical shifts of glycogen.

Assignments of nearly all the 1H chemical shifts of glycogen are made by 2-D 1H-1H homonuclear and 13C-1H heteronuclear COSY. We demonstrated that it is possible to obtain well-resolved 2-D n.m.r. spectra for a large molecule like glycogen. The seven nonequivalent protons of the glucose residues in the alpha-(1----4)-linked chains, and of those at the nonreducing ends, were completely assigned. Distinct chemical shifts for H-1 and H-2 immediately adjacent to the alpha-(1----6) bonds at the branch points were also determined. Several modifications of previous 13C chemical shift assignments were made from the heteronuclear 2-D n.m.r. data.

Animals↗

Localized proton NMR observation of [3-13C]lactate in stroke after [1-13C]glucose infusion.

To assess whether elevated lactate in stable stroke is being actively produced from blood glucose localized 1H NMR stimulated echo spectra were obtained from a patient in the region of a 32-day-old cortical infarct before and 60-100 min after infusion of [1-13C]glucose. Prior to the infusion the spectrum from the region of the infarct contained an elevated resonance from C3 lactate and a greatly reduced resonance from N-acetyl groups relative to an unaffected contralateral region. After the infusion two additional resonances were observed at 62 and -64 Hz relative to the unlabeled resonance of C3 lactate which were assigned on the basis of chemical shift and relative intensity to [3-13C]lactate. The [3-13C]lactate fractional enrichment in the infarct region was measured to be 32% which is within error one-half the average [1-13C]plasma glucose enrichment during the postinfusion NMR measurement. The result suggests that the stroke lactate pool was completely derived from infused glucose.

Blood Glucose↗

Study of internal structure of the human fetus in utero by echo-planar magnetic resonance imaging.

The ultrafast echo-planar magnetic resonance imaging technology, developed and built in Nottingham, has been used to produce the first snapshot images of the human fetus in utero. The imager, operating at a proton resonance frequency of 22 MHz, produces transaxial views in 64 or 128 milliseconds. These images comprise either 64 x 128 or 128 x 128 pixels with an in-plane resolution of 3 x 3 mm2. The slice thickness is 10 mm. Fetal scans of up to 32 contiguous slices are produced in a few minutes. These have been used to study the internal structure of the uterus and the fetus in a range of cases with gestations ranging from 26 weeks to term. Echo-planar imaging seems particularly suitable as an imaging modality since its high speed obviates image blurring arising from fetal motion.

Fetal Diseases↗

Whole-body echo-planar MR imaging at 0.5 T.

The ultra-high-speed echo-planar imaging technique produces instant snapshot magnetic resonance images in exposure times ranging from approximately 10 to 100 msec. A particular variant, the modulus blipped echo-planar single-pulse technique (MBEST), possesses two advantages: First, it makes the technique experimentally more robust; second, it introduces inherent T2 weighting in the images. The authors have used MBEST with an exposure time of 64 msec to explore the potential range of clinical applications in a series of normal volunteers. Applications include evaluation of the heart, renal function, and gastrointestinal tract. All images were obtained with proton resonances at 22 MHz.

Abdomen↗

Gastrointestinal tract: dynamic MR studies with echo-planar imaging.

Gastrointestinal (GI) tract motility was depicted in four human volunteers with the high-speed echo-planar imaging technique: modulus blipped echo-planar single-pulse technique (MBEST). Data acquisition times of 64 and 128 msec obviate image degradation due to motion without the need for gut paralysis and allow imaging of the GI tract in real time. Peristaltic patterns of the gastric antrum and proximal small intestine were depicted for fasting and fed subjects and subjects in whom peristalsis had been pharmacologically stimulated. The potential for quantitative measurements of GI tract motion with this new technique was demonstrated.

Adult↗

Improvements in snap-shot nuclear magnetic resonance imaging.

New variants of the ultra-high-speed echo-planar imaging technique have been used to obtain snap-shot images of adult patients and volunteers at 0.1 T. Modified pulsed-gradient sequences together with non-linear signal sampling and activity screened gradients have greatly improved the image quality obtainable by single-shot methods. A particular variant, modulus blipped echo-planar single-pulse technique (MBEST), although slightly slower than the blipped echo-planar single-pulse technique (BEST), is experimentally more robust and incorporates intrinsic T2 weighting. An account of these improvements together with some experimental results is presented.

Adult↗